Water as a Blood Model for Determination of CO2 Removal Performance of Membrane Oxygenators
Authors:
- Benjamin LukitschBLBenjamin Lukitsch
- Raffael KollerRKRaffael Koller
- Paul EckerPEPaul Ecker
- Martin ElenkovMEMartin Elenkov
- Christoph JaneczekCJChristoph Janeczek
- Markus PekovitsMPMarkus Pekovits
- Bahram HaddadiBHBahram Haddadi
- Christian JordanCJChristian Jordan
- Margit GfoehlerMGMargit Gfoehler
- Michael HarasekMichael Harasek
Open Access
Abstract
CO2 removal via membrane oxygenators has become an important and reliable clinical technique. Nevertheless, oxygenators must be further optimized to increase CO2 removal performance and to reduce severe side effects. Here, in vitro tests with water can significantly reduce costs and effort during development. However, they must be able to reasonably represent the CO2 removal performance observed with blood. In this study, the deviation between the CO2 removal rate determined in vivo with porcine blood from that determined in vitro with water is quantified. The magnitude of this deviation (approx. 10%) is consistent with results reported in the literature. To better understand the remaining difference in CO2 removal rate and in order to assess the application limits of in vitro water tests, CFD simulations were conducted. They allow to quantify and investigate the influences of the differing fluid properties of blood and water on the CO2 removal rate. The CFD results indicate that the main CO2 transport resistance, the diffusional boundary layer, behaves generally differently in blood and water. Hence, studies of the CO2 boundary layer should be preferably conducted with blood. In contrast, water tests can be considered suitable for reliable determination of the total CO2 removal performance of oxygenators.Keywords
Funding Information
- Österreichische Forschungsförderungsgesellschaft (857859)
This publication has 26 references indexed in Scilit:
- Compilation of Henry's law constants (version 4.0) for water as solventAtmospheric Chemistry and Physics, 2015
- Effect of Impeller Design and Spacing on Gas Exchange in a Percutaneous Respiratory Assist CatheterArtificial Organs, 2014
- Evaluation of a Respiratory Assist Catheter that Uses an Impeller Within a Hollow Fiber Membrane BundleASAIO Journal, 2009
- A Mathematical Model to Predict CO2 Removal in Hollow Fiber Membrane OxygenatorsAnnals of Biomedical Engineering, 2008
- Mass and momentum transfer in blood oxygenatorsChemical Engineering Science, 2002
- Transient adhesion of platelets in pump-oxygenator systems: influence of SMA and nitric oxide treatmentsJournal of Biomaterials Science, Polymer Edition, 1999
- Sweep Gas Flowrate and C02 Exchange in Artificial LungsArtificial Organs, 1996
- Quantitative description of whole blood CO2 dissociation curve and Haldane effectRespiration Physiology, 1983
- Towards the ultimate conservative difference scheme. II. Monotonicity and conservation combined in a second-order schemeJournal of Computational Physics, 1974
- Diffusion of Dissolved Gases in LiquidsChemical Reviews, 1964