Characterization of airway mucus using quantitative MRI: an in vitro proof-of-concept study
Authors:
Open Access
- 26 October 2026
- journal article
- research article
- Published by Springer Nature in European Radiology Experimental
- Vol. 10 (1) , 163
Abstract
Objectives: A characteristic of chronic obstructive pulmonary disease is mucus hypersecretion. In this proof-of-concept study, we aimed to characterize airway mucus using a quantitative ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequence in a controlled in vitro synthetic mucus model to establish a technical foundation for future in vivo studies. Materials and methods: UTE double-echo steady-state (UTE-DESS) was performed to acquire the signal from free induction decay-like signal and spin/stimulated echo-like signal echoes; quantitative MRI parameters (T1, T2, and diffusivity) were estimated. Synthetic mucus phantoms were prepared using mucin (0.20%, 0.50%, and 1.0%) mixed with xanthan gum (0.10%, 0.25%, and 0.50%) to replicate the viscoelastic properties of human laryngeal mucus, and samples were embedded in 1% agar for imaging. Results: The mucus phantoms with varying concentrations of mucin and xanthan exhibited visual differences in color and opacity. Estimated T1 values were 2.23 ± 0.16, 2.37 ± 0.20, and 2.09 ± 0.18 s (mean ± standard deviation) for the three tubes with relative mucus concentrations of 1, 2.5, and 5, respectively. Corresponding T2 values were 806.6 ± 105.6, 687.4 ± 78.0, and 475.0 ± 41.3 ms, while diffusivity values were 2.36 ± 0.14, 2.31 ± 0.18, and 2.33 ± 0.18 µm 2 /ms for the three tubes. Only the T2 relaxation times showed a significant linear correlation with mucus concentration ( r = -0.9998, p = 0.0112). Conclusion: UTE-DESS MRI could be feasible for characterizing airway mucus. T2 relaxation time showed a strong inverse correlation with increasing mucus concentration, indicating its sensitivity to mucus content. Key Points: Question Can a novel quantitative ultrashort echo time MRI sequence noninvasively characterize airway mucus properties and overcome conventional lung imaging limitations in muco-obstructive diseases? Findings In this controlled in vitro model, UTE-DESS MRI mapping demonstrated that T2 relaxation times alone showed a strong inverse correlation with increasing mucus concentrations. Relevance statement This exploratory proof-of-concept establishes a technical foundation for radiation-free, noninvasive T2 mapping to monitor and phenotype chronic obstructive pulmonary disease and other mucoobstructive lung diseases in future in vivo studies.Keywords
Funding Information
- NIH
- DFG
This publication has 42 references indexed in Scilit:
- Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative studyMagnetic Resonance in Medicine, 2025
- Global Burden of Chronic Obstructive Pulmonary Disease Through 2050JAMA Network Open, 2023
- Longitudinal Evaluation of Bronchial Changes in Cystic Fibrosis Patients Undergoing Elexacaftor/Tezacaftor/Ivacaftor Therapy Using Lung MRI With Ultrashort Echo‐TimesJournal of Magnetic Resonance Imaging, 2023
- Airway-Occluding Mucus Plugs and Mortality in Patients With Chronic Obstructive Pulmonary DiseaseJAMA, 2023
- Ultrashort echo time Cones double echo steady state (UTE‐Cones‐DESS) for rapid morphological imaging of short T2 tissuesMagnetic Resonance in Medicine, 2021
- Proton MRI of the Lung: How to Tame Scarce Protons and Fast Signal DecayJournal of Magnetic Resonance Imaging, 2020
- UTE‐SENCEFUL: first results for 3D high‐resolution lung ventilation imagingMagnetic Resonance in Medicine, 2018
- Imaging and T2 relaxometry of short‐T2 connective tissues in the knee using ultrashort echo‐time double‐echo steady‐state (UTEDESS)Magnetic Resonance in Medicine, 2017
- Synthetic tracheal mucus with native rheological and surface tension propertiesJournal of Biomedical Materials Research Part A, 2013
- Ultra‐short echo time (UTE) MR imaging of the lung: Comparison between normal and emphysematous lungs in mutant miceJournal of Magnetic Resonance Imaging, 2010