LHLajos Höfler

Lajos Höfler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lajos Höfler has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Detection of Marginally Discriminated Ions with Differential Solid Contact Ion-Selective Electrodes

    by Miklós Márton Kovács, Martin Kis, Lajos Höfler

    A differential sensor is reported for decreasing the interference from multiple ionic and non-ionic species in droplet-sized samples, hence lowering the detection limit for ions that are particularly hard to measure by conventional ion-selective potentiometry. We believe that the proposed approach represents significant progress beyond state-of-the-art by making the application of ion-selective membranes possible for ions that do not have selective ionophores. Two solid contact ion-selective electrodes (SCISEs) are utilized, which are prepared similarly, except for adding ionophore to one of the membranes. We show experimentally and theoretically that a significant signal is observed only when the analyte ion is present in the sample solution. The dynamic response of the sensor is investigated theoretically by Nernst-Planck-Poisson finite element simulations. Symbolic regression is used to generate human-readable expressions. Differential SCISEs are tested under potentiometric and amperometric conditions. While a large potential response is seen in the conventional SCISE vs reference electrode setup at high concentrations of interfering ions, the signal of interfering species is eliminated in the differential SCISE setup. Consequently, it is possible to measure a few μ M levels of ammonium in droplets without the interference of potassium using an ionophore that is not especially selective for ammonium over potassium.


  • Open Access

    Effect of Kinetic and Thermodynamic Properties of Solid Contact Ion-Selective Electrodes on the Electrochemical Impedance Spectroscopy Response

    by Miklós Márton Kovács, Lajos Höfler

    Solid contact ion-selective electrodes (SCISEs) offer many benefits over traditional liquid contact ion-selective electrodes. Their small size made them the default choice in many clinical analysis tools. Reproducibility of their production is crucial in achieving calibration-free sensors. Electrochemical impedance spectroscopy (EIS) is a versatile technique that can provide valuable information on many physico-chemical parameters of examined SCISEs and it can give results under 1 min. Discerning different phenomena that govern the EIS spectrum require the theoretical understanding of the processes (e.g., diffusion, heterogeneous kinetics etc.) that determine the time-dependent response of SCISEs. EIS simulations of SCISEs with Nernst-Planck-Poisson finite element method are applied to describe the experimental response of SCISEs. The numerical simulations are used to train a black-box supervised learning algorithm—a deep feedforward neural network—and a white-box symbolic regression algorithm to learn the underlying model of EIS spectra of SCISEs. The neural networks are used to significantly speed up the solution of the inverse problem of obtaining physico-chemical parameters from experimental data.


  • Open Access

    Application of Potentiometric Ion-Breakthrough to Assess Individual Diffusion Coefficients of Ions in Ion-Selective Membranes

    by Dávid Pocsai, Lajos Höfler

    Ion-selective membranes (ISMs) are at the core of ion-selective electrode development. Fundamentally, two groups of parameters determine the response of ISMs: selectivity coefficients and diffusion coefficients of mobile species in the membrane. It is possible to assess both by performing a single potentiometric ion-breakthrough experiment. Basically, the ISM is placed between two contacting electrolyte solutions that do not contain the ion that the ISM is selective for (primary ion). After primary ion is added the potential trace carries valuable information about the thermodynamics and the kinetics of the membrane. So far, extracting parameters from the experimental results was possible only after unrealistic simplifications (e.g. assuming all of the diffusion are the same). The state-of-the-art simulation technique the Nernst-Planck-Poisson finite element method is utilized to give insight on how the different physico-chemical processes generate the measured potential. Numerical simulations are used to train a feedforward neural network, in order to learn the connection between the physico-chemical parameters (e.g., thickness, diffusion coefficients, selectivity coefficients, coextraction etc.) and the shape of ion-breakthrough potential trace. By using the trained neural network it was possible to quickly obtain for the first time the diffusion coefficient of all of the mobile species in the ISM.


  • Presentation and Verification of an Electrolytic Etching Technique for the Determination of prior Austenite Grain Boundaries in the Steel PH15-5

    by D. Brandl, L. Höfler, M. Stockinger, S. Ploberger, S. Marsoner, G. Ressel

    In the field of hot working, modelling of austenite grain size makes a significant contribution to the prediction of future material properties. One of the difficulties when it comes to modelling is the detection of grain sizes at different recrystallization stages by means of etching methods. Especially with high-purity steels with a martensitic structure, imaging of prior austenite grain boundaries without simultaneous highlighting of lath martensite boundaries, is, in many cases, only possible to some extent when using etching technology. Due to small electrochemical potential differences, increased purity of the alloy causes a more uniform etching attack on grain and lath boundaries and thus leads to a poorer discrimination. An alternative technique for grain size determination is Electron Backscatter Diffraction (EBSD). However, this technique maps only a relatively small area of the sample and is also significantly more expensive than the combination of electrolytic etching and light microscopic analysis. Therefore, this work will present a novel electrolytic etching technique for light microscopic imaging of prior austenite grain boundaries in high-purity and corrosion-resistant grades of precipitation hardening steels. For this purpose, a series of tests was carried out on the alloy PH15-5 and the results were verified by correlative EBSD measurements.


  • Lowering Detection Limits Toward Target Ions Using Quasi-Symmetric Polymeric Ion-Selective Membranes Combined with Amperometric Measurements

    by Xénia Nagy, Lajos Höfler

    An amperometric method is reported that compensates for the interference from marginally discriminated interfering ions when using traditional polymeric ion-selective membrane (ISM) electrodes. The concept involves utilizing two ISMs in a three-compartment electrochemical cell configuration. The two ISMs are identical in composition except for the addition of an ionophore to one of the membranes. Initially, all three compartments contain the same concentration of interfering ion and the membrane does not contain primary ions. Reference electrodes are placed into each of the two outer compartments. At this point, there is no potential difference between the two reference electrodes. We show experimentally and theoretically that, when the concentration of an interfering species is increased in the sample compartment, the phase-boundary potentials of both sample solution|ISMs change similarly. However, when the primary ion is added to the sample, an asymmetry will emerge, and the membrane with the ionophore will exhibit a larger phase-boundary potential change. At low concentrations, the difference in membrane potentials can be too small for reliable potentiometric detection. Current, which can be routinely measured on pA levels, can be used instead to detect the small primary ion concentration changes with a significant lowering of detection limits. The theory of this method is described by Nernst-Planck-Poisson finite element simulations, and both amperometric and potentiometric experimental verification is demonstrated using ammonium ISM. It is shown that amperometric measurements enable 200 nM ammonium to be detected in the presence of 0.1 mM of potassium, detection capability that is not possible via conventional potentiometry.


  • Electrocontrolled Swelling and Water Uptake of a Three‐Dimensional Conducting Polypyrrole Hydrogel

    by Jadielson L. Antonio, Lajos Höfler, Tom Lindfors, Susana I. Córdoba de Torresi

    Polypyrrole 3D hydrosponges of tubular structure were synthesized and electrochemically characterized. The Fourier transform infrared attenuated total reflection (FTIR‐ATR) spectroscopy technique was employed to study the water uptake of the hydrosponges under different conditions. This technique presents several advantages over conventional swelling measurements due to its specificity that allows analyzing the kinetics of water uptake at the molecular level. In combination with mathematical modeling, FTIR‐ATR spectroscopy also enables the calculation of the water diffusion coefficients in the hydrogels. The experimental setup also allows electroswelling of the hydrosponges to be studied. The results presented herein are complementary to those obtained with the electrochemical quartz crystal microbalance with dissipation (EQCM‐D) technique and make it possible to determine the actual role played by water in the ionic exchange occurring in conducting polymers during their redox processes. Whereas EQCM‐D shows the whole mass change in the film provoked by injection/ejection of ions and solvent molecules, FTIR‐ATR spectroscopy follows water flux only, which thus allows separation of the solvent contribution.


  • Syntheses and complexing ability of α-d-gluco- and α-d-xylofuranoside-based lariat ethers

    by Zsolt Rapi, Oliver Ozohanics, Gábor Tóth, Péter Bakó, Lajos Höfler, Tamás Nemcsok, Nándor Kánya, György Keglevich


  • Functional truncated membrane pores

    by David Stoddart, Mariam Ayub, Lajos Höfler, Pinky Raychaudhuri, Jochen W. Klingelhoefer, Giovanni Maglia, Andrew Heron, Hagan Bayley

    Significance: Cells and compartments within them are bounded by membranes, the underlying structure of which is the lipid bilayer. Molecules that move into and out of cells or between compartments are transported through protein channels and pores, which according to conventional thinking completely span the intact bilayer. However, indirect evidence has suggested the existence of a separate class of membrane proteins that perturb the bilayer structure to create transmembrane conduits. We present direct evidence for such proteins, and suggest that they are protagonists in important physiological processes, including defense by the immune system against microorganisms and neuronal damage in Alzheimer's disease.