Nasal continuous positive airway pressure from high flow cannula versus Infant Flow for preterm infants
Authors:
Open Access
- 13 July 2006
- journal article
- research article
- Published by Springer Nature in Journal of Perinatology
- Vol. 26 (9) , 546-549
Abstract
To compare the feasibility of continuous positive airway pressure (CPAP) support generated by high flow nasal cannula with conventional CPAP for prevention of reintubation among preterm infants with a birth weight of 1250 g. Preterm infants were randomized to CPAP generated via high flow cannula or the Infant Flow Nasal CPAP System (VIASYS, Conshohocken, PA, USA) at extubation. Primary outcome was incidence of reintubation within 7 days. Secondary outcomes included change in oxygen use and frequency of apnea and bradycardias postextubation. Forty neonates were randomized. Twelve of 20 infants randomized to high flow cannula CPAP were reintubated compared to three of 20 using Infant Flow (P=0.003). The high flow cannula group had increased oxygen use and more apneas and bradycardias postextubation. CPAP delivered by high flow nasal cannula failed to maintain extubation status among preterm infants 1250 g as effectively as Infant Flow CPAP.Keywords
This publication has 16 references indexed in Scilit:
- Work of Breathing During Nasal Continuous Positive Airway Pressure in Preterm Infants: A Comparison of Bubble vs Variable-Flow DevicesJournal of Perinatology, 2005
- Use of Oxygen Cannulas in Extremely Low Birthweight Infants is Associated with Mucosal Trauma and Bleeding, and Possibly with Coagulase-negative Staphylococcal SepsisJournal of Perinatology, 2003
- A randomised control study comparing the Infant Flow Driver with nasal continuous positive airway pressure in preterm infantsArchives of Disease in Childhood - Fetal and Neonatal Edition, 2001
- High-Flow Nasal Cannulae in the Management of Apnea of Prematurity: A Comparison With Conventional Nasal Continuous Positive Airway PressurePediatrics, 2001
- Nasal deformities resulting from flow driver continuous positive airway pressure.Archives of Disease in Childhood - Fetal and Neonatal Edition, 1996
- Neonatal nasal deformities secondary to nasal continuous positive airway pressureThe Laryngoscope, 1994
- Role of positive end‐expiratory pressure changes on functional residual capacity in surfactant treated preterm infantsPediatric Pulmonology, 1994
- Nasal continuous positive airway pressure: experiences with a new technical approachActa Paediatrica, 1993
- Effect of nasal CPAP on thoracoabdominal motion in neonates with respiratory insufficiencyPediatric Pulmonology, 1991
- A new device for administration of nasal continuous positive airway pressure in the newbornCritical Care Medicine, 1988