Abstract
The article presents data on the use of epoxy resin as a matrix for creating composite materials with magnetite powder to protect against microwave radiation from domestic and industrial sources. It is shown that epoxy resin, with average reflection values at certain frequencies, contributes to a sharp decrease in reflection (up to -40 dB), and the real part of permeability lies within 2.7 units, the imaginary part is minimal, and magnetic permeability is absent. With a content of 15% and 45% magnetite in the composite material, the reflection of microwave radiation at points of wavelength and sample multiplicity decreases to -30...-20 dB, and the real part of the permeability is 3.25...4 units. With a magnetite powder content of 30% and 60%, sharp jumps in both dielectric and magnetic permeability we observed, which are associated with the uneven distribution of the filler throughout the matrix volume. The values of the real and imaginary parts of the dielectric permeability after approximation are more or less acceptable, but the value of the magnetic permeability they cannot processed mathematically and the microwave radiation reflection is within the range of -27...-22 dB.

This publication has 22 references indexed in Scilit: