New regression formula for toric intraocular lens calculations
Authors:
- 1 May 2016
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (5) , 663-671
Abstract
To evaluate and compare the accuracy of 2 toric intraocular lens (IOL) calculators with or without a new regression formula. Ein-Tal Eye Center, Tel-Aviv, Israel, and the Lions Eye Institute, Nedlands, Western Australia, Australia. Retrospective case series. A new regression formula (Abulafia-Koch) was developed to calculate the estimated total corneal astigmatism based on standard keratometry measurements. The error in the predicted residual astigmatism was calculated by the Alcon and Holladay toric IOL calculators with and without adjustments by the Abulafia-Koch formula. These results were compared with those of the Barrett toric calculator. Data from 78 eyes were evaluated to validate the Abulafia-Koch formula. The centroid errors in predicted residual astigmatism were against-the-rule with the Alcon (0.55 diopter [D]) and Holladay (0.54 D) toric calculators and decreased to 0.05 D (P < .001 [x-axis], P = .776 [y-axis]) and 0.04 D (P < .001 [x-axis], P = .726 [y-axis]) with adjustments by the Abulafia-Koch formula. The Alcon and the Holladay toric calculators had a higher proportion of eyes within ±0.50 D of the predicted residual astigmatism with the Abulafia-Koch formula (76.9% and 78.2%, respectively) than without it (both 30.8%). There were no significant differences between the results of the Abulafia-Koch-modified Alcon and the Holladay toric calculators and those of the Barrett toric calculator. Adjustment of commercial toric IOL calculators by the Abulafia-Koch formula significantly improved the prediction of postoperative astigmatic outcome. Dr. Abulafia received a speaker's fee from Haag-Streit AG. Dr. Barrett has licensed the Barrett Toric Calculator to Haag-Streit AG. Dr. Koch is a consultant to Alcon Laboratories, Inc., Abbott Medical Optics, Inc., and Revision Optics, Inc. Dr. Hill is a paid consultant to Haag-Streit AG and Alcon Laboratories, Inc. None of the other authors has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 26 references indexed in Scilit:
- A Ray Tracing Approach to Calculate Toric Intraocular LensesJournal of Refractive Surgery, 2013
- A New Slant on Toric Intraocular Lens Power CalculationJournal of Refractive Surgery, 2013
- Contribution of posterior corneal astigmatism to total corneal astigmatismJournal of Cataract & Refractive Surgery, 2012
- Univariate and bivariate polar value analysis of corneal astigmatism measurements obtained with 6 instrumentsJournal of Cataract & Refractive Surgery, 2012
- Simulation of toric intraocular lens results: Manual keratometry versus dual-zone automated keratometry from an integrated biometerJournal of Cataract & Refractive Surgery, 2011
- Impact of axis misalignment of toric intraocular lenses on refractive outcomes after cataract surgeryJournal of Cataract & Refractive Surgery, 2010
- The AcrySof Toric Intraocular Lens in Subjects with Cataracts and Corneal AstigmatismOphthalmology, 2010
- Correlation between keratometric and refractive astigmatism in pseudophakic eyesJournal of Cataract & Refractive Surgery, 2010
- Foldable toric intraocular lens for astigmatism correction in cataract patientsJournal of Cataract & Refractive Surgery, 2008
- Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lensesJournal of Cataract & Refractive Surgery, 2007