Percutaneous Aortic Valve Replacement
Authors:
Open Access
- 1 January 2008
- journal article
- research article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 3 (1) , 27-32
Abstract
To improve the outcome of percutaneous valve replacement in aortic stenosis endovascular resection of calcified aortic valves will be necessary. In this study different sealing methods were evaluated. The focus of this research was feasibility and mechanical functionality in human anatomy. The aortic valve isolation chamber (AVIC) is a catheter-based system to seal the aortic valve during resection, and was installed antegrade and retrograde. Firstly, AVIC was inserted antegrade via the cardiac apex in human postmortem models (n = 2), and secondly in porcine in vivo models under extra corporeal circulation (n = 5). Endoscopic inspection of the valve was recorded. AVIC was installed via a port system through the descending aorta. Micro- and macropathologies were performed. AVIC transapical deployment in the two human models took 3 and 4 minutes respectively and 2.2 ± 1.3 minutes in average in the porcine model. From the descending aorta, the deployment took 9.3 ± 5.5 minutes. Fluoroscopy and macroscopy demonstrated sealed chambers. Microscopic and histologic analysis demonstrated no profound damages of the surrounding tissue. This study demonstrates the feasibility of transapical and retrograde endovascular sealing of the aortic valve in vitro and in vivo in nonbeating hearts.Keywords
This publication has 19 references indexed in Scilit:
- Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro studyEuropean Journal of Cardio-Thoracic Surgery, 2007
- Aortic valve surgery: time to be open-minded and to rethinkEuropean Journal of Cardio-Thoracic Surgery, 2007
- Transapical transcatheter aortic valve implantation.European Journal of Cardio-Thoracic Surgery, 2007
- Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve DiseaseCirculation, 2006
- Port-Access Aortic Valve Surgery: A Technique in EvolutionThe Heart Surgery Forum, 2004
- Percutaneous Valve Replacement: Current State and Future ProspectsThe Annals of Thoracic Surgery, 2004
- Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosisJACC, 2004
- Acute retrograde aortic dissection during endovascular repair of a thoracic aortic aneurysmThe Annals of Thoracic Surgery, 2003
- Emergency surgery for retrograde extension of type B dissection after endovascular stent graft repairEuropean Journal of Cardio-Thoracic Surgery, 2001
- Percutaneous balloon aortic valvuloplasty. Acute and 30-day follow-up results in 674 patients from the NHLBI Balloon Valvuloplasty Registry.Circulation, 1991