Massimiliano Meineri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Massimiliano Meineri has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Joerg Ender
Heart Center Leipzig at University of Leipzig
4 shared publications Azad Mashari
Department of Anesthesia and Pain Management, Peter Munk Cardiac Center Toronto General Hospital, University Health Network, Toronto, Canada
3 shared publicationsJoerg Ender
Department of Anesthesia and Intensive Medicine, Herzzentrum Leipzig, Leipzig, Germany
3 shared publicationsAnna Flo Forner
Department of Anesthesia and Intensive Medicine, Herzzentrum Leipzig, Leipzig, Germany
2 shared publicationsGiulia Maria Ruggeri
Department of Anesthesia and Pain Management, Peter Munk Cardiac Center Toronto General Hospital, University Health Network, Toronto, Canada
2 shared publications- Holger Thiele
Department of Cardiology, Heart Center Leipzig at Leipzig University , Leipzig
2 shared publications
Latest Publications
- Open Access
- 15 November 2025
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 40 (3) , 788-795
Intraprocedural 3- and 2-Dimensional Transesophageal Echocardiographic Evaluation of Tricuspid Valve Annular Geometry After Edge-to-Edge Repair Using 2 Clips
- 15 November 2025
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 40 (3) , 788-795
Open AccessIntraprocedural 3- and 2-Dimensional Transesophageal Echocardiographic Evaluation of Tricuspid Valve Annular Geometry After Edge-to-Edge Repair Using 2 Clips
- Open Access
- 16 July 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (14) , e033964
Incidence and Outcomes of Emergency Intraprocedural Surgical Conversion During Transcatheter Aortic Valve Implantation: A Multicentric Analysis
- 16 July 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (14) , e033964
Open AccessIncidence and Outcomes of Emergency Intraprocedural Surgical Conversion During Transcatheter Aortic Valve Implantation: A Multicentric Analysis
- 9 March 2024
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 38 (7) , 1467-1476
Intraoperative and Intraprocedural Use of 3-Dimensional Transesophageal Echocardiography: An International European Association of Cardiothoracic Anesthesia and Intensive Care Survey of Cardiac Surgical Centers
- 9 March 2024
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 38 (7) , 1467-1476
Intraoperative and Intraprocedural Use of 3-Dimensional Transesophageal Echocardiography: An International European Association of Cardiothoracic Anesthesia and Intensive Care Survey of Cardiac Surgical Centers
- Open Access
- 5 September 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (17) , e030333
Short‐Term Effects of Different Transcatheter Edge‐to‐Edge Devices on Mitral Valve Geometry
Background: Short‐term effects on mitral valve (MV) anatomy after transcatheter edge‐to‐edge repair using the PASCAL system remain unknown. Precise quantification might allow for an advanced analysis of predictors for mean transmitral gradients. Methods and Results: Consecutive patients undergoing transcatheter edge‐to‐edge repair for secondary mitral regurgitation using PASCAL or MitraClip systems were included. Quantification of short‐term MV changes throughout the cardiac cycle was performed using peri‐interventional 3‐dimensional MV images. Predictors for mean transmitral gradients were identified in univariable and multivariable regression analysis. Long‐term results were described during 1‐year follow‐up. A total of 100 patients undergoing transcatheter edge‐to‐edge repair using PASCAL (n=50) or MitraClip systems (n=50) were included. Significant reductions of anterior‐posterior diameter, annular circumference, and area throughout the cardiac cycle were found in both cohorts ( P 2 ; P =0.049) and late diastole (2.7±1.1 versus 2.2±0.8 cm 2 ; P =0.036) compared with the MitraClip cohort. Besides a device‐specific profile of independent predictor of mean transmitral gradients, reduction of middiastolic anatomic MV orifice area was identified as an independent predictor in both the PASCAL ( β =−0.410; P =0.001) and MitraClip cohorts ( β =−0.318; P =0.028). At follow‐up, reduction of mitral regurgitation grade to mild or less was more durable in the PASCAL cohort (90% versus 72%; P =0.035). Conclusions: PASCAL and MitraClip showed comparable short‐term effects on MV geometry. However, PASCAL might better preserve MV function and demonstrated more durable mitral regurgitation reduction during follow‐up. Identification of independent predictors for mean transmitral gradients might potentially help to guide device selection in the future.
- 5 September 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (17) , e030333
Open AccessShort‐Term Effects of Different Transcatheter Edge‐to‐Edge Devices on Mitral Valve Geometry
Background: Short‐term effects on mitral valve (MV) anatomy after transcatheter edge‐to‐edge repair using the PASCAL system remain unknown. Precise quantification might allow for an advanced analysis of predictors for mean transmitral gradients. Methods and Results: Consecutive patients undergoing transcatheter edge‐to‐edge repair for secondary mitral regurgitation using PASCAL or MitraClip systems were included. Quantification of short‐term MV changes throughout the cardiac cycle was performed using peri‐interventional 3‐dimensional MV images. Predictors for mean transmitral gradients were identified in univariable and multivariable regression analysis. Long‐term results were described during 1‐year follow‐up. A total of 100 patients undergoing transcatheter edge‐to‐edge repair using PASCAL (n=50) or MitraClip systems (n=50) were included. Significant reductions of anterior‐posterior diameter, annular circumference, and area throughout the cardiac cycle were found in both cohorts ( P 2 ; P =0.049) and late diastole (2.7±1.1 versus 2.2±0.8 cm 2 ; P =0.036) compared with the MitraClip cohort. Besides a device‐specific profile of independent predictor of mean transmitral gradients, reduction of middiastolic anatomic MV orifice area was identified as an independent predictor in both the PASCAL ( β =−0.410; P =0.001) and MitraClip cohorts ( β =−0.318; P =0.028). At follow‐up, reduction of mitral regurgitation grade to mild or less was more durable in the PASCAL cohort (90% versus 72%; P =0.035). Conclusions: PASCAL and MitraClip showed comparable short‐term effects on MV geometry. However, PASCAL might better preserve MV function and demonstrated more durable mitral regurgitation reduction during follow‐up. Identification of independent predictors for mean transmitral gradients might potentially help to guide device selection in the future.
- Open Access
- 10 October 2022
- Published by Medknow in Annals of Cardiac Anaesthesia
- Vol. 25 (4) , 479-484
Impact of a One-Day Three-Dimensional Transesophageal Echocardiography Workshop on Clinical Practice at a Single Academic Centre
Background: Transesophageal echocardiography (TEE) is a powerful diagnostic tool which has become an integral part in the management of cardiac surgery patients. We developed a one-day 3D TEE workshop specifically designed to meet the needs of perioperative cardiac anaesthesiologists. We hypothesized that participation in the workshop would increase the uptake of 3D TEE in routine perioperative practice. Aims: To examine the impact of one-day 3D TEE workshop on 3D TEE image acquisition and incorporation into routine perioperative practice. Setting: Tertiary care hospital. Design: Prospective observational monocentric study. Subjects and Methods: A convenience sample of 20 cardiac anesthesiologists (with an option to attend the one- day workshop midway through the study) from a single center consented to have their intraoperative TEE images collected during the course of the study reviewed for research purposes. Images acquired 6 months before, immediately after, and 6 months following the workshop and images were examined by a blinded, expert echocardiographer. Results: Data collected for 16 participants (8 workshop attendees, 8 non-attendees) indicate that the TEE workshop increased the number of 3D TEE images, but not x images acquired immediately following the workshop (P=0.006). No difference was observed in number of 3D images at six months' post workshop. Workshop participants obtained more 3D and multi-plane images after the workshop and more 3D images at 6 months compared to those who did not attend the workshop. Conclusion: Our study suggests that a single day hands-on 3D TEE workshop may have had an impact on the implementation of intraoperative 3D TEE in experienced echocardiographers.
- 10 October 2022
- Published by Medknow in Annals of Cardiac Anaesthesia
- Vol. 25 (4) , 479-484
Open AccessImpact of a One-Day Three-Dimensional Transesophageal Echocardiography Workshop on Clinical Practice at a Single Academic Centre
Background: Transesophageal echocardiography (TEE) is a powerful diagnostic tool which has become an integral part in the management of cardiac surgery patients. We developed a one-day 3D TEE workshop specifically designed to meet the needs of perioperative cardiac anaesthesiologists. We hypothesized that participation in the workshop would increase the uptake of 3D TEE in routine perioperative practice. Aims: To examine the impact of one-day 3D TEE workshop on 3D TEE image acquisition and incorporation into routine perioperative practice. Setting: Tertiary care hospital. Design: Prospective observational monocentric study. Subjects and Methods: A convenience sample of 20 cardiac anesthesiologists (with an option to attend the one- day workshop midway through the study) from a single center consented to have their intraoperative TEE images collected during the course of the study reviewed for research purposes. Images acquired 6 months before, immediately after, and 6 months following the workshop and images were examined by a blinded, expert echocardiographer. Results: Data collected for 16 participants (8 workshop attendees, 8 non-attendees) indicate that the TEE workshop increased the number of 3D TEE images, but not x images acquired immediately following the workshop (P=0.006). No difference was observed in number of 3D images at six months' post workshop. Workshop participants obtained more 3D and multi-plane images after the workshop and more 3D images at 6 months compared to those who did not attend the workshop. Conclusion: Our study suggests that a single day hands-on 3D TEE workshop may have had an impact on the implementation of intraoperative 3D TEE in experienced echocardiographers.
- Open Access
- 2 December 2021
- Published by Springer Nature in Journal of Anesthesia, Analgesia and Critical Care
- Vol. 1 (1) , 1-9
Echocardiographic assessment of left ventricular function in ex situ heart perfusion using pump-supported and passive afterload working mode: a pilot study
Ex situ heart perfusion (ESHP) has been developed to decrease cold ischemia time and allow metabolic assessment of donor hearts prior to transplantation. Current clinical ESHP systems preserve the heart in an unloaded condition and only evaluate the cardiac metabolic profile. In this pilot study we performed echocardiographic functional assessment using two alternative systems for left ventricular (LV) loading: pump supported afterload working mode (SAM) and passive afterload working modes (PAM). Six hearts were procured from male Yorkshire pigs. During cold ischemia, hearts were mounted on our custom made ESHP circuit and a 3D-printed enclosure for the performance of echocardiography with a standard TEE probe. Following perfusion with Langherdorf mode of the unloaded heart, the system was switched into different working modes to allow LV loading and functional assessment: pump supported (SAM) and passive (PAM). Echocardiographic assessment of left ventricular function in the donor hearts was performed in vivo and at 1 h of ESHP with SAM, after 4.5 h with PAM and after 5.5 h with SAM. We obtained good quality epicardial echocardiographic images at all time points allowing a comprehensive LV systolic assessment. All indices showed a decrease in LV systolic function throughout the trial with the biggest drop after heart harvesting. We demonstrated the feasibility of echocardiographic functional assessment during ESHP and two different working modes. The expected LV systolic dysfunction consisted of a reduction in EF, FAC, FS, and strain throughout the experiment with the most significant decrease after harvesting.
- 2 December 2021
- Published by Springer Nature in Journal of Anesthesia, Analgesia and Critical Care
- Vol. 1 (1) , 1-9
Open AccessEchocardiographic assessment of left ventricular function in ex situ heart perfusion using pump-supported and passive afterload working mode: a pilot study
Ex situ heart perfusion (ESHP) has been developed to decrease cold ischemia time and allow metabolic assessment of donor hearts prior to transplantation. Current clinical ESHP systems preserve the heart in an unloaded condition and only evaluate the cardiac metabolic profile. In this pilot study we performed echocardiographic functional assessment using two alternative systems for left ventricular (LV) loading: pump supported afterload working mode (SAM) and passive afterload working modes (PAM). Six hearts were procured from male Yorkshire pigs. During cold ischemia, hearts were mounted on our custom made ESHP circuit and a 3D-printed enclosure for the performance of echocardiography with a standard TEE probe. Following perfusion with Langherdorf mode of the unloaded heart, the system was switched into different working modes to allow LV loading and functional assessment: pump supported (SAM) and passive (PAM). Echocardiographic assessment of left ventricular function in the donor hearts was performed in vivo and at 1 h of ESHP with SAM, after 4.5 h with PAM and after 5.5 h with SAM. We obtained good quality epicardial echocardiographic images at all time points allowing a comprehensive LV systolic assessment. All indices showed a decrease in LV systolic function throughout the trial with the biggest drop after heart harvesting. We demonstrated the feasibility of echocardiographic functional assessment during ESHP and two different working modes. The expected LV systolic dysfunction consisted of a reduction in EF, FAC, FS, and strain throughout the experiment with the most significant decrease after harvesting.
- 1 June 2021
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 35 (6) , 1654-1662
Association Between Three-Dimensional Left Ventricular Outflow Tract Area and Gradients After Myectomy in Hypertrophic Obstructive Cardiomyopathy
- 1 June 2021
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 35 (6) , 1654-1662
Association Between Three-Dimensional Left Ventricular Outflow Tract Area and Gradients After Myectomy in Hypertrophic Obstructive Cardiomyopathy
- 1 January 2021
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 35 (1) , 208-215
Evaluation of a Patient-Specific, Low-Cost, 3-Dimensional–Printed Transesophageal Echocardiography Human Heart Phantom
- 1 January 2021
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 35 (1) , 208-215
Evaluation of a Patient-Specific, Low-Cost, 3-Dimensional–Printed Transesophageal Echocardiography Human Heart Phantom
- 24 August 2020
- Published by Wolters Kluwer Health in A&A Practice
- Vol. 14 (10) , e01288
Intraoperative Diagnosis of Subaortic Stenosis in a Young Patient Scheduled for Elective Aortic Valve Replacement
A 25-year-old patient with a history of aortic stenosis due to presumed bicuspid aortic valve presented for elective aortic valve replacement. Intraoperative transesophageal echocardiography (TEE) revealed a trileaflet aortic valve but detected the presence of a subvalvular membrane. Multiplanar reconstruction of the 3-dimensional (3D) dataset measured a cross-sectional area of 0.8 cm2 at the level of this subvalvular membrane. Successful resection resulted in relief of the obstruction. Compared with preoperative transthoracic echocardiography, TEE was able to correctly characterize the nature of the stenosis with area determination accurately provided by application of 3D techniques.
- 24 August 2020
- Published by Wolters Kluwer Health in A&A Practice
- Vol. 14 (10) , e01288
Intraoperative Diagnosis of Subaortic Stenosis in a Young Patient Scheduled for Elective Aortic Valve Replacement
A 25-year-old patient with a history of aortic stenosis due to presumed bicuspid aortic valve presented for elective aortic valve replacement. Intraoperative transesophageal echocardiography (TEE) revealed a trileaflet aortic valve but detected the presence of a subvalvular membrane. Multiplanar reconstruction of the 3-dimensional (3D) dataset measured a cross-sectional area of 0.8 cm2 at the level of this subvalvular membrane. Successful resection resulted in relief of the obstruction. Compared with preoperative transthoracic echocardiography, TEE was able to correctly characterize the nature of the stenosis with area determination accurately provided by application of 3D techniques.
- 1 June 2020
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 34 (2) , 141-152
Preoperative management of anticoagulation in the surgical patient: Highlights of the latest guidelines
- 1 June 2020
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 34 (2) , 141-152
Preoperative management of anticoagulation in the surgical patient: Highlights of the latest guidelines