Experimental investigation on the seismic performance of prefabricated fiber‐reinforced concrete beam‐column joints using grouted sleeve connections
- 20 June 2023
- journal article
- research article
- Published by Wiley in Structural Concrete
- Vol. 24 (4) , 4702-4718
Abstract
To improve the seismic performance of prefabricated reinforced conventional concrete (PRC) beam‐column joints, fiber‐reinforced concrete (FRC) was used instead of concrete in the core zone of the joint in this article. The optimum volume contents of polyvinyl alcohol (PVA) fibers and steel fibers were first determined to be 0.3% and 1%, respectively, through the material properties tests. Then, four PRC beam‐column joint specimens using grouted sleeve connections and one cast‐in‐place reinforced concrete beam‐column joint specimen were designed considering the factors of PVA fibers, steel fibers, with or without stirrups. The test phenomena and failure mode of the five specimens under low‐cycle cyclic loads were obtained. Finally, the effects of PVA fibers, steel fibers, with or without stirrups on the seismic performance of specimens were analyzed and discussed. The test phenomena indicated that the failure mode of specimens was anchorage damage of steel bars. The prefabricated FRC specimens showed relatively little damage in the core zone of the joint. FRC had a significant improvement on the seismic performance of prefabricated beam‐column joints. The use of FRC in the core zone of the joint can reduce or even eliminate the use of stirrups.Keywords
Funding Information
- China Scholarship Council
This publication has 18 references indexed in Scilit:
- Experimental study of a new beam-to-column connection for precast concrete frames under reversal cyclic loadingAdvances in Structural Engineering, 2016
- Structural behavior of RC engineered cementitious composite (ECC) exterior beam–column joints under reversed cyclic loadingConstruction and Building Materials, 2016
- Ductility and Damping Characteristics of PVA-FRC Beam ElementsAdvances in Structural Engineering, 2015
- A new ductile moment-resisting connection for precast concrete frames in seismic regions: An experimental investigationEngineering Structures, 2014
- Application of Engineered Cementitious Composites (ECC) in interior beam–column connections for enhanced seismic resistanceEngineering Structures, 2014
- Effect of polyvinyl alcohol (PVA) fibre on dynamic and material properties of fibre reinforced concreteConstruction and Building Materials, 2013
- Behavior of Concrete and ECC Structures under Simulated Earthquake MotionJournal of Structural Engineering, 2013
- Experimental research and finite element analysis of bridge piers failed in flexure-shear modesEarthquake Engineering and Engineering Vibration, 2008
- Deformation Capacity and Shear Strength of Fiber-Reinforced Cement Composite Flexural Members Subjected to Displacement ReversalsJournal of Structural Engineering, 2007
- Lateral load response of high performance fiber reinforced concrete beam–column jointsConstruction and Building Materials, 2005