Short‐Term Effects of Different Transcatheter Edge‐to‐Edge Devices on Mitral Valve Geometry
Open Access
- 5 September 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (17) , e030333
Abstract
Background: Short‐term effects on mitral valve (MV) anatomy after transcatheter edge‐to‐edge repair using the PASCAL system remain unknown. Precise quantification might allow for an advanced analysis of predictors for mean transmitral gradients. Methods and Results: Consecutive patients undergoing transcatheter edge‐to‐edge repair for secondary mitral regurgitation using PASCAL or MitraClip systems were included. Quantification of short‐term MV changes throughout the cardiac cycle was performed using peri‐interventional 3‐dimensional MV images. Predictors for mean transmitral gradients were identified in univariable and multivariable regression analysis. Long‐term results were described during 1‐year follow‐up. A total of 100 patients undergoing transcatheter edge‐to‐edge repair using PASCAL (n=50) or MitraClip systems (n=50) were included. Significant reductions of anterior‐posterior diameter, annular circumference, and area throughout the cardiac cycle were found in both cohorts ( P 2 ; P =0.049) and late diastole (2.7±1.1 versus 2.2±0.8 cm 2 ; P =0.036) compared with the MitraClip cohort. Besides a device‐specific profile of independent predictor of mean transmitral gradients, reduction of middiastolic anatomic MV orifice area was identified as an independent predictor in both the PASCAL ( β =−0.410; P =0.001) and MitraClip cohorts ( β =−0.318; P =0.028). At follow‐up, reduction of mitral regurgitation grade to mild or less was more durable in the PASCAL cohort (90% versus 72%; P =0.035). Conclusions: PASCAL and MitraClip showed comparable short‐term effects on MV geometry. However, PASCAL might better preserve MV function and demonstrated more durable mitral regurgitation reduction during follow‐up. Identification of independent predictors for mean transmitral gradients might potentially help to guide device selection in the future.Keywords
This publication has 20 references indexed in Scilit:
- Transcatheter Valve Repair for Patients With Mitral RegurgitationJACC: Cardiovascular Interventions, 2019
- Transcatheter Mitral-Valve Repair in Patients with Heart FailureThe New England journal of medicine, 2018
- Changes in dynamic mitral valve geometry during percutaneous edge–edge mitral valve repair with the MitraClip systemJournal of Echocardiography, 2018
- Acute Effect of Mitral Valve Repair on Mitral Valve GeometryThe Thoracic and Cardiovascular Surgeon, 2018
- Left ventricular remodelling patterns after MitraClip implantation in patients with severe mitral valve regurgitation: mechanistic insights and prognostic implicationsEuropean Heart Journal - Cardiovascular Imaging, 2018
- Compassionate use of the PASCAL transcatheter mitral valve repair system for patients with severe mitral regurgitation: a multicentre, prospective, observational, first-in-man studyThe Lancet, 2017
- Elevated Mitral Valve Pressure Gradient After MitraClip Implantation Deteriorates Long-Term Outcome in Patients With Severe Mitral Regurgitation and Severe Heart FailureJACC: Cardiovascular Interventions, 2017
- Clinical Trial Design Principles and Endpoint Definitions for Transcatheter Mitral Valve Repair and Replacement: Part 2: Endpoint DefinitionsJACC, 2015
- Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular ImagingEuropean Heart Journal - Cardiovascular Imaging, 2015
- Percutaneous Mitral Repair With the MitraClip SystemJACC, 2009