Tetanic stimulation of the peripheral nerve augments motor evoked potentials by re-exciting spinal anterior horn cells
- 9 January 2021
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 36 (1) , 259-270
Abstract
Tetanic stimulation of the peripheral nerve, immediately prior to conducting transcranial electrical stimulation motor evoked potential (TES-MEP), increases MEP amplitudes in both innervated and uninnervated muscles by the stimulated peripheral nerve; this is known as the remote augmentation of MEPs. Nevertheless, the mechanisms underlying the remote augmentation of MEPs remain unclear. Although one hypothesis was that remote augmentation of MEPs results from increased motoneuronal excitability at the spinal cord level, the effect of spinal anterior horn cells has not yet been investigated. We aimed to investigate the effect of tetanic stimulation of the peripheral nerve on spinal cord anterior horn cells by analyzing the F-wave. We included 34 patients who underwent elective spinal surgeries and compared the changes in F-waves and TES-MEPs pre- and post-tetanic stimulation of the median nerve. F-wave analyses were recorded by stimulating the median and tibial nerves. TES-MEPs and F-wave analyses were compared between baseline and post-tetanic stimulation time periods using Wilcoxon signed-rank tests. A significant augmentation of MEPs, independent of the level corresponding to the median nerve, was demonstrated. Furthermore, F-wave persistence was significantly increased not only in the median nerve but also in the tibial nerve after tetanic stimulation of the median nerve. The increased F-wave persistence indicates an increase of re-excited motor units in spinal anterior horn cells. These results confirm the hypothesis that tetanic stimulation of the peripheral nerve may cause remote augmentation of MEPs, primarily by increasing the excitability of the anterior horn cells.Keywords
This publication has 46 references indexed in Scilit:
- Evaluation of Posttetanic Motor Evoked Potentials—The Influences of Repetitive Use, the Residual Effects of Tetanic Stimulation to Peripheral Nerve, and the VariabilityJournal of Neurosurgical Anesthesiology, 2010
- Evaluation of Reliability of Post-Tetanic Motor-Evoked Potential Monitoring During Spinal Surgery Under General AnesthesiaSpine, 2008
- The Application of Tetanic Stimulation of the Unilateral Tibial Nerve Before Transcranial Stimulation Can Augment the Amplitudes of Myogenic Motor-Evoked Potentials from the Muscles in the Bilateral Upper and Lower LimbsAnesthesia & Analgesia, 2008
- The Effects of the Neuromuscular Blockade Levels on Amplitudes of Posttetanic Motor-Evoked Potentials and Movement in Response to Transcranial Stimulation in Patients Receiving Propofol and Fentanyl AnesthesiaAnesthesia & Analgesia, 2008
- Spinal Cord Monitoring in Patients With Spinal Deformity and Neural Axis AbnormalitiesSpine, 2006
- Intraoperative spinal cord monitoring of motor function with myogenic motor evoked potentials: a consideration in anesthesiaJournal of Anesthesia, 2004
- Propofol and Sevoflurane in Subanesthetic Concentrations Act Preferentially on the Spinal CordAnesthesiology, 2002
- Antagonism of the Antinocifensive Action of Halothane by Intrathecal Administration of GABA-A Receptor AntagonistsAnesthesiology, 1996
- Variability of Motor-Evoked Potentials Recorded During Nitrous Oxide Anesthesia from the Tibialis Anterior Muscle After Transcranial Electrical StimulationAnesthesia & Analgesia, 1996
- Cortical modulation of spinal excitability: an F-wave studyElectroencephalography and Clinical Neurophysiology/Electromyography and Motor Control, 1996