Visual Field Stability After Trifocal Intraocular Lens Implantation: A Longitudinal Standard Automated Perimetry Study
Authors:
- Wilson Takashi HidaWHWilson Takashi Hida
- Bernardo Kaplan MoscoviciBMBernardo Kaplan Moscovici
- Michael ChowMCMichael Chow
- Patrick Frensel de Moraes TzelikisPTPatrick Frensel de Moraes Tzelikis
- Mario Augusto Pereira Dias ChavesMCMario Augusto Pereira Dias Chaves
- Pedro Carlos CarricondoPCPedro Carlos Carricondo
Open Access
- 1 March 2026
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-8
Abstract
Purpose: To investigate whether implantation of a diffractive trifocal intraocular lens (IOL) is followed by systematic changes in standard automated perimetry (SAP) global indices and test reliability in a paired pre–post design. Methods: Patients who underwent uncomplicated cataract surgery with PanOptix trifocal IOL implantation and completed SAP before and after surgery under the same institutional protocol were analyzed. Baseline SAP was obtained within 6 months preoperatively, and follow-up SAP was obtained within 12 months postoperatively. Unreliable examinations were excluded, and right and left eyes were analyzed separately. Outcomes included mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), foveal threshold, and reliability indices. Pre- and postoperative values were compared using paired tests. Results: Reliability remained comparable to baseline. False-positive rates were 1.7% ± 2.6% preoperatively versus 1.6% ± 1.6% postoperatively in right eyes (p = 0.88) and 1.5% ± 2.1% versus 1.3% ± 1.9% in left eyes (p = 0.73). False-negative rates were 0.9% ± 1.5% versus 1.7% ± 2.1% in right eyes (p = 0.24) and 1.5% ± 2.2% versus 1.9% ± 2.5% in left eyes (p = 0.62). Global indices showed no significant pre–post differences: MD was − 1.3 ± 1.2 dB versus − 1.2 ± 0.9 dB in right eyes (p = 0.54) and − 1.7 ± 1.6 dB versus − 1.5 ± 1.6 dB in left eyes (p = 0.65). VFI was 99.0% ± 0.4% versus 98.9% ± 0.9% in right eyes (p = 0.77) and 98.2% ± 0.8% versus 97.8% ± 1.8% in left eyes (p = 0.45). PSD was unchanged (right p = 0.34; left p = 0.08). Foveal threshold decreased slightly in right eyes (35.9 ± 1.3 to 35.0 ± 1.1 dB, p = 0.06). Conclusion: Trifocal IOL implantation was not associated with clinically meaningful deterioration in SAP global indices or reliability measures during follow-up.Keywords
This publication has 31 references indexed in Scilit:
- Patient-Reported Outcomes of Visual Disturbances with a Trifocal Intraocular Lens: A Meta-AnalysisOphthalmology and Therapy, 2024
- Longitudinal evaluation of trifocal and extended depth of focus lenses implantation using standard automated perimetry parametersInternational Ophthalmology, 2023
- Trifocal intraocular lenses versus bifocal intraocular lenses after cataract extraction among participants with presbyopiaCochrane Database of Systematic Reviews, 2023
- Patients satisfaction and clinical outcomes of binocular implantation of a new trifocal intraocular lensInternational Ophthalmology, 2020
- Results of a clinical evaluation of a trifocal intraocular lens in JapanJapanese Journal of Ophthalmology, 2020
- Comparative analysis of visual outcomes, reading skills, contrast sensitivity, and patient satisfaction with two models of trifocal diffractive intraocular lenses and an extended range of vision intraocular lensGraefe's Archive for Clinical and Experimental Ophthalmology, 2018
- Reduction in Mean Deviation Values in Automated Perimetry in Eyes With Multifocal Compared to Monofocal Intraocular Lens ImplantsAmerican Journal of Ophthalmology, 2014
- Influence of Multifocal Intraocular Lenses on Standard Automated Perimetry Test ResultsJAMA Ophthalmology, 2013
- Effect of Cataract Extraction on the Results of Automated Perimetry in GlaucomaArchives of Ophthalmology (1950), 1997
- Test-Retest Variability in Glaucomatous Visual FieldsAmerican Journal of Ophthalmology, 1989