Free-breathing, zero-TE MR lung imaging
- 9 September 2014
- journal article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 28 (3) , 207-215
Abstract
The investigation of three-dimensional radial, zero-echo time (TE) imaging for high-resolution, free-breathing magnetic resonance (MR) lung imaging using prospective and retrospective motion correction. Zero-TE was implemented similarly to the rotating-ultra-fast-imaging-sequence, providing 3D, isotropic, radial imaging with proton density contrast. Respiratory motion was addressed using prospective triggering (PT), prospective gating (PG) and retrospective gating (RG) with physiological signals obtained from a respiratory belt and interleaved pencil beam and DC navigators. The methods were demonstrated on four healthy volunteers at 3T. 3D, radial zero-TE imaging with high imaging bandwidth and nominally zero echo-time enables efficient capture of short-lived signals from the lung parenchyma and the vessels. Compared to Cartesian encoding, unaccounted for free-breathing respiration resulted in only benign blurring artifacts confined to the origin of motion. Breath holding froze respiration but achieved only limited image resolution (~1.8 mm, 30 s). PT and PG obtained similar quality expiratory-phase images at 1.2 mm resolution in ~6 min scan time. RG allowed multi-phase imaging in ~15 min, derived from eight individually stored averages. Zero-TE appears to be an attractive pulse sequence for 3D isotropic lung imaging. Prospective and retrospective approaches provide high-quality, free-breathing MR lung imaging within reasonable scan time.Keywords
This publication has 34 references indexed in Scilit:
- Ultra-fast steady state free precession and its application to in vivo 1 H morphological and functional lung imaging at 1.5 teslaMagnetic Resonance in Medicine, 2013
- Lung Morphology Assessment with Balanced Steady-State Free Precession MR Imaging Compared with CTRadiology, 2012
- Parallel imaging with nonlinear reconstruction using variational penaltiesMagnetic Resonance in Medicine, 2011
- MRI with zero echo time: Hard versus sweep pulse excitationMagnetic Resonance in Medicine, 2011
- MRI of the lung – state of the artDiagnostic and Interventional Radiology, 2011
- Compression Belt for Navigator-triggered trueFISP Whole-heart Coronary Magnetic Resonance Angiography: Study in Healthy VolunteersMagnetic Resonance in Medical Sciences, 2008
- k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlationsMagnetic Resonance in Medicine, 2003
- On the performance and accuracy of 2D navigator pulsesMagnetic Resonance Imaging, 1999
- T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imagingEuropean Journal of Radiology, 1999
- Lung parenchyma: projection reconstruction MR imaging.Radiology, 1991