Nina J. Cleven
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nina J. Cleven has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich Steinseifer
A Institute of Applied Medical Engineering , Helmholtz-Institute RWTH Aachen University , Aachen , Germany
2 shared publications - Anna Woitok
Institute for Laboratory Animal Science, RWTH Aachen University, Aachen, Germany
1 shared publication - Benita Hermanns-Sachweh
Institute of Pathology, Medical School of the Technical University of Aachen, Aachen, Germany
1 shared publication - Ingo Nadzeyka
Institute of Applied Medical Engineering, Department of Cardiovascular Engineering Pauwelsstraße 20 52074 Aachen Germany
1 shared publication Max-Philipp Rinno
1 shared publication- Maximilian Kuetting
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen, University, Aachen, Germany
1 shared publication
Latest Publications
- 25 January 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (6) , 1580-1588
Wireless Blood Pressure Monitoring with a Novel Implantable Device: Long-Term In Vivo Results
Purpose Devices constantly tracking the blood pressure (BP) of hypertensive patients are highly desired to facilitate effective patient management and to reduce hospitalization. We report on experiences gathered in a pilot study that was designed to evaluate the prototype of a newly developed, minimally invasive implantable sensor system for long-term BP monitoring. Methods The device was implanted in the femoral artery (FA) of 12 sheep via standard FA catheterization under fluoroscopic control. Accuracy of the recorded blood pressure was determined by comparison with a reference catheter, which was positioned in the contralateral FA immediately after implantation. Regular follow-up included angiography, computed tomography (CT), and control of functionality and position of the BP sensor. Animals were euthanized after 6 months. FA segments with in situ pressure sensor underwent macroscopic and histopathologic examinations. Results All implantations of the novel sensor device in the FA were successful and uneventful. High-quality BP recordings were documented. Bland–Altman plots indicate very good agreement. Comparison with measurements taken from the reference sensor revealed mean differences and standard deviations of −0.56 ± 0.85, 0.29 ± 1.44, and 0.85 ± 2.27 mmHg (diastolic, systolic, and pulse pressure, respectively) after exclusion of one outlier. CT uncovered deficiencies in cable stability that were addressed in a redesign. No thrombus formation, necrosis, or apoptosis were detected. Conclusions The pilot study proved the technical feasibility of wireless BP measurement in the FA via a novel miniature sensor device.
- 25 January 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (6) , 1580-1588
Wireless Blood Pressure Monitoring with a Novel Implantable Device: Long-Term In Vivo Results
Purpose Devices constantly tracking the blood pressure (BP) of hypertensive patients are highly desired to facilitate effective patient management and to reduce hospitalization. We report on experiences gathered in a pilot study that was designed to evaluate the prototype of a newly developed, minimally invasive implantable sensor system for long-term BP monitoring. Methods The device was implanted in the femoral artery (FA) of 12 sheep via standard FA catheterization under fluoroscopic control. Accuracy of the recorded blood pressure was determined by comparison with a reference catheter, which was positioned in the contralateral FA immediately after implantation. Regular follow-up included angiography, computed tomography (CT), and control of functionality and position of the BP sensor. Animals were euthanized after 6 months. FA segments with in situ pressure sensor underwent macroscopic and histopathologic examinations. Results All implantations of the novel sensor device in the FA were successful and uneventful. High-quality BP recordings were documented. Bland–Altman plots indicate very good agreement. Comparison with measurements taken from the reference sensor revealed mean differences and standard deviations of −0.56 ± 0.85, 0.29 ± 1.44, and 0.85 ± 2.27 mmHg (diastolic, systolic, and pulse pressure, respectively) after exclusion of one outlier. CT uncovered deficiencies in cable stability that were addressed in a redesign. No thrombus formation, necrosis, or apoptosis were detected. Conclusions The pilot study proved the technical feasibility of wireless BP measurement in the FA via a novel miniature sensor device.