Lowering Detection Limits Toward Target Ions Using Quasi-Symmetric Polymeric Ion-Selective Membranes Combined with Amperometric Measurements
Authors:
- 26 September 2016
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (19) , 9850-9855
Abstract
An amperometric method is reported that compensates for the interference from marginally discriminated interfering ions when using traditional polymeric ion-selective membrane (ISM) electrodes. The concept involves utilizing two ISMs in a three-compartment electrochemical cell configuration. The two ISMs are identical in composition except for the addition of an ionophore to one of the membranes. Initially, all three compartments contain the same concentration of interfering ion and the membrane does not contain primary ions. Reference electrodes are placed into each of the two outer compartments. At this point, there is no potential difference between the two reference electrodes. We show experimentally and theoretically that, when the concentration of an interfering species is increased in the sample compartment, the phase-boundary potentials of both sample solution|ISMs change similarly. However, when the primary ion is added to the sample, an asymmetry will emerge, and the membrane with the ionophore will exhibit a larger phase-boundary potential change. At low concentrations, the difference in membrane potentials can be too small for reliable potentiometric detection. Current, which can be routinely measured on pA levels, can be used instead to detect the small primary ion concentration changes with a significant lowering of detection limits. The theory of this method is described by Nernst-Planck-Poisson finite element simulations, and both amperometric and potentiometric experimental verification is demonstrated using ammonium ISM. It is shown that amperometric measurements enable 200 nM ammonium to be detected in the presence of 0.1 mM of potassium, detection capability that is not possible via conventional potentiometry.Keywords
Funding Information
- Magyar Tudományos Akadémia (LP2013-63/2013)
This publication has 29 references indexed in Scilit:
- Abnormally High Ammonium of Natural Origin in a Coastal Aquifer-Aquitard System in the Pearl River Delta, ChinaEnvironmental Science & Technology, 2010
- Limitations of Current Polarization for Lowering the Detection Limit of Potentiometric Polymeric Membrane SensorsAnalytical Chemistry, 2009
- Sensitivity and Working Range of Backside Calibration PotentiometryAnalytical Chemistry, 2007
- Backside Calibration Potentiometry: Ion Activity Measurements with Selective Supported Liquid Membranes by Calibrating from the Inner Side of the MembraneAnalytical Chemistry, 2006
- Novel potentiometric and optical silver ion-selective sensors with subnanomolar detection limitsAnalytica Chimica Acta, 2006
- Potentiometry at Trace Levels in Confined Samples: Ion-Selective Electrodes with Subfemtomole Detection LimitsJournal of the American Chemical Society, 2006
- Picomolar Detection Limits with Current-Polarized Pb2+ Ion-Selective MembranesAnalytical Chemistry, 2001
- Design and Synthesis of a More Highly Selective Ammonium Ionophore Than Nonactin and Its Application as an Ion-Sensing Component for an Ion-Selective ElectrodeAnalytical Chemistry, 2000
- Tailored Transport Through Ion-Selective Membranes for Improved Detection Limits and Selectivity CoefficientsElectroanalysis, 1999
- Large Improvement of the Lower Detection Limit of Ion-Selective Polymer Membrane ElectrodesJournal of the American Chemical Society, 1997