WMWilliam Moore

William Moore

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William Moore has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Priya Bhattacharji

    Department of Radiology, State University of New York at Stony Brook, University Hospital, HSC Level IV, Room 060, Stony Brook, NY 11794

    2 shared publications
  • Vadim Grechushkin

    Department of Radiology, State University of New York at Stony Brook, University Hospital, HSC Level IV, Room 060, Stony Brook, NY 11794

    2 shared publications
  • Ammar Chaudhry

    Department of Radiology, State University of New York at Stony Brook, University Hospital, HSC Level IV, Room 060, Stony Brook, NY 11794

    1 shared publication
  • April Plank

    Stony Brook Univ Hosp, Dept Radiol, Stony Brook, NY USA

    1 shared publication
  • Ayman Sawas

    Department of Radiology, Stony Brook University Hospital, State University of New York, HSC Level IV, Room 120 Stony Brook, NY 11794, USA

    1 shared publication
  • Bari Dane

    New York University, New York, USA

    1 shared publication

Latest Publications

  • Cryoneurolysis in Patients with Refractory Chronic Peripheral Neuropathic Pain

    by Jung Hwoon Edward Yoon, Vadim Grechushkin, Ammar Chaudhry, Priya Bhattacharji, Brian Durkin, William Moore


    • 1 January 2013
      • Vol. 3  (5) , 408-416

    PET/CT vs. non-contrast CT alone for surveillance 1-year post lobectomy for stage I non-small-cell lung cancer

    by Bari Dane, Vadim Grechushkin, April Plank, William Moore, Thomas Bilfinger

    F-18-FDG PET/CT was compared with non-contrast chest CT in monitoring for recurrence 1-year after lobectomy of stage 1 non-small-cell lung cancer (NSCLC). For surveillance after treatment with curative intent, current (April 2012) National Comprehensive Cancer network guidelines recommend chest CT with or without contrast every 6-12 months for 2 years, then non-contrast chest CT annually. PET/CT is not currently indicated for routine follow-up. One hundred patients receiving surveillance PET/CT 1-year after lobectomy for the treatment of stage 1a or 1b NSCLC were included in the study. Exclusion criteria included the presence or interval diagnosis of a second malignancy, or surgical treatment more radical than single lobectomy. The non-contrast CT obtained from the 1-year PET/CT was interpreted by an experienced chest radiologist blinded to the PET/CT for evidence of recurrence using the following findings: pulmonary nodule, pleural effusion, pleural mass, adenopathy, and extrathoracic mass. The decision about recurrence was made solely from the non-contrast CT without PET/CT findings. This was compared with the determination made with PET/CT. The reference standard for determination of recurrence was the multidisciplinary tumor board who had access to all imaging and clinical data. Recurrence at 1 year was documented in 16 of 90 patients. All 16 recurrences were documented with PET/CT and 9 were found with non-contrast CT. Five of the 7 recurrences missed with non-contrast CT were extrathoracic metastases. Sensitivity of CT and PET/CT for recurrence was 56.3% and 100%, respectively (p = 0.015). Specificity of CT and PET/CT for recurrence was 95.9% and 93.2%, respectively (p = 0.62).


  • Open Access

    Needle Gauge and Cytological Yield in CT-Guided Lung Biopsy

    by William Moore, Ayman Sawas, Cindy Lee, John Ferretti

    Rationale and Objectives. The aim of this study is to determine the effect of needle size on the diagnostic yield and complication rate of lung nodule biopsy. Materials and Methods. A total of 209 patients are included in a retrospective study. All patients underwent a needle lung biopsy under computer-tomography-guided guidance. Multiple different needle gauges are used in this study. Results. We found no correlation between the gauge of the needle and the incidence of complications or diagnostic yield associated with lung nodule biopsy. However, there was a statistically significant difference in the number of needle passes and the gauge of the needle (


  • Open Access

    Sensitivity and Specificity of a CAD Solution for Lung Nodule Detection on Chest Radiograph with CTA Correlation

    by William Moore, Jennifer Ripton-Snyder, George Wu, Craig Hendler

    The objective of this research was to determine the sensitivity and specificity of a commercially available computer-aided detection (CAD) system for detection of lung nodule on posterior–anterior (PA) chest radiograph in a varied patient population who are referred to computed tomographic angiogram (CTA) of the chest as a reference standard. Patients who had a PA chest radiograph with concomitant CTA of the chest were included in this retrospective study. The PA chest radiograph was analyzed by a CAD device, and results were recorded. A qualitative assessment of the CAD results was performed using a 5-point Likert scale. The CTA was then reviewed to determine if there were correlative nodules. The presence of a correlative nodule between 0.5 cm and 1.5 cm was considered a positive result. The baseline sensitivity of the system was determined to be 0.707 (95% CI = 0.52–0.86), with a specificity of 0.50 (95% CI = 0.38–0.76). Positive predictive value was 0.30 (95% CI = 0.24–0.49), with a negative predictive value of 0.858 (95% CI = 0.82–0.95), and accuracy of 0.555 (95% CI = 0.40–0.66). When excluding nodules that were qualitatively determined by a thoracic radiologist to be false positives, the specificity was 0.781 (95% CI = 0.764–0.839), the positive predictive value was 0.564 (95% CI = 0.491–0.654), the negative predictive value was 0.829 (95% CI = 0.819–0.878), and the accuracy was 0.737 (95% CI = 0.721–0.801). The use of CAD for lung nodule detection on chest radiograph, when used in conjunction with an experienced radiologist, has a very good sensitivity, specificity, and accuracy.


  • Multidetector Computed Tomography Pulmonary Angiogram in the Assessment of Myocardial Infarction

    by William Moore, Jack Fields, Brian Mieczkowski

    The objective of this study is to evaluate the effectiveness of nonelectrocardiographic gated multidetector computed tomography (MDCT) performed for the purpose of assessment of pulmonary embolus in the evaluation of myocardial infarction (MI). We retrospectively evaluated 147 consecutive patients who had a computed tomography angiogram for pulmonary embolus on a 16-detector MDCT. Of this cohort, we determined 11 patients to have acute MIs based on electrocardiogram, positive troponin levels, and clinical findings and history. Four additional patients were found to have chronic MI based on history. The MDCT data were evaluated by an attending Radiologist, blinded to the clinical data, for quantitative and qualitative attenuations. Each MI was assigned a region of the heart based on its anatomical sections. We were able to detect 10 of 15 MIs, resulting in an overall sensitivity and specificity of 66.6% and 91.4%, respectively. The overall accuracy was 76.7%. If non-Q wave MIs are excluded from the data set, the sensitivity increased to 76.9%. Quantitative analysis of each region of the heart showed that there was a statistically significant difference (P < 0.01) between the infracting regions of the heart (69 +/- 3.3 SEM) and those with normal perfusion (93.3 +/- 1.0 SEM). While this method did prove to be effective at determining patients who had an MI, the low sensitivity and inability to differentiate chronic from acute myocardial infarction suggest that this technique is very limited in clinical practice.


  • Pulmonary Infiltration from Chronic Lymphocytic Leukemia

    by William Moore, Daniel Baram, Youjun Hu

    We present 2 patients with chronic lymphocytic leukemia infiltration of the lung resulting in centrilobular nodularity on computed tomography. We present the x-ray and computed tomography patterns with pathological findings in these cases.