Investigating potential physicochemical errors in polymer gel dosimeters
Authors:
- Rachel BujoldRBRachel Bujold
- Martin LepageMLMartin Lepage
- 26 August 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (18) , 6083-6107
Abstract
Measurement errors in polymer gel dosimetry can originate either during irradiation or scanning. One concern related to the exothermic nature of polymerization reaction was that the heat released in polymer gel dosimeters during irradiation modifies their dose response. In this paper, the effect of heat released from the exothermal polymerization reaction on the dose response of a number of dosimeters was studied. In addition, we investigated whether heat-generated geometric distortion existed in newly proposed gel dosimeters that contain highly thermoresponsive polymers. Our results suggest that despite a significant internal temperature increase in some gel compositions, their dose responses are not affected when oxygen is well expelled mechanically from the gel mixture. We also report on significant pre-irradiation instability in some recently developed polymer gel dosimeters but that geometric distortions were not observed. Data obtained by a set of small calibration vials are compared to those obtained from larger phantoms, and potential physicochemical causes of deviations between them are identified.Keywords
This publication has 64 references indexed in Scilit:
- Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose responsePhysics in Medicine & Biology, 2011
- Liquid ionization chamber calibrated gel dosimetry in conformal stereotactic radiotherapy of brain lesionsActa Oncologica, 2008
- Basic investigations on the performance of a normoxic polymer gel with tetrakis‐hydroxy‐methyl‐phosphonium chloride as an oxygen scavenger: Reproducibility, accuracy, stability, and dose rate dependenceMedical Physics, 2006
- A self consistent normalized calibration protocol for three dimensional magnetic resonance gel dosimetryMagnetic Resonance Imaging, 2002
- The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapyPhysics in Medicine & Biology, 2000
- New Polyimides for Gas Separation. 1. Polyimides Derived from Substituted Terphenylenes and 4,4‘-(Hexafluoroisopropylidene)diphthalic AnhydrideMacromolecules, 1999
- Reaction behaviour and kinetic constants for photopolymerizations of multi(meth)acrylate monomersPolymer, 1994
- Estimation of polymerization efficiency in the formation of polyacrylamide gel, using continuous optical scanning during polymerizationJournal of Biochemical and Biophysical Methods, 1979
- Radiation induced polymerizationRadiation Physics and Chemistry (1977), 1979
- Analytical and Preparative Polyacrylamide Gel Electrophoresis1976