Numerical Washout Study of a Pulsatile Total Artificial Heart
- 1 March 2014
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 37 (3) , 241-252
Abstract
Purpose: For blood pumps with long term indication, blood stagnation can result in excessive thromboembolic risks for patients. This study numerically investigates the washout performance of the left pump chamber of a pulsatile total artificial heart (TAH) as well as the sensitivity of the rotational orientation of the inlet bileaflet mechanical heart valve (MHV) on blood stagnation. Methods: To quantitatively evaluate the washout efficiency, a fluid-structure interaction (FSI) simulation of the artificial heart pumping process was combined with a blood washout model. Four geometries with different orientations (0°, 45°, 90° and 135°) of the inlet valve were compared with respect to washout performance. Results: The calculated flow field showed a high level of agreement with particle image velocimetry (PIV) measurements. Almost complete washout was achievable after three ejection phases. Remains of old blood in relation to the chamber volume was below 0.6% for all configurations and were mainly detected opposite to the inlet and outlet port at the square edge where the membrane and the pump chamber are connected. Only a small variation in the washout efficiency and the general flow field was observed. An orientation of 0° showed minor advantages with respect to blood stagnation and recirculation. Conclusions: Bileaflet MHVs were demonstrated to be only slightly sensitive to rotation regarding the washout performance of the TAH. The proposed numerical washout model proved to be an adequate tool to quantitatively compare different configurations and designs of the artificial organ regarding the potential for blood stagnation where experimental measurements are limited.Keywords
This publication has 37 references indexed in Scilit:
- Simulation of a pulsatile total artificial heart: Development of a partitioned Fluid Structure Interaction modelJournal of Fluids and Structures, 2013
- A Quantitative Comparison of Mechanical Blood Damage Parameters in Rotary Ventricular Assist Devices: Shear Stress, Exposure Time and Hemolysis IndexJournal of Biomechanical Engineering, 2012
- Validation of an Axial Flow Blood Pump: Computational Fluid Dynamics Results Using Particle Image VelocimetryArtificial Organs, 2011
- Flow Analysis of Ventricular Assist Device Inflow and Outflow Cannula Positioning Using a Naturally Shaped Ventricle and Aortic BranchArtificial Organs, 2010
- Computational Fluid Dynamics Analysis of Blade Tip Clearances on Hemodynamic Performance and Blood Damage in a Centrifugal Ventricular Assist DeviceArtificial Organs, 2010
- Towards Non-thrombogenic Performance of Blood Recirculating DevicesAnnals of Biomedical Engineering, 2010
- Validation of a CFD Methodology for Positive Displacement LVAD Analysis Using PIV DataJournal of Biomechanical Engineering, 2009
- Numerical Dye Washout Method as a Tool for Characterizing the Heart Valve Flow: Study of Three Standard Mechanical Heart ValvesASAIO Journal, 2008
- The 50cc Penn State Left Ventricular Assist Device: A Parametric Study of Valve Orientation Flow DynamicsASAIO Journal, 2006
- Two-equation eddy-viscosity turbulence models for engineering applicationsAIAA Journal, 1994