Shannah Secret
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shannah Secret has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Richard Mayne
University of Oxford
4 shared publications - Heli Harvala
National Health Service Blood and Transplant, London, United Kingdom
3 shared publications Peter Simmonds
Institute of Biomedicine University of Turku and University Hospital Turku Turku Finland
3 shared publications- Tanya Golubchik
School of Medical Sciences and Sydney Infectious Diseases Institute, Faculty of Medicine and Health, The University of Sydney, Camperdown, New South Wales 2006, Australia
3 shared publications Chris Kent
Institute of Microbiology and Infection University of Birmingham Birmingham UK
2 shared publicationsGeorge Airey
Nuffield Department of Medicine University of Oxford Oxford UK
2 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Wiley in Journal of Medical Virology
- Vol. 98 (9)
Next‐Generation Sequencing Methods for Sensitive Hepatitis B Viral Genome Analysis: A European Study
This multicentre study investigated the utility of next‐generation sequencing (NGS) to detect and generate hepatitis B virus (HBV) genomes in samples of low viral load (from 0.2 to 6207 IU/mL). 23 HBV DNA‐positive plasma samples of genotypes A‐E and one HBV‐negative control sample were assayed blindly via 9 established NGS methods from 6 European laboratories. Methods included untargeted metagenomics, pre‐enrichment by probe‐capture followed by Illumina sequencing, and HBV‐specific PCR pre‐amplification followed by sequencing with Nanopore or Illumina. Full HBV genomes were obtained only from samples with viral loads > 1000 IU/mL using probe‐capture methods, > 200 IU/mL using PCR‐Illumina methods, > 10 IU/mL using PCR‐Nanopore methods, and in no samples using metagenomic methods. Contamination was observed in the negative control and samples with very low viral loads in PCR‐based methods. Probe‐capture and metagenomic methods detected additional viruses not routinely screened in blood donations, including polyomaviruses and herpesviruses; positive results were confirmed by PCR. In conclusion, NGS may delineate whole‐genome sequences at low viral loads if supported by a PCR pre‐amplification step. Probe‐capture methods also reliably detect HBV without pre‐amplification but show limited genome coverage for samples with low viral loads; they may additionally detect a wide range of blood‐borne viruses.
- 2 September 2026
- Published by Wiley in Journal of Medical Virology
- Vol. 98 (9)
Open AccessNext‐Generation Sequencing Methods for Sensitive Hepatitis B Viral Genome Analysis: A European Study
This multicentre study investigated the utility of next‐generation sequencing (NGS) to detect and generate hepatitis B virus (HBV) genomes in samples of low viral load (from 0.2 to 6207 IU/mL). 23 HBV DNA‐positive plasma samples of genotypes A‐E and one HBV‐negative control sample were assayed blindly via 9 established NGS methods from 6 European laboratories. Methods included untargeted metagenomics, pre‐enrichment by probe‐capture followed by Illumina sequencing, and HBV‐specific PCR pre‐amplification followed by sequencing with Nanopore or Illumina. Full HBV genomes were obtained only from samples with viral loads > 1000 IU/mL using probe‐capture methods, > 200 IU/mL using PCR‐Illumina methods, > 10 IU/mL using PCR‐Nanopore methods, and in no samples using metagenomic methods. Contamination was observed in the negative control and samples with very low viral loads in PCR‐based methods. Probe‐capture and metagenomic methods detected additional viruses not routinely screened in blood donations, including polyomaviruses and herpesviruses; positive results were confirmed by PCR. In conclusion, NGS may delineate whole‐genome sequences at low viral loads if supported by a PCR pre‐amplification step. Probe‐capture methods also reliably detect HBV without pre‐amplification but show limited genome coverage for samples with low viral loads; they may additionally detect a wide range of blood‐borne viruses.
- Open Access
- 27 July 2026
- Published by Wiley in Journal of Medical Virology
- Vol. 98 (8)
A Snapshot of the UK Blood Donor Plasma Virome: A Retrospective Cross‐Sectional Cohort Study
Estimates of population prevalence and genetic diversity of bloodborne viruses in healthy humans are essential to support population‐scale monitoring for transfusion transmission risk. In the UK and globally, blood donations are routinely screened for a limited number of high‐consequence pathogens, but the full composition of the plasma virome remains to be characterized. Using a novel quantitative targeted metagenomics sequencing approach, we analyzed previously unscreened plasma donations collected by NHS Blood and Transplant in England for all major pathogenic and known commensal human bloodborne viruses, and quantified their viral burden. Here we show that in a representative sample of 5064 UK blood donors in pools of 24 collected over a 1‐month period, the virome was dominated by a small number of largely persistent species, representing < 10% (10/106) of previously identified human bloodborne viruses. The principal genera of human anelloviruses (TTV, TTMV and TTMDV) were detected in 89% of pools, albeit at low read count, inconsistent with measured anellovirus viral loads. In contrast, human pegivirus type 1 (HPgV‐1), had an estimated population prevalence of 3.7% (95% CI 3.0%–4.4%), with high read count and complete genome recovery in around one half of positive pools, consistent with high titer in plasma. Less common detections included one species of gemykibovirus in five separate plasma pools, one hepatitis C virus (genotype 1a), and polyomaviruses and herpesviruses with prevalences between 0.04% (parvovirus 4, BK polyomavirus) to 0.41% (human herpesvirus 6). Phylogenetic analyses revealed mixed TTV, TTMV, and TTMDV populations and almost exclusively genotype 2 HPgV‐1, consistent with known genotype distributions in Europe. Our results provide a baseline for describing the healthy plasma virome in UK blood donors.
- 27 July 2026
- Published by Wiley in Journal of Medical Virology
- Vol. 98 (8)
Open AccessA Snapshot of the UK Blood Donor Plasma Virome: A Retrospective Cross‐Sectional Cohort Study
Estimates of population prevalence and genetic diversity of bloodborne viruses in healthy humans are essential to support population‐scale monitoring for transfusion transmission risk. In the UK and globally, blood donations are routinely screened for a limited number of high‐consequence pathogens, but the full composition of the plasma virome remains to be characterized. Using a novel quantitative targeted metagenomics sequencing approach, we analyzed previously unscreened plasma donations collected by NHS Blood and Transplant in England for all major pathogenic and known commensal human bloodborne viruses, and quantified their viral burden. Here we show that in a representative sample of 5064 UK blood donors in pools of 24 collected over a 1‐month period, the virome was dominated by a small number of largely persistent species, representing < 10% (10/106) of previously identified human bloodborne viruses. The principal genera of human anelloviruses (TTV, TTMV and TTMDV) were detected in 89% of pools, albeit at low read count, inconsistent with measured anellovirus viral loads. In contrast, human pegivirus type 1 (HPgV‐1), had an estimated population prevalence of 3.7% (95% CI 3.0%–4.4%), with high read count and complete genome recovery in around one half of positive pools, consistent with high titer in plasma. Less common detections included one species of gemykibovirus in five separate plasma pools, one hepatitis C virus (genotype 1a), and polyomaviruses and herpesviruses with prevalences between 0.04% (parvovirus 4, BK polyomavirus) to 0.41% (human herpesvirus 6). Phylogenetic analyses revealed mixed TTV, TTMV, and TTMDV populations and almost exclusively genotype 2 HPgV‐1, consistent with known genotype distributions in Europe. Our results provide a baseline for describing the healthy plasma virome in UK blood donors.
- Open Access
- 7 April 2026
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 14 (4) , e0250025
Bioinformatic identification of lentivirus transfer plasmid contamination causing false-positive HIV NAT results in a high-throughput molecular screening laboratory
Blood screening programs require ultra-sensitive high-throughput PCRs to ensure the absence of pathogens to keep blood components safe for recipients. We present here details of an investigation wherein samples undergoing screening using a high-throughput multi-pathogen NAT assay began to exhibit an abnormally high HIV false reactivity rate. NHS Blood and Transplant usually sees up to 10 HIV reactive samples per year, but this increased to over 100 in just a few days. Investigations into the cause were imperative to prevent recurrence. Analyzer and reagent issues were ruled out and environmental swabbing revealed extensive contamination of the laboratory, with 356 of 392 swabs testing positive. We demonstrate the methods by which we used amplicon NGS and a custom bioinformatic approach to differentiate between expected amplicons, PCR artifact, and contaminant sequences from extracted false-positive samples. Our investigation was able to trace the source of contamination to an unexpected source, a lentivirus transfer plasmid, containing the long terminal repeat (LTR) region of HIV-1, from a neighboring laboratory. This incident demonstrates the risks of false reactivity from HIV-derived lentiviral vectors, which has also been seen in patients receiving lentiviral vectors as part of gene or CAR T-cell therapies. The nature of the contaminant meant that there was no risk to donors, recipients, or staff. It did, however, demonstrate the critical importance of facility design and operation in plasmid manufacturing sites to prevent the spread of such contaminants and avoid unexpected downstream consequences such as those encountered in the screening laboratory. IMPORTANCE: This paper describes a large-scale contamination incident that occurred at a critically important high-throughput screening laboratory resulting in a significant spike of positives in the HIV screening. We describe the use of NGS and a custom bioinformatics approach that enabled us to identify the unexpected source of the contamination—a lentivirus transfer plasmid, containing the long terminal repeat (LTR) region of HIV-1, being produced in a neighboring laboratory. This incident demonstrates the risks of false reactivity from HIV-derived lentiviral vectors, which has also been seen in patients receiving lentiviral vectors as part of gene or CAR T-cell therapies. The nature of the contaminant meant that there was no risk to donors, recipients, or staff. It did, however, demonstrate the critical importance of facility design and operation in plasmid manufacturing sites to prevent the spread of such contaminants and avoid unexpected downstream consequences such as those encountered in the screening laboratory.
- 7 April 2026
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 14 (4) , e0250025
Open AccessBioinformatic identification of lentivirus transfer plasmid contamination causing false-positive HIV NAT results in a high-throughput molecular screening laboratory
Blood screening programs require ultra-sensitive high-throughput PCRs to ensure the absence of pathogens to keep blood components safe for recipients. We present here details of an investigation wherein samples undergoing screening using a high-throughput multi-pathogen NAT assay began to exhibit an abnormally high HIV false reactivity rate. NHS Blood and Transplant usually sees up to 10 HIV reactive samples per year, but this increased to over 100 in just a few days. Investigations into the cause were imperative to prevent recurrence. Analyzer and reagent issues were ruled out and environmental swabbing revealed extensive contamination of the laboratory, with 356 of 392 swabs testing positive. We demonstrate the methods by which we used amplicon NGS and a custom bioinformatic approach to differentiate between expected amplicons, PCR artifact, and contaminant sequences from extracted false-positive samples. Our investigation was able to trace the source of contamination to an unexpected source, a lentivirus transfer plasmid, containing the long terminal repeat (LTR) region of HIV-1, from a neighboring laboratory. This incident demonstrates the risks of false reactivity from HIV-derived lentiviral vectors, which has also been seen in patients receiving lentiviral vectors as part of gene or CAR T-cell therapies. The nature of the contaminant meant that there was no risk to donors, recipients, or staff. It did, however, demonstrate the critical importance of facility design and operation in plasmid manufacturing sites to prevent the spread of such contaminants and avoid unexpected downstream consequences such as those encountered in the screening laboratory. IMPORTANCE: This paper describes a large-scale contamination incident that occurred at a critically important high-throughput screening laboratory resulting in a significant spike of positives in the HIV screening. We describe the use of NGS and a custom bioinformatics approach that enabled us to identify the unexpected source of the contamination—a lentivirus transfer plasmid, containing the long terminal repeat (LTR) region of HIV-1, being produced in a neighboring laboratory. This incident demonstrates the risks of false reactivity from HIV-derived lentiviral vectors, which has also been seen in patients receiving lentiviral vectors as part of gene or CAR T-cell therapies. The nature of the contaminant meant that there was no risk to donors, recipients, or staff. It did, however, demonstrate the critical importance of facility design and operation in plasmid manufacturing sites to prevent the spread of such contaminants and avoid unexpected downstream consequences such as those encountered in the screening laboratory.
- Open Access
- 9 March 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (6) , 770-778
Pre‐exposure prophylaxis use in blood donors in England
Background and Objectives: The For the Assessment of Individualized Risk (FAIR) framework, introduced by NHS Blood and Transplant (NHSBT) in 2021, aims to reduce stigma and improve equity in blood donor selection, particularly for gay, bisexual and other men who have sex with men (GBMSM). While pre‐exposure prophylaxis (PrEP) is highly effective at preventing sexual transmission of human immunodeficiency virus, its declared use excludes individuals from blood donation. This study examined PrEP use among male blood donors with current or past syphilis in England to evaluate guideline compliance and implications for blood safety. Materials and Methods: Residual plasma samples from syphilis‐positive male blood donors collected in 2023 were tested for PrEP. These data were combined with two previous studies of syphilis‐positive donors conducted between July 2018 and June 2024, incorporating demographics and reported PrEP use. Results: The rate of syphilis‐positive blood donations increased from 4.09 to 10.32 per 100,000 donations between 2018 and 2024 ( p = 0.048, Mann–Kendall trend test) with a rising proportion of past syphilis cases attributed to GBMSM (18%–37%; p = 0.004, Fisher's test, p = 0.001 Mann–Kendall test); 7.1% of syphilis‐positive blood samples from male blood donors tested positive for PrEP in 2023, indicating frequent non‐compliance with donation guidelines. Conclusion: Persistent PrEP use among syphilis‐positive donors since 2018 suggests gaps in donor education regarding eligibility. Targeted public health interventions, particularly for younger GBMSM, are needed to strengthen sexual health education, PrEP messaging and awareness of donation criteria. Further research into other infections associated with high‐risk sexual behaviour is warranted.
- 9 March 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (6) , 770-778
Open AccessPre‐exposure prophylaxis use in blood donors in England
Background and Objectives: The For the Assessment of Individualized Risk (FAIR) framework, introduced by NHS Blood and Transplant (NHSBT) in 2021, aims to reduce stigma and improve equity in blood donor selection, particularly for gay, bisexual and other men who have sex with men (GBMSM). While pre‐exposure prophylaxis (PrEP) is highly effective at preventing sexual transmission of human immunodeficiency virus, its declared use excludes individuals from blood donation. This study examined PrEP use among male blood donors with current or past syphilis in England to evaluate guideline compliance and implications for blood safety. Materials and Methods: Residual plasma samples from syphilis‐positive male blood donors collected in 2023 were tested for PrEP. These data were combined with two previous studies of syphilis‐positive donors conducted between July 2018 and June 2024, incorporating demographics and reported PrEP use. Results: The rate of syphilis‐positive blood donations increased from 4.09 to 10.32 per 100,000 donations between 2018 and 2024 ( p = 0.048, Mann–Kendall trend test) with a rising proportion of past syphilis cases attributed to GBMSM (18%–37%; p = 0.004, Fisher's test, p = 0.001 Mann–Kendall test); 7.1% of syphilis‐positive blood samples from male blood donors tested positive for PrEP in 2023, indicating frequent non‐compliance with donation guidelines. Conclusion: Persistent PrEP use among syphilis‐positive donors since 2018 suggests gaps in donor education regarding eligibility. Targeted public health interventions, particularly for younger GBMSM, are needed to strengthen sexual health education, PrEP messaging and awareness of donation criteria. Further research into other infections associated with high‐risk sexual behaviour is warranted.
- Open Access
Next-Generation Sequencing Methods for Sensitive Hepatitis B Viral Genome Analysis: A European Study
Objectives: This multicentre study investigated the utility of next-generation sequencing (NGS) to detect and generate hepatitis B virus (HBV) genomes in samples of low viral load (from 0.2 to 6207 IU/ml). Methods: 23 HBV DNA positive plasma samples of genotypes A-E and one HBV-negative control sample were assayed blindly via 9 established NGS methods from 6 European laboratories. Methods included untargeted metagenomics, pre-enrichment by probe-capture followed by Illumina sequencing, and HBV-specific PCR pre-amplification followed by sequencing with Nanopore or Illumina. Results: Full HBV genomes were obtained only from samples with viral loads >1000 IU/ml using probe-capture methods, >200 IU/ml using PCR-Illumina methods, >10 IU/ml using PCR-Nanopore methods, and in no samples using metagenomic methods. Contamination was observed in the negative control and samples with very low viral loads in all PCR-based methods. Probe-capture and metagenomic methods detected additional viruses not routinely screened in blood donations, including polyomaviruses and herpesviruses; positive results were confirmed by PCR. Conclusions: NGS may delineate whole-genome sequences at low viral loads if supported by a PCR pre-amplification step. Probe-capture methods also reliably detect HBV without pre-amplification but achieve limited genome characterisation at low viral loads; they may additionally detect a wide range of blood-borne viruses.
Open AccessNext-Generation Sequencing Methods for Sensitive Hepatitis B Viral Genome Analysis: A European Study
Objectives: This multicentre study investigated the utility of next-generation sequencing (NGS) to detect and generate hepatitis B virus (HBV) genomes in samples of low viral load (from 0.2 to 6207 IU/ml). Methods: 23 HBV DNA positive plasma samples of genotypes A-E and one HBV-negative control sample were assayed blindly via 9 established NGS methods from 6 European laboratories. Methods included untargeted metagenomics, pre-enrichment by probe-capture followed by Illumina sequencing, and HBV-specific PCR pre-amplification followed by sequencing with Nanopore or Illumina. Results: Full HBV genomes were obtained only from samples with viral loads >1000 IU/ml using probe-capture methods, >200 IU/ml using PCR-Illumina methods, >10 IU/ml using PCR-Nanopore methods, and in no samples using metagenomic methods. Contamination was observed in the negative control and samples with very low viral loads in all PCR-based methods. Probe-capture and metagenomic methods detected additional viruses not routinely screened in blood donations, including polyomaviruses and herpesviruses; positive results were confirmed by PCR. Conclusions: NGS may delineate whole-genome sequences at low viral loads if supported by a PCR pre-amplification step. Probe-capture methods also reliably detect HBV without pre-amplification but achieve limited genome characterisation at low viral loads; they may additionally detect a wide range of blood-borne viruses.