Safa S. El-Sanafery
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Safa S. El-Sanafery has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Gehad Genidy Mohamed
Chemistry Department, Faculty of Science, Cairo University, Giza, Egypt
2 shared publications - Ahmed Sadeq Abou-Elyazed
Chemistry Department, Faculty of Science, Menoufia University, Shebin El-Kom, 32512, Egypt
1 shared publication Ahmed Sayed Saad
Cairo University
1 shared publicationAshraf A. Abbas
Department of Chemistry, Faculty of Science, Cairo University, Giza, 12613, Egypt
1 shared publication- Ashraf A. Abbas
Department of Chemistry, Faculty of Science, Cairo University, Giza, 12613, Egypt
1 shared publication Gehad G. Mohamed
Department of Chemistry, Faculty of Science, Cairo University, Giza, 12613, Egypt
1 shared publication
Latest Publications
- Open Access
- 25 October 2024
- Published by Springer Nature in Research Square
Experimentally designed sensor for the real-time detection of Molnupiravir degradation: Optimization, Characterization, and Application"
Isobutyric acid is short-chain fatty acid. In pharmaceutical analysis, quantifying isobutyric acid is essential for ensuring the purity and stability of pharmaceutical products. Molnupiravir, for instance, is an antiviral drug approved by the FDA to treat COVID-19. Isobutyric acid is a known impurity that may be present in Molnupiravir formulations due to the synthesis process or degradation over time. Isobutyric acid can irritate the lungs. Repeated exposure may cause bronchitis to develop with cough, phlegm, and/or shortness of breath. The current study is the first study for isobutyric acid determination used carbon paste electrodes. Tetradodecyl ammonium chloride surfactant (TDAC) used as ionophore in a quality-by-design approach to develop and optimize a carbon-paste sensor for isobutyric acid . Twenty-one sensors with different compositions were tested, and the results were computationally analyzed to generate prediction models. Using the prediction models, the function predicted with 96.7% desirability that a sensor containing 16.85% ion-exchanger, 0% graphene, and o-NPOE as a plasticizer would achieve a Nernstian slope of 57.035 mV/decade, an R-squared approaching unity, and a response time of 6.2 seconds. The sensor accurately measured isobutyric acid concentrations within a wide linear range (9.0×10-8 –1.0×10-2 mol L-1) with high sensitivity and selectivity. The sensor’s morphologya and compostion were examined using the scanning electron microscope and energy-dispersive X-ray analysis. Isobutyric acid was determined in different smamples like waste water, urine and plasma and spiked Molnupiravir standard samples. Molnupiravir thermal stability also was examined using proposed electrode. The results obtained from electrochemical method was compared with data obtained from HPLC method.
- 25 October 2024
- Published by Springer Nature in Research Square
Open AccessExperimentally designed sensor for the real-time detection of Molnupiravir degradation: Optimization, Characterization, and Application"
Isobutyric acid is short-chain fatty acid. In pharmaceutical analysis, quantifying isobutyric acid is essential for ensuring the purity and stability of pharmaceutical products. Molnupiravir, for instance, is an antiviral drug approved by the FDA to treat COVID-19. Isobutyric acid is a known impurity that may be present in Molnupiravir formulations due to the synthesis process or degradation over time. Isobutyric acid can irritate the lungs. Repeated exposure may cause bronchitis to develop with cough, phlegm, and/or shortness of breath. The current study is the first study for isobutyric acid determination used carbon paste electrodes. Tetradodecyl ammonium chloride surfactant (TDAC) used as ionophore in a quality-by-design approach to develop and optimize a carbon-paste sensor for isobutyric acid . Twenty-one sensors with different compositions were tested, and the results were computationally analyzed to generate prediction models. Using the prediction models, the function predicted with 96.7% desirability that a sensor containing 16.85% ion-exchanger, 0% graphene, and o-NPOE as a plasticizer would achieve a Nernstian slope of 57.035 mV/decade, an R-squared approaching unity, and a response time of 6.2 seconds. The sensor accurately measured isobutyric acid concentrations within a wide linear range (9.0×10-8 –1.0×10-2 mol L-1) with high sensitivity and selectivity. The sensor’s morphologya and compostion were examined using the scanning electron microscope and energy-dispersive X-ray analysis. Isobutyric acid was determined in different smamples like waste water, urine and plasma and spiked Molnupiravir standard samples. Molnupiravir thermal stability also was examined using proposed electrode. The results obtained from electrochemical method was compared with data obtained from HPLC method.
- 1 September 2024
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 20 (9) , 646-662
A New Modified Carbon Paste Electrode for Selective Determination of Chromium(III) in Pharmaceutical Drugs and Food Samples
Background and Objective: This study presents a novel potentiometric method for the precise, accurate, selective, and rapid determination of Cr(III) ion concentration in different samples. Methods: A new ionophore, namely macrocyclic tetramide ionophore (MCTA), was synthesized through an inexpensive and straightforward approach, yielding a high-quality product. The (MCTA) ionophore was utilized as the active center in the preparation of modified carbon paste electrodes (MCPEs) to quantify the Cr(III) ion. The paste was made by adding graphite, MCTA, and plasticizer and mixing them in varying weight percent ratios. Results: The proposed electrodes, I and II, exhibited a trivalent Nernstian response of 20.029 ±0.57 and 20.3±0.56 mV decade-1 , respectively, with linearity of 1.0x10-7 – 1.0x10-2 and 1.0x10-5 – 1.0x10- 2 mol L-1 . Electrodes I and II were examined for their pH, response time, and thermal stability. In comparison to other mono-, bi-, and trivalent cations, starch, and sugars, the electrodes demonstrated a high degree of selectivity for Cr(III). The modified electrodes were used to determine the concentration of Cr(III) in various real samples, including drug tablets, juice extractions, and tap water, with acceptable recovery values. Conclusion: The results were compared with those obtained using the previously reported method, with no significant difference observed between them, as indicated by the F and t-test values. The data showed good accuracy and precision, as well as a high percentage of recovery. The adsorption capacity of the MCTA ionophore towards Cr(III) ions was also examined.
- 1 September 2024
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 20 (9) , 646-662
A New Modified Carbon Paste Electrode for Selective Determination of Chromium(III) in Pharmaceutical Drugs and Food Samples
Background and Objective: This study presents a novel potentiometric method for the precise, accurate, selective, and rapid determination of Cr(III) ion concentration in different samples. Methods: A new ionophore, namely macrocyclic tetramide ionophore (MCTA), was synthesized through an inexpensive and straightforward approach, yielding a high-quality product. The (MCTA) ionophore was utilized as the active center in the preparation of modified carbon paste electrodes (MCPEs) to quantify the Cr(III) ion. The paste was made by adding graphite, MCTA, and plasticizer and mixing them in varying weight percent ratios. Results: The proposed electrodes, I and II, exhibited a trivalent Nernstian response of 20.029 ±0.57 and 20.3±0.56 mV decade-1 , respectively, with linearity of 1.0x10-7 – 1.0x10-2 and 1.0x10-5 – 1.0x10- 2 mol L-1 . Electrodes I and II were examined for their pH, response time, and thermal stability. In comparison to other mono-, bi-, and trivalent cations, starch, and sugars, the electrodes demonstrated a high degree of selectivity for Cr(III). The modified electrodes were used to determine the concentration of Cr(III) in various real samples, including drug tablets, juice extractions, and tap water, with acceptable recovery values. Conclusion: The results were compared with those obtained using the previously reported method, with no significant difference observed between them, as indicated by the F and t-test values. The data showed good accuracy and precision, as well as a high percentage of recovery. The adsorption capacity of the MCTA ionophore towards Cr(III) ions was also examined.
- Open Access
Graphitic Carbon Nitride/MOFs Hybrid Composite as Highly Selective and Sensitive Electrodes for Calcium Ion Detection
The metal–organic framework (MOF) is a class of materials that exhibits a notable capacity for electron transfer. This unique framework design offers potential applications in various fields, including catalysis, gas storage, and sensing. Herein, we focused on a specific type of MOF called Ti-MOF. To enhance its properties and functionality, the composite material was prepared by incorporating graphitic carbon nitride (g-C3N4) into the Ti-MOF structure. This composite, known as g-C3N4@Ti-MOF, was selected as the active material for ion detection, specifically targeting calcium ions (Ca2+). To gain a comprehensive understanding of the structural and chemical properties of the g-C3N4@Ti-MOF composite, several analytical techniques were employed to characterize the prepared g-C3N4@Ti-MOF composite, including X-ray diffraction (XRD), SEM-EDX, and FT-IR. For comparison, different pastes were prepared by mixing Ti-MOF or g-C3N4@Ti-MOF, graphite, and o-NPOE as a plasticizer. The divalent Nernstian responses of the two best electrodes, I and II, were 28.15 ± 0.47 and 29.80 ± 0.66 mV decade−1, respectively, with concentration ranges of 1 µM–1 mM and 0.1 µM–1 mM with a content 1.0 mg Ti-MOF: 250 mg graphite: 0.1 mL o-NPOE and 0.5 mg g-C3N4@Ti-MOF: 250 mg graphite: 0.1 mL o-NPOE, respectively. The electrodes showed high sensitivity and selectivity for Ca2+ ions over different species. The suggested electrodes have been successfully employed for Ca2+ ion measurement in various real samples with excellent precision (RSD = 0.74–1.30%) and accuracy (recovery = 98.5–100.2%), and they exhibited good agreement with the HPLC.
Open AccessGraphitic Carbon Nitride/MOFs Hybrid Composite as Highly Selective and Sensitive Electrodes for Calcium Ion Detection
The metal–organic framework (MOF) is a class of materials that exhibits a notable capacity for electron transfer. This unique framework design offers potential applications in various fields, including catalysis, gas storage, and sensing. Herein, we focused on a specific type of MOF called Ti-MOF. To enhance its properties and functionality, the composite material was prepared by incorporating graphitic carbon nitride (g-C3N4) into the Ti-MOF structure. This composite, known as g-C3N4@Ti-MOF, was selected as the active material for ion detection, specifically targeting calcium ions (Ca2+). To gain a comprehensive understanding of the structural and chemical properties of the g-C3N4@Ti-MOF composite, several analytical techniques were employed to characterize the prepared g-C3N4@Ti-MOF composite, including X-ray diffraction (XRD), SEM-EDX, and FT-IR. For comparison, different pastes were prepared by mixing Ti-MOF or g-C3N4@Ti-MOF, graphite, and o-NPOE as a plasticizer. The divalent Nernstian responses of the two best electrodes, I and II, were 28.15 ± 0.47 and 29.80 ± 0.66 mV decade−1, respectively, with concentration ranges of 1 µM–1 mM and 0.1 µM–1 mM with a content 1.0 mg Ti-MOF: 250 mg graphite: 0.1 mL o-NPOE and 0.5 mg g-C3N4@Ti-MOF: 250 mg graphite: 0.1 mL o-NPOE, respectively. The electrodes showed high sensitivity and selectivity for Ca2+ ions over different species. The suggested electrodes have been successfully employed for Ca2+ ion measurement in various real samples with excellent precision (RSD = 0.74–1.30%) and accuracy (recovery = 98.5–100.2%), and they exhibited good agreement with the HPLC.
- 10 December 2021
- Published by Wiley in Electroanalysis
- Vol. 34 (5) , 872-882
Chemical Modified Carbon Paste Electrode for Potentiometric Determination of Mo(VI) and its Application in Food Analysis and Agriculture Fertilizers
- 10 December 2021
- Published by Wiley in Electroanalysis
- Vol. 34 (5) , 872-882
Chemical Modified Carbon Paste Electrode for Potentiometric Determination of Mo(VI) and its Application in Food Analysis and Agriculture Fertilizers