Experimentally designed sensor for the real-time detection of Molnupiravir degradation: Optimization, Characterization, and Application"
Preprint
- 25 October 2024
- preprint
- Published by Springer Nature in Research Square
Abstract
Isobutyric acid is short-chain fatty acid. In pharmaceutical analysis, quantifying isobutyric acid is essential for ensuring the purity and stability of pharmaceutical products. Molnupiravir, for instance, is an antiviral drug approved by the FDA to treat COVID-19. Isobutyric acid is a known impurity that may be present in Molnupiravir formulations due to the synthesis process or degradation over time. Isobutyric acid can irritate the lungs. Repeated exposure may cause bronchitis to develop with cough, phlegm, and/or shortness of breath. The current study is the first study for isobutyric acid determination used carbon paste electrodes. Tetradodecyl ammonium chloride surfactant (TDAC) used as ionophore in a quality-by-design approach to develop and optimize a carbon-paste sensor for isobutyric acid . Twenty-one sensors with different compositions were tested, and the results were computationally analyzed to generate prediction models. Using the prediction models, the function predicted with 96.7% desirability that a sensor containing 16.85% ion-exchanger, 0% graphene, and o-NPOE as a plasticizer would achieve a Nernstian slope of 57.035 mV/decade, an R-squared approaching unity, and a response time of 6.2 seconds. The sensor accurately measured isobutyric acid concentrations within a wide linear range (9.0×10-8 –1.0×10-2 mol L-1) with high sensitivity and selectivity. The sensor’s morphologya and compostion were examined using the scanning electron microscope and energy-dispersive X-ray analysis. Isobutyric acid was determined in different smamples like waste water, urine and plasma and spiked Molnupiravir standard samples. Molnupiravir thermal stability also was examined using proposed electrode. The results obtained from electrochemical method was compared with data obtained from HPLC method.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- A novel potentiometric approach for the sensitive detection of cadmium in real samples using modified carbon paste electrodesElectroanalysis, 2023
- HPLC-DAD method for the quantitative determination of short-chain fatty acids in meconium samplesMicrochemical Journal, 2020
- Validation and application of an ultrahigh-performance liquid chromatographic-Orbitrap mass spectrometric method for the simultaneous detection and quantification of volatile and non-volatile organic acids in human faecal samplesJournal of Pharmaceutical and Biomedical Analysis, 2017
- Simultaneous determination of six short-chain fatty acids in colonic contents of colitis mice after oral administration of polysaccharides from Chrysanthemum morifolium Ramat by gas chromatography with flame ionization detectorJournal of Chromatography B, 2016
- Carbon Paste Electrodes in Facts, Numbers, and Notes: A Review on the Occasion of the 50‐Years Jubilee of Carbon Paste in Electrochemistry and ElectroanalysisElectroanalysis, 2008
- Potentiometric Ion-Selective Electrodes2007
- Simple and rapid method for determination of short-chain fatty acids in biological materials by high-performance liquid chromatography with ultraviolet detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1992
- Determination of ethanol, volatile fatty acids, lactic and succinic acids in fermentation liquids by gas chromatographyJournal of the Science of Food and Agriculture, 1985
- Volatile fatty acids in human peripheral and portal blood: Quantitative determination by vacuum distillation and gas chromatographyClinica Chimica Acta, 1981
- Spectroscopic determination of the energy of complexes of isobutyric acid with piperidineJournal of Applied Spectroscopy, 1972