Open-source Tracked Ultrasound with Anser EMT
Preprint
Abstract
Image-guided Interventions (IGT) have shown a huge potential to improve medical procedures or even allow for new treatment options. Most ultrasound(US)-based IGT systems use electromagnetic (EM) tracking for localizing US probes and instruments. However, EM tracking is not always reliable in clinical settings because the EM field can be disturbed by medical equipment. So far, most researchers used and studied commercial EM trackers with their IGT systems which in turn limited the possibilities to customize the trackers in order minimize distortions and make the systems robust for clinical use. In light of current good scientific practice initiatives that increasingly request research to publish the source code corresponding to a paper, the aim of this work was to test the feasibility of using the open-source EM tracker Anser EMT for localizing US probes in a clinical US suite for the first time. The standardized protocol of Hummel et al. yielded a jitter of 0.1$\pm$0.1 mm and a position error of 1.1$\pm$0.7 mm, which is comparable to 0.1 mm and 1.0 mm of a commercial NDI Aurora system. The rotation error of Anser EMT was 0.15$\pm$0.16{\deg}, which is lower than at least 0.4{\deg} for the commercial tracker. We consider tracked US as feasible with Anser EMT if an accuracy of 1-2 mm is sufficient for a specific application.Keywords
All Related Versions
This publication has 11 references indexed in Scilit:
- Construction of a conductive distortion reduced electromagnetic tracking system for computer assisted image-guided interventionsMedical Engineering & Physics, 2014
- Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and ApplicationsIEEE Transactions on Medical Imaging, 2014
- Feasibility of the virtual needle tracking system for percutaneous radiofrequency ablation of hepatocellular carcinomaHepatology Research, 2013
- Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generatorInternational Journal of Computer Assisted Radiology and Surgery, 2012
- The case for open computer programsNature, 2012
- Image-Guided Interventions: Technology Review and Clinical ApplicationsAnnual Review of Biomedical Engineering, 2010
- OpenIGTLink: an open network protocol for image‐guided therapy environmentThe International Journal of Medical Robotics and Computer Assisted Surgery, 2009
- Design and application of an assessment protocol for electromagnetic tracking systemsMedical Physics, 2005
- A review of calibration techniques for freehand 3-D ultrasound systemsUltrasound in Medicine & Biology, 2005
- Closed-form solution of absolute orientation using unit quaternionsJournal of the Optical Society of America A, 1987