Abstract
Rationale and Objectives. The aim of this study is to determine the effect of needle size on the diagnostic yield and complication rate of lung nodule biopsy. Materials and Methods. A total of 209 patients are included in a retrospective study. All patients underwent a needle lung biopsy under computer-tomography-guided guidance. Multiple different needle gauges are used in this study. Results. We found no correlation between the gauge of the needle and the incidence of complications or diagnostic yield associated with lung nodule biopsy. However, there was a statistically significant difference in the number of needle passes and the gauge of the needle (

This publication has 15 references indexed in Scilit: