    Impact of different models based on blood samples and images for bone marrow dosimetry after 177Lu-labeled somatostatin-receptor therapy

    by Delphine Vallot, Séverine Brillouet, Séléna Pondard, Lavinia Vija, Jean-Sébastien Texier, Lawrence Dierickx, Frédéric Courbon

    Background: Peptide receptor radionuclide therapy with 177Lu-DOTATATE is a recognized option for treating neuroendocrine tumors and has few toxicities, except for the kidneys and bone marrow. The bone marrow dose is generally derived from a SPECT/CT image-based method with four timepoints or from a blood-based method with up to 9 timepoints, but there is still no reference method. This retrospective single-center study on the same cohort of patients compared the calculated bone marrow dose administered with both methods using mono, bi- or tri-exponential models. For the image-based method, the dose was estimated using Planetdose© software. Pearson correlation coefficients were calculated. We also studied the impact of late timepoints for both methods. Results: The bone marrow dose was calculated for 131 treatments with the blood-based method and for 17 with the image-based method. In the former, the median absorbed dose was 15.3, 20.5 and 28.3 mGy/GBq with the mono-, bi- and tri-exponential model, respectively. With the image-based method, the median absorbed dose was 63.9, 41.9 and 60.8 with the mono-, bi- and tri-exponential model, respectively. Blood samples after 24h post-injection did not evidence any change in the absorbed bone marrow dose with the bi-exponential model. On the contrary, the 6-day post-injection timepoint was more informative with the image-based model. Conclusion: This study confirms that the estimated bone marrow dose is significantly lower with the blood-based method than with the image-based method. The blood-based method with a bi-exponential model proved particularly useful, without the need for blood samples after 24h post-injection. Nevertheless, this blood-based method is based on an assumption that needs to be more validated. The important difference between the two methods does not allow to determine the optimal one to estimate the true absorbed dose and further studies are necessary to compare with biological effects.


  • Radiation dose reduction during venous access port implantation: the importance of upgrading equipment and radiation-protection training

    by Delphine Vallot, Ana Cavillon, Amélie Lusque, Philippe Izard, Geneviève Salvignol, Bertrand Delpuech, Régis Fuzier

    Background Implantable central venous port systems are widely used in oncology. We upgraded our fluoroscopy machines, and all anesthetists completed two training courses focusing on the risks of ionizing radiation for patients and health workers. Aims This study aimed to evaluate the impact of upgrading the machines and the radiation-protection training on ionizing radiation exposure during venous port system implantation. Methods We retrospectively analyzed consecutive venous port implantations between 2019 and 2022. The older fluoroscopy machines were replaced by two new machines. A first training session about health worker radioprotection was organized. The medical staff completed a second training course focused on protecting patients from ionizing radiation. We defined four distinct time intervals (TI): venous port implantations performed with the old equipment, the new fluoroscopy machines, after the first training course, and after the second training course. The air kerma-area product (KAP) was compared between these four TI and fluoroscopy times and the number of exposures only with the new machines. Results We analyzed 2587 procedures. A 93% decrease in the median KAP between the first and last TI was noted (median KAP = 323.0 mGy.cm2 vs. 24.0 mGy.cm2, p < 0.0001). A decrease in the KAP was observed for each of the 11 anesthetists. We also noted a significant decrease in the time of fluoroscopy and the number of exposures. Conclusions Upgrading the fluoroscopy equipment and completing two dedicated training courses allowed for a drastic decrease patient exposure to ionizing radiation during venous access port implantation by non-radiologist practitioners.


  • Open Access

    RadioLigand Therapy with [177Lu]Lu-PSMA-617 for Salivary Gland Cancers: Literature Review and First Compassionate Use in France

    by Marie Terroir, Chloé Lamesa, Mehdi Krim, Lavinia Vija, Jean-Sébastien Texier, Thibaut Cassou-Mounat, Jean-Pierre Delord, Delphine Vallot, Frédéric Courbon

    Salivary gland cancers are rare tumors comprising a large group of heterogeneous tumors with variable prognosis. Their therapeutic management at a metastatic stage is challenging due to the lack of therapeutic lines and the toxicity of treatments. [177Lu]Lu-PSMA-617 (prostate-specific membrane antigen) is a vectored radioligand therapy (RLT) initially developed to treat castration-resistant metastatic prostate cancer with encouraging results in terms of efficacy and toxicity. Many malignant cells could be treated with [177Lu]Lu-PSMA-617 as long as they express PSMA as a consequence of androgenic pathway activation. RLT may be used when anti-androgen hormonal treatment has failed, particularly in prostate cancer. [177Lu]Lu-PSMA-617 has been proposed in certain salivary gland cancers, though the expression of PSMA is demonstrated by a significant uptake using [68Ga]Ga-PSMA-11 PET scan. This theranostic approach could be a new therapeutic option, warranting prospective investigation in a larger cohort. We review the literature on this subject and offer a clinical illustration of compassionate use in France as a perspective for administering [177Lu]Lu-PSMA-617 in salivary gland cancer.


  • Open Access

    Setting up a quantitative SPECT imaging network for a European multi-centre dosimetry study of radioiodine treatment for thyroid cancer as part of the MEDIRAD project

    by Jan Taprogge, Francesca Leek, Tino Schurrat, Johannes Tran-Gia, Delphine Vallot, Manuel Bardiès, Uta Eberlein, Michael Lassmann, Susanne Schlögl, Alex Vergara Gil, et al.

    Background: Differentiated thyroid cancer has been treated with radioiodine for almost 80 years, although controversial questions regarding radiation-related risks and the optimisation of treatment regimens remain unresolved. Multi-centre clinical studies are required to ensure recruitment of sufficient patients to achieve the statistical significance required to address these issues. Optimisation and standardisation of data acquisition and processing are necessary to ensure quantitative imaging and patient-specific dosimetry. Material and methods: A European network of centres able to perform standardised quantitative imaging of radioiodine therapy of thyroid cancer patients was set-up within the EU consortium MEDIRAD. This network will support a concurrent series of clinical studies to determine accurately absorbed doses for thyroid cancer patients treated with radioiodine. Five SPECT(/CT) systems at four European centres were characterised with respect to their system volume sensitivity, recovery coefficients and dead time. Results: System volume sensitivities of the Siemens Intevo systems (crystal thickness 3/8″) ranged from 62.1 to 73.5 cps/MBq. For a GE Discovery 670 (crystal thickness 5/8″) a system volume sensitivity of 92.2 cps/MBq was measured. Recovery coefficients measured on three Siemens Intevo systems show good agreement. For volumes larger than 10 ml, the maximum observed difference between recovery coefficients was found to be ± 0.02. Furthermore, dead-time coefficients measured on two Siemens Intevo systems agreed well with previously published dead-time values. Conclusions: Results presented here provide additional support for the proposal to use global calibration parameters for cameras of the same make and model. This could potentially facilitate the extension of the imaging network for further dosimetry-based studies.


  • Open Access

    Evaluation of PET quantitation accuracy among multiple discovery IQ PET/CT systems via NEMA image quality test

    by Delphine Vallot, Elena De Ponti, Sabrina Morzenti, Anna Gramek, Anna Pieczonka, Gabriel Reynés Llompart, Jakub Siennicki, Paul Deak, Chiranjib Dutta, Jorge Uribe, et al.

    Introduction: Quantitative imaging biomarkers are becoming usual in oncology for assessing therapy response. The harmonization of image quantitation reporting has become of utmost importance due to the multi-center trials increase. The NEMA image quality test is often considered for the evaluation of quantitation and is more accurate with a radioactive solid phantom that reduces variability. The goal of this project is to determine the level of variability among imaging centers if acquisition and imaging protocol parameters are left to the center’s preference while all other parameters are fixed including the scanner type. Methods: A NEMA-IQ phantom filled with radioactive 68Ge solid resin was imaged in five clinical sites throughout Europe. Sites reconstructed data with OSEM and BSREM algorithms applying the sites’ clinical parameters. Images were analyzed according with the NEMA-NU2-2012 standard using the manufacturer-provided NEMA tools to calculate contrast recovery (CR) and background variability (BV) for each sphere and the lung error (LE) estimation. In addition, a 18F-filled NEMA-IQ phantom was also evaluated to obtain a gauge for variability among centers when the sites were provided with identical specific instructions for acquisition and reconstruction protocol (the aggregate of data from 12 additional sites is presented). Results: The data using the 68Ge solid phantom showed no statistical differences among different sites, proving a very good reproducibility among the PET center models even if dispersion of data is higher with OSEM compared to BSREM. Furthermore, BSREM shows better CR and comparable BV, while LE is slightly reduced. Two centers exhibit significant differences in CR and BV values for the 18F NEMA NU2-2012 experiments; these outlier results are explained. Conclusion: The same PET system type from the various sites produced similar quantitative results, despite allowing each site to choose their clinical protocols with no restriction on data acquisition and reconstruction parameters. BSREM leads to lower dispersion of quantitative data among different sites. A solid radioactive phantom may be recommended to qualify the sites to perform quantitative imaging.