Torque value accuracy of preadjusted metal brackets for upper and lower incisors
- 1 January 2019
- journal article
- research article
- Published by Edizioni Minerva Medica in Minerva Dental and Oral Science
- Vol. 68 (1) , 31-35
Abstract
BACKGROUND: The more accurate the adjustments built into the brackets, the less the need of additional bends in orthodontic archwires during treatment. METHODS: The aim of this study was to investigate the torque value accuracy of Roth prescription brackets from several commercially available brands. A total of 360 upper and lower incisor brackets from six different commercial brands (i.e. 3M Abzil, KiriumLine; Dentsply GAC, Ovation; Morelli, Roth Light; Ormco, Synthesis; Rocky Mountain Orthodontics, Integra; and 3M Unitek, Miniature Twin) were selected and divided into 18 experimental groups (N.=20). RESULTS: The brackets were submitted to SEM examination to acquire clear photomicrographs of all edges. The angles formed by the slot's walls and bracket's base were measured to calculate the torque values. The measured torque values were submitted to Student's t-test or Mann-Whitney test (global alpha=0.05) for comparing the experimental groups to Roth prescription values, depending on the bracket indication: +12 degrees, +8 degrees or -1 degrees. A tolerance of +/- 1 degrees (ISO 27020:2010) was considered. Only experimental groups using upper central incisor brackets from Rocky Mountain Orthodontics (P=0.037) and 3M Unitek (P=0.001) were statistically different compared to the Roth prescription ones (+12 degrees). However, all the groups presented great variability (standard deviation) regarding the same brand and indication, showing that there is no accuracy in the fabrication process. CONCLUSIONS: It is evident that the manufacturing methods of orthodontic brackets need to reach higher degrees of precision and homogeneity.Keywords
This publication has 15 references indexed in Scilit:
- Orthodontic bracket slot dimensions as measured from entire bracket seriesThe Angle Orthodontist, 2015
- Evolution of treatment mechanics and contemporary appliance design in orthodontics: A 40-year perspectiveAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2015
- Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurationsThe Angle Orthodontist, 2014
- Comparative analysis of slot dimension in lingual bracket systemsHead & Face Medicine, 2009
- Force Decay of Elastomeric Ligatures: Influence onUnloading Force Compared to Self-LigationThe Angle Orthodontist, 2009
- Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic bracketsEuropean Journal of Orthodontics, 2008
- Torque expression of self-ligating bracketsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- Materials-induced variation in the torque expression of preadjusted appliancesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- Three-dimensional relationship between the critical contact angle and the torque angleAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- Preadjusted edgewise appliances: Theory and practiceAmerican Journal of Orthodontics, 1978