RQRené Quaden

René Quaden

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


René Quaden has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 August 2009
      • Vol. 67  (8) , 865-73

    Does patient-prosthesis mismatch influence the results of combined aortic valve replacement and coronary bypass grafting?

    by Wojciech Mrówczyński, Georg Lutter, Tim Attmann, Grischa Hoffmann, Rene Quaden, Jochen Cremer, Andreas Böning

    Combined aortic valve replacement and coronary revascularisation is becoming more frequent. Patient-prosthesis mismatch (PPM) as an additional risk factor may potentially affect the early and late outcome. To evaluate the impact of PPM on early and mid-term clinical results including quality of life in patients undergoing combined surgical treatment of coronary artery disease and aortic valve defects. Medical records of 309 consecutive patients referred for combined surgery were reviewed. Patients were divided into three groups according to the presence of moderate or severe PPM (defined by aortic valve effective orifice area index in the range 0.85-0.65 cm2/m2 and smaller than 0.65 cm2/m2, respectively) or absence of PPM. The demographic and perioperative data, and early and late survival, as well as quality of life (SF-36) were analysed. The presence of severe PPM was found in 51 (16.5%) patients, whereas moderate PPM--in 153 (49.5%) patients. Patients from both PPM groups were significantly older than those without PPM. Subjects with severe PPM had higher weight and body mass index. They frequently had dyslipidaemia and both PPM groups received a biological valve more often than patients without PPM (94.1 and 77.1 vs. 19.1%, p<0.0001). There was no significant difference between all groups regarding early or late mortality. Advanced age, renal insufficiency and arrhythmia were predictors of early death. Late survival was determined only by number of postoperative complications in a Cox regression model. There was no difference in any components of the SF-36 survey between all groups. PPM is a frequent phenomenon in older patients requiring aortic valve replacement and revascularisation. Severe PPM occurs rarely, predominantly in obese patients. However, its presence does not affect early and late survival or quality of life.


  • Open Access

    Chronic type A dissection of the ascending aorta

    by René Quaden, Tim Hümme, Jochen Cremer, Aziz Rahimi

    A chronic type A dissection was observed in a 56-year-old woman during a diagnostic CT imaging (Fig. 1A–C ). Typical pain occurred more than 5 years ago. Intraoperatively, a pale thrombus was found and removed (Fig. 1D–E). The operation was successfully performed and the patient was discharged after 10 days.


  • Open Access

    Percutaneous Aortic Valve Replacement

    by René Quaden, Tim Attmann, Günther-Rudolf Klaws, Michael Schünke, Dirk Theisen-Kunde, Lucian Lozonschi, Jochen Cremer, Georg Lutter

    To improve the outcome of percutaneous valve replacement in aortic stenosis endovascular resection of calcified aortic valves will be necessary. In this study different sealing methods were evaluated. The focus of this research was feasibility and mechanical functionality in human anatomy. The aortic valve isolation chamber (AVIC) is a catheter-based system to seal the aortic valve during resection, and was installed antegrade and retrograde. Firstly, AVIC was inserted antegrade via the cardiac apex in human postmortem models (n = 2), and secondly in porcine in vivo models under extra corporeal circulation (n = 5). Endoscopic inspection of the valve was recorded. AVIC was installed via a port system through the descending aorta. Micro- and macropathologies were performed. AVIC transapical deployment in the two human models took 3 and 4 minutes respectively and 2.2 ± 1.3 minutes in average in the porcine model. From the descending aorta, the deployment took 9.3 ± 5.5 minutes. Fluoroscopy and macroscopy demonstrated sealed chambers. Microscopic and histologic analysis demonstrated no profound damages of the surrounding tissue. This study demonstrates the feasibility of transapical and retrograde endovascular sealing of the aortic valve in vitro and in vivo in nonbeating hearts.


  • Open Access

    Editorial comment

    by René Quaden, Georg Lutter

    First, we would like to congratulate Flecher et al. [1] for their work—an important contribution to basic research on percutaneous aortic valve technologies. Unfortunately, interest on basic research in this field seems to have decreased since the human clinical trials began. But despite the clinical accomplishment of percutaneous valve technologies in the last 5 years, many problems are yet unsolved [2].


  • Advances in Experimental Percutaneous Pulmonary Valve Replacement

    by Tim Attmann, Thomas Jahnke, René Quaden, Andreas Boening, Stefan Muller-Hulsbeck, Jochen Cremer, Georg Lutter


  • Open Access

    Percutaneous aortic valve replacement: resection before implantation?

    by René Quaden, Tim Attmann, Andreas Boening, Jochen Cremer, Georg Lutter

    Objective: After transluminal endovascular implantation of a new valved stent, the aim of this study was to evaluate the feasibility of using a high-pressure water stream to endovascularly resect human calcified aortic valves. Methods: First, human calcified aortic valves were excised and then resected in vitro to determine optimal water jet parameters. Second, healthy porcine aortic valves were ablated in vitro to evaluate possible destruction to the surrounding anatomy. Third, resection was performed endoluminally by introducing microsystemic tools into the descending aorta, passing them through the arch and ascending aorta to the aortic valve in an in vitro porcine model. Macro- and micropathology of specimens were analyzed. Results: First, resection of human calcified valves took a mean of 6.0±2.4min per three leaflets at 150bar (n=17). The maximum size of the cut leaflets was 7.1±1.7mm. Second, resection of healthy porcine aortic valves at 60bar took 2.3±0.3min per three leaflets (n=10). Only the aortic annulus was moderately affected in six cases. Third, endoluminal resection via the descending aorta took 12.2±0.8min per three leaflets at 60bar (n=10). The aortic wall was affected in four cases, the aortic annulus and the coronary ostia only once. Microscopic analysis also revealed superficial lesions with a maximum lesion depth of 1200μm in one case, and an average of 580±145μm in subsequent lesions. The mitral valve and the left ventricular outflow tract were not affected. Conclusions: Percutaneous resection of heart valves is emerging as a promising auxiliary method for the resection of calcified aortic heart valves because they can be cut endoscopically. Nonetheless, before this resection tool can be clinically applied by surgeons to perform a true percutaneous valve replacement, an additional aortic valve resection chamber (already at the prototype stage) designed for capturing all debris, has to be established.