Wireless Blood Pressure Monitoring with a Novel Implantable Device: Long-Term In Vivo Results
- 25 January 2014
- journal article
- laboratory investigation
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (6) , 1580-1588
Abstract
Purpose Devices constantly tracking the blood pressure (BP) of hypertensive patients are highly desired to facilitate effective patient management and to reduce hospitalization. We report on experiences gathered in a pilot study that was designed to evaluate the prototype of a newly developed, minimally invasive implantable sensor system for long-term BP monitoring. Methods The device was implanted in the femoral artery (FA) of 12 sheep via standard FA catheterization under fluoroscopic control. Accuracy of the recorded blood pressure was determined by comparison with a reference catheter, which was positioned in the contralateral FA immediately after implantation. Regular follow-up included angiography, computed tomography (CT), and control of functionality and position of the BP sensor. Animals were euthanized after 6 months. FA segments with in situ pressure sensor underwent macroscopic and histopathologic examinations. Results All implantations of the novel sensor device in the FA were successful and uneventful. High-quality BP recordings were documented. Bland–Altman plots indicate very good agreement. Comparison with measurements taken from the reference sensor revealed mean differences and standard deviations of −0.56 ± 0.85, 0.29 ± 1.44, and 0.85 ± 2.27 mmHg (diastolic, systolic, and pulse pressure, respectively) after exclusion of one outlier. CT uncovered deficiencies in cable stability that were addressed in a redesign. No thrombus formation, necrosis, or apoptosis were detected. Conclusions The pilot study proved the technical feasibility of wireless BP measurement in the FA via a novel miniature sensor device.Keywords
This publication has 20 references indexed in Scilit:
- A Novel Fully Implantable Wireless Sensor System for Monitoring Hypertension PatientsIEEE Transactions on Biomedical Engineering, 2012
- Implantable cardiovascular sensors and computers: interventional heart failure strategies.Current Cardiology Reports, 2012
- Effects of Prehypertension and Hypertension Subtype on Cardiovascular Disease in the Asia-Pacific RegionHypertension, 2012
- Optimizing heart failure therapy with implantable sensorsJournal of Arrhythmia, 2012
- Home Monitoring for Heart Failure ManagementJACC, 2012
- Blood Pressure in Early Adulthood, Hypertension in Middle Age, and Future Cardiovascular Disease MortalityJACC, 2011
- Forecasting the Future of Cardiovascular Disease in the United StatesCirculation, 2011
- Role of Home Blood Pressure Monitoring in Overcoming Therapeutic Inertia and Improving Hypertension ControlHypertension, 2011
- A Meta-Analysis of Remote Monitoring of Heart Failure PatientsJACC, 2009
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986