Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response
Authors:
- A JirasekAJA Jirasek
- L J SchreinerLSL J Schreiner
- K B McAuleyKMK B McAuley
- 8 March 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (7) , 2091-2102
Abstract
This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range (~0.88 H Gy(-1)) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent (~0.80 H Gy(-1)). This new gel formulation results in enhanced dose resolution (~0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.Keywords
This publication has 47 references indexed in Scilit:
- Polymer gel dosimetryPhysics in Medicine & Biology, 2010
- How does the chemistry of polymer gel dosimeters affect their performance?Journal of Physics: Conference Series, 2009
- Effects of glycerol co-solvent on the rate and form of polymer gel dose responsePhysics in Medicine & Biology, 2009
- Adaptive mean filtering for noise reduction in CT polymer gel dosimetryMedical Physics, 2007
- X-ray computed tomography imaging of polymer gel dosimetersJournal of Physics: Conference Series, 2006
- The dose response of normoxic polymer gel dosimeters measured using X-ray CTBritish Journal of Radiology, 2005
- Fundamentals of MRI measurements for gel dosimetryJournal of Physics: Conference Series, 2004
- An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomographyPhysics in Medicine & Biology, 2001
- Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gelPhysics in Medicine & Biology, 1996
- Polymer-Cosolvent Systems. IV. Upper and Lower Critical Solution Temperatures in the System Methylcyclohexane-Diethyl Ether-PolystyreneMacromolecules, 1974