Alfred Michael Franz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Alfred Michael Franz has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Alexander Seitel
Division of Computer Assisted Medical Interventions German Cancer Research Center (DKFZ) Heidelberg Germany
3 shared publicationsHerman Alexander Jaeger
University College Cork Cork Ireland
2 shared publicationsLena Maier-Hein
Division of Computer Assisted Medical Interventions German Cancer Research Center (DKFZ) Heidelberg Germany
2 shared publicationsB. J. Mittmann
Institute for Computer Science Ulm University of Applied Sciences Ulm Germany
1 shared publicationB. Schmidberger
Institute for Medical Engineering and Mechatronics University of Applied Sciences Ulm Germany
1 shared publicationC. M. Sommer
1 shared publication
Latest Publications
- Open Access
An open-source tool for automated planning of overlapping ablation zones for percutaneous renal tumor treatment
Percutaneous thermal ablation is a minimally-invasive treatment option for renal cancer. To treat larger tumours, multiple overlapping ablations zones are required. Arrangements with a low number of ablation zones but coverage of the whole tumour volume are challenging to find for physicians. In this work, an open-source software tool with a new planning approach based on the automatic selection from a large number of randomized geometrical arrangements is presented. Two uncertainty parameters are introduced to account for tissue shrinking and tolerance of non-ablated tumour volume. For seven clinical renal T1a, T1b and T2a tumours, ablation plans were proposed by the software. All proposals are comparable to manual plans of an experienced physician with regard to the number of required ablation zones.
Open AccessAn open-source tool for automated planning of overlapping ablation zones for percutaneous renal tumor treatment
Percutaneous thermal ablation is a minimally-invasive treatment option for renal cancer. To treat larger tumours, multiple overlapping ablations zones are required. Arrangements with a low number of ablation zones but coverage of the whole tumour volume are challenging to find for physicians. In this work, an open-source software tool with a new planning approach based on the automatic selection from a large number of randomized geometrical arrangements is presented. Two uncertainty parameters are introduced to account for tissue shrinking and tolerance of non-ablated tumour volume. For seven clinical renal T1a, T1b and T2a tumours, ablation plans were proposed by the software. All proposals are comparable to manual plans of an experienced physician with regard to the number of required ablation zones.
- Open Access
Open-source Tracked Ultrasound with Anser EMT
Image-guided Interventions (IGT) have shown a huge potential to improve medical procedures or even allow for new treatment options. Most ultrasound(US)-based IGT systems use electromagnetic (EM) tracking for localizing US probes and instruments. However, EM tracking is not always reliable in clinical settings because the EM field can be disturbed by medical equipment. So far, most researchers used and studied commercial EM trackers with their IGT systems which in turn limited the possibilities to customize the trackers in order minimize distortions and make the systems robust for clinical use. In light of current good scientific practice initiatives that increasingly request research to publish the source code corresponding to a paper, the aim of this work was to test the feasibility of using the open-source EM tracker Anser EMT for localizing US probes in a clinical US suite for the first time. The standardized protocol of Hummel et al. yielded a jitter of 0.1$\pm$0.1 mm and a position error of 1.1$\pm$0.7 mm, which is comparable to 0.1 mm and 1.0 mm of a commercial NDI Aurora system. The rotation error of Anser EMT was 0.15$\pm$0.16{\deg}, which is lower than at least 0.4{\deg} for the commercial tracker. We consider tracked US as feasible with Anser EMT if an accuracy of 1-2 mm is sufficient for a specific application.
Open AccessOpen-source Tracked Ultrasound with Anser EMT
Image-guided Interventions (IGT) have shown a huge potential to improve medical procedures or even allow for new treatment options. Most ultrasound(US)-based IGT systems use electromagnetic (EM) tracking for localizing US probes and instruments. However, EM tracking is not always reliable in clinical settings because the EM field can be disturbed by medical equipment. So far, most researchers used and studied commercial EM trackers with their IGT systems which in turn limited the possibilities to customize the trackers in order minimize distortions and make the systems robust for clinical use. In light of current good scientific practice initiatives that increasingly request research to publish the source code corresponding to a paper, the aim of this work was to test the feasibility of using the open-source EM tracker Anser EMT for localizing US probes in a clinical US suite for the first time. The standardized protocol of Hummel et al. yielded a jitter of 0.1$\pm$0.1 mm and a position error of 1.1$\pm$0.7 mm, which is comparable to 0.1 mm and 1.0 mm of a commercial NDI Aurora system. The rotation error of Anser EMT was 0.15$\pm$0.16{\deg}, which is lower than at least 0.4{\deg} for the commercial tracker. We consider tracked US as feasible with Anser EMT if an accuracy of 1-2 mm is sufficient for a specific application.
- 7 February 2019
- Published by Springer Nature
- p. 232-237
Open-Source Tracked Ultrasound with Anser Electromagnetic Tracking
- 7 February 2019
- Published by Springer Nature
- p. 232-237
Open-Source Tracked Ultrasound with Anser Electromagnetic Tracking
- 10 November 2018
- Published by Wiley in Medical Physics
- Vol. 46 (1) , 15-24
Polhemus EM tracked Micro Sensor for CT‐guided interventions
Purpose: Electromagnetic (EM) tracking is a key technology in image‐guided therapy. A new EM Micro Sensor was presented by Polhemus Inc.; it is the first to enable localization of medical instruments through their trackers. Different field generators (FGs) are available by Polhemus, one being almost as small as a sugar cube. As accuracy and robustness of tracking are known challenges to using EM trackers in clinical environments, the goal of this study was a standardized assessment of the Micro Sensor in both a laboratory (lab) and a computed tomography (CT) environment.Methods: The Micro Sensor was assessed by means of Hummel et al.’s standardized protocol; it was assessed in conjunction with a Polhemus Liberty tracker and three FGs — with edge lengths of 1 (TX1), 2 (TX2), and 4 (TX4) inches. Precision as well as positional and rotational accuracy were determined in a lab and a CT suite. Distortions by four different metallic cylinders and tracking of two typical medical instruments — a hypodermic needle and a flexible endoscope — were also tested.Results: A jitter of 0.02 mm or less was found for all FGs in the different environments, except for the TX2 FG for which no valid data could be obtained in the CT. Errors of 5 cm distance measurements were 0.6 mm or less for all FGs in the lab. While the distance errors of the TX1 FG were only slightly increased up to 1.6 mm in the CT, those of the TX4 FG were found to be up to around 10% of the measured distance (5.4 mm on average). The mean orientation error was found to be 0.9°/0.5°/0.1° for the TX4/TX2/TX1 FG in the lab. In the CT environment, rotation errors were in the same range: less than 1.2°/0.1° for the TX4/TX1 FG. Deviation under the presence of metallic cylinders stayed below 1 mm in most cases. Precision and orientational accuracy do not seem to be affected by instrument tracking and stayed in the same range as for the other measurements whereas distance errors were slightly increased up to 1.7 mm.Conclusion: This study shows that accurate tracking of medical instruments is possible with the new Micro Sensor; it demonstrated a jitter of 0.01 mm or less, position errors below 2 mm, and rotation errors of less than 0.3°. As with other EM trackers, errors increase when large tracking volumes with ranges of up to 50 cm are required in clinical environments. For smaller tracking volumes with ranges of up to 15 cm, a high accuracy and robustness was found. This is interesting especially for the TX1 FG which can easily be placed in close vicinity to the region of interest.
- 10 November 2018
- Published by Wiley in Medical Physics
- Vol. 46 (1) , 15-24
Polhemus EM tracked Micro Sensor for CT‐guided interventions
Purpose: Electromagnetic (EM) tracking is a key technology in image‐guided therapy. A new EM Micro Sensor was presented by Polhemus Inc.; it is the first to enable localization of medical instruments through their trackers. Different field generators (FGs) are available by Polhemus, one being almost as small as a sugar cube. As accuracy and robustness of tracking are known challenges to using EM trackers in clinical environments, the goal of this study was a standardized assessment of the Micro Sensor in both a laboratory (lab) and a computed tomography (CT) environment.Methods: The Micro Sensor was assessed by means of Hummel et al.’s standardized protocol; it was assessed in conjunction with a Polhemus Liberty tracker and three FGs — with edge lengths of 1 (TX1), 2 (TX2), and 4 (TX4) inches. Precision as well as positional and rotational accuracy were determined in a lab and a CT suite. Distortions by four different metallic cylinders and tracking of two typical medical instruments — a hypodermic needle and a flexible endoscope — were also tested.Results: A jitter of 0.02 mm or less was found for all FGs in the different environments, except for the TX2 FG for which no valid data could be obtained in the CT. Errors of 5 cm distance measurements were 0.6 mm or less for all FGs in the lab. While the distance errors of the TX1 FG were only slightly increased up to 1.6 mm in the CT, those of the TX4 FG were found to be up to around 10% of the measured distance (5.4 mm on average). The mean orientation error was found to be 0.9°/0.5°/0.1° for the TX4/TX2/TX1 FG in the lab. In the CT environment, rotation errors were in the same range: less than 1.2°/0.1° for the TX4/TX1 FG. Deviation under the presence of metallic cylinders stayed below 1 mm in most cases. Precision and orientational accuracy do not seem to be affected by instrument tracking and stayed in the same range as for the other measurements whereas distance errors were slightly increased up to 1.7 mm.Conclusion: This study shows that accurate tracking of medical instruments is possible with the new Micro Sensor; it demonstrated a jitter of 0.01 mm or less, position errors below 2 mm, and rotation errors of less than 0.3°. As with other EM trackers, errors increase when large tracking volumes with ranges of up to 50 cm are required in clinical environments. For smaller tracking volumes with ranges of up to 15 cm, a high accuracy and robustness was found. This is interesting especially for the TX1 FG which can easily be placed in close vicinity to the region of interest.
- 17 August 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (9) , 1309-1310
Guest editorial for the IJCARS special issue on MICCAI 2017
- 17 August 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (9) , 1309-1310
Guest editorial for the IJCARS special issue on MICCAI 2017