Impact of different models based on blood samples and images for bone marrow dosimetry after 177Lu-labeled somatostatin-receptor therapy
Open Access
- 2 April 2024
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-13
Abstract
Background: Peptide receptor radionuclide therapy with 177Lu-DOTATATE is a recognized option for treating neuroendocrine tumors and has few toxicities, except for the kidneys and bone marrow. The bone marrow dose is generally derived from a SPECT/CT image-based method with four timepoints or from a blood-based method with up to 9 timepoints, but there is still no reference method. This retrospective single-center study on the same cohort of patients compared the calculated bone marrow dose administered with both methods using mono, bi- or tri-exponential models. For the image-based method, the dose was estimated using Planetdose© software. Pearson correlation coefficients were calculated. We also studied the impact of late timepoints for both methods. Results: The bone marrow dose was calculated for 131 treatments with the blood-based method and for 17 with the image-based method. In the former, the median absorbed dose was 15.3, 20.5 and 28.3 mGy/GBq with the mono-, bi- and tri-exponential model, respectively. With the image-based method, the median absorbed dose was 63.9, 41.9 and 60.8 with the mono-, bi- and tri-exponential model, respectively. Blood samples after 24h post-injection did not evidence any change in the absorbed bone marrow dose with the bi-exponential model. On the contrary, the 6-day post-injection timepoint was more informative with the image-based model. Conclusion: This study confirms that the estimated bone marrow dose is significantly lower with the blood-based method than with the image-based method. The blood-based method with a bi-exponential model proved particularly useful, without the need for blood samples after 24h post-injection. Nevertheless, this blood-based method is based on an assumption that needs to be more validated. The important difference between the two methods does not allow to determine the optimal one to estimate the true absorbed dose and further studies are necessary to compare with biological effects.Keywords
This publication has 38 references indexed in Scilit:
- Assessment of Therapy-Related Myeloid Neoplasms in Patients With Neuroendocrine Tumors After Peptide Receptor Radionuclide TherapyJAMA Oncology, 2020
- Personalized 177Lu-octreotate peptide receptor radionuclide therapy of neuroendocrine tumours: a simulation studyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2017
- Subacute haematotoxicity after PRRT with 177Lu-DOTA-octreotate: prognostic factors, incidence and courseEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- DNA damage in blood lymphocytes in patients after 177Lu peptide receptor radionuclide therapyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- Long-term tolerability of PRRT in 807 patients with neuroendocrine tumours: the value and limitations of clinical factorsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2014
- The evidence base for the use of internal dosimetry in the clinical practice of molecular radiotherapyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2014
- Peptide receptor radionuclide therapy with 177Lu-DOTATATE: the IEO phase I-II studyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Three methods assessing red marrow dosimetry in lymphoma patients treated with radioimmunotherapyCancer, 2010
- Bone marrow dosimetry in peptide receptor radionuclide therapy with [177Lu-DOTA0,Tyr3]octreotateEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- EANM Dosimetry Committee series on standard operational procedures for pre-therapeutic dosimetry I: blood and bone marrow dosimetry in differentiated thyroid cancer therapyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008