Mitigation of the line-start effect in PLATO normal camera CCDs for accurate read-out noise characterization
Authors:
- Giacomo CherchiGCGiacomo Cherchi
- Fabrizio CogatoFCFabrizio Cogato
- Nicolas GoriusNGNicolas Gorius
- Alessio AboudanAAAlessio Aboudan
- Jose Lorenzo AlvarezJAJose Lorenzo Alvarez
- Matthias Ammler-Von EiffMEMatthias Ammler-Von Eiff
- Paolo AppollonioPAPaolo Appollonio
- Thierry AppourchauxTAThierry Appourchaux
- Claudio ArenaCAClaudio Arena
- Natalia AuricchioNANatalia Auricchio
- Ann BaekeABAnn Baeke
- Nicolas BeraudNBNicolas Beraud
- 21 August 2026
- conference paper
- Published by SPIE-Intl Soc Optical Eng
- p. 167
Abstract
PLATO (PLAnetary Transits and Oscillations of stars) is the ESA’s M3 mission designed for high-precision photometric monitoring of bright stars, with the aim of detecting and characterising transiting exoplanets and supporting asteroseismic studies of their host stars. Transit detection relies on the noise level affecting the measured stellar light curve. For a star with mV = 11, the PLATO mission-level requirement sets the random Noise-to-Signal Ratio (NSR) below 50 ppm over a one-hour integration. Within this framework, the ReadOut Noise (RON) is one of the quantities used to assess the camera-level performance. During the thermal-vacuum campaigns of the 24 Normal Cameras (N-CAMs), dedicated dump-gate-high bias acquisitions revealed a columndependent electronic offset, referred to as the Line-Start Effect (LSE). When stable, this structure mainly affects the local bias level; when a variable Odd-Even component is present, it can increase the apparent RON estimated from the temporal dispersion of the bias frames. This work presents the characterisation of the LSE in PLATO N-CAMs with the aim of obtaining a more accurate estimate of the RON contribution. The analysis was applied to 23 N-CAMs flight models, excluding N-CAM FM4 because of corrupted data. After correction, the median RON decreases from 45.9 to 44.4 e− RMS. The largest correction is observed for N-CAM FM1, where the RON is reduced by 17.1 e− and the overall NSR decreases from 49.6 to 48 ppm, fully satisfying the 50 ppm requirement.Keywords
This publication has 5 references indexed in Scilit:
- The PLATO missionExperimental Astronomy, 2025
- PLATO’s signal and noise budgetExperimental Astronomy, 2024
- On-ground and in-orbit characterisation plan for the PLATO CCD normal camerasJournal of Instrumentation, 2017
- Optical and dark characterization of the PLATO CCD at ESA2016
- Charge-coupled devices for the ESA PLATO M-class Mission2012