Performance comparison of reference current extraction techniques for indirect current control based shunt active filter
- 1 November 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
The shunt active filters play a dominant role for eradication of power quality problems in modern era, where the majority of load has non-linear nature. It is very important for an active filter to acquire accurate reference current extraction technique as the inaccuracy leads to incorrect compensation and lost control over the DC link. In this paper, three significantapproachesnamely the instantaneous power theory (IPT), unit vector control (UVT) and synchronous reference frame theory (SRF) for reference current extraction have been assessed, evaluated and compared. Thesecontrol schemes are based on indirect current control technique (ICC) and in all methods PI controller is used for stabilization of the DC-link voltage. The advantages and limitations of reference current extraction methods found in literature have been also discussed and justified on the basis of MATLAB simulations for current source type of load, voltage source type of load and transient load conditions.Keywords
This publication has 12 references indexed in Scilit:
- A critical review of detection and classification of power quality eventsRenewable and Sustainable Energy Reviews, 2015
- Power Quality Problems and Mitigation Techniques2014
- Comparative analysis on a shunt active power filter with different control strategies for composite loads2014
- Assessing the Performance of a Static Var Compensator for an Electric Arc FurnaceIEEE Transactions on Industry Applications, 2013
- A Digital Signal Processor Based Performance Evaluation of Three-phase Four-wire Shunt Active Filter for Harmonic Elimination, Reactive Power Compensation, and Balancing of Non-linear Loads under Non-ideal Mains VoltagesElectric Power Components and Systems, 2012
- Evaluation of reference current extraction methods for DSP implementation in active power filtersElectric Power Systems Research, 2009
- Control of a 3-phase 4-leg active power filter under non-ideal mains voltage conditionElectric Power Systems Research, 2008
- Design Simulation and Experimental Investigations, on a Shunt Active Power Filter for Harmonics, and Reactive Power CompensationElectric Power Components and Systems, 2003
- Performance comparison of two current control techniques applied to an active filter2002
- A novel, high-frequency, per-phase static VAr compensator2002