DCDouglas M Campbell

Douglas M Campbell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Douglas M Campbell has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Michael Sgro

    Department of Paediatrics, St Michael’s Hospital

    2 shared publications
  • Brenda Stade

    Department of Paediatrics, St Michael’s Hospital

    1 shared publication
  • E N Kelly

    Department of Paediatrics, Mt Sinai Hospital, University of Toronto, Toronto, ON, Canada

    1 shared publication
  • Karoon C Danayan

    Department of Paediatrics, University of Toronto

    1 shared publication
  • Michael Farrugia

    Department of Paediatrics, St Michael's Hospital, University of Toronto, Toronto, Ontario

    1 shared publication
  • P S Shah

    Department of Paediatrics, Mt Sinai Hospital, University of Toronto, Toronto, ON, Canada

    1 shared publication

Latest Publications

  • Open Access

    Transcutaneous bilirubin measurement at the time of hospital discharge in a multiethnic newborn population

    by Douglas M Campbell, Karoon C Danayan, Valleverdina McGovern, Sohail Cheema, Brenda Stade, Michael Sgro

    Severe neonatal hyperbilirubinemia continues to occur in healthy newborns. Recent guidelines have supported using transcutaneous devices in estimating bilirubin levels. Previous studies using these devices are limited. Newborns requiring serum bilirubin level measurements before hospital discharge were recruited prospectively. The agreement between a transcutaneous bilirubin (TCB) and total serum bilirubin (TSB) level was assessed. Sensitivity analysis was conducted. A total of 430 infants were enrolled. Correlation between the values was high (Pearson's correlation coefficient 0.83; Lin's concordance coefficient 0.81 [95% CI 0.77 to 0.84]; P<0.001). The mean (± SD) TSB level was 194±60 µmol/L. The TCB measurement tended to overestimate the value (mean difference 12.7), with wide 95% limits of agreement (–52 µmol/L to 77 µmol/L). Sensitivity and specificity analysis of TCB values allowed estimation of clinically important TSB levels. The TCB correlated, but was imprecise in predicting TSB. TCB values can be used at the time of discharge to safely plan care for jaundiced infants if the limits of agreement are considered and clinical judgment is maintained.


  • Open Access

    High-fidelity simulation in neonatal resuscitation

    by Douglas M Campbell, Tony Barozzino, Michael Farrugia, Michael Sgro

    There are currently few studies describing the use of high-fidelity (hi-fi) simulation in teaching neonatal resuscitation. Traditionally, residents are certified in the neonatal resuscitation program (NRP) after successful completion of a multiple-choice written examination and demonstration of skills during a hands-on ‘mega-code’. In the present study, the use of a hi-fi simulation mannequin was compared with a standard plastic mannequin when teaching the megacode portion of the NRP. In the present pilot study, 15 first-year residents were randomly assigned to demonstrate neonatal resuscitation knowledge, with either the hi-fi mannequin (SimBaby, Laerdal Medical Corporation, USA) or a traditional plastic mannequin (ALS Baby, Laerdal Medical Corporation, USA). A written evaluation was conducted before and after the intervention. Each pair of residents experienced the two scenarios. Video performance was then assessed and compared. Residents randomly assigned to the hi-fi mannequin rated the experience higher (31±3.3 versus 27±3.5; P=0.026), and required less redirection from instructors during the megacode (scenario 1: 4.5±1.7 versus 15±6.9; P=0.015 and scenario 2: 1.8±1.3 versus 9.3±2.5; P=0.0009) than those who were randomly assigned to the plastic mannequin. Residents randomly assigned to the hi-fi mannequin did not have improved written scores or improved intubation times. The present pilot study demonstrated that a hi-fi mannequin can be used as part of an educational program, such as the NRP. The use of this technology in neonatal resuscitation training is well-received by learners and may provide a more realistic model for training. Further work is required to clarify its role in task performance and team training.


  • Open Access

    Nasal continuous positive airway pressure from high flow cannula versus Infant Flow for preterm infants

    by D M Campbell, P S Shah, V Shah, E N Kelly

    To compare the feasibility of continuous positive airway pressure (CPAP) support generated by high flow nasal cannula with conventional CPAP for prevention of reintubation among preterm infants with a birth weight of 1250 g. Preterm infants were randomized to CPAP generated via high flow cannula or the Infant Flow Nasal CPAP System (VIASYS, Conshohocken, PA, USA) at extubation. Primary outcome was incidence of reintubation within 7 days. Secondary outcomes included change in oxygen use and frequency of apnea and bradycardias postextubation. Forty neonates were randomized. Twelve of 20 infants randomized to high flow cannula CPAP were reintubated compared to three of 20 using Infant Flow (P=0.003). The high flow cannula group had increased oxygen use and more apneas and bradycardias postextubation. CPAP delivered by high flow nasal cannula failed to maintain extubation status among preterm infants 1250 g as effectively as Infant Flow CPAP.