Effect of Low Versus High Tidal-Volume Total Liquid Ventilation on Pulmonary Inflammation
Open Access
- 18 June 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 11, 603
Abstract
Animal experiments suggest that total liquid ventilation (TLV) induces less ventilator-induced lung injury (VILI) than conventional mechanical gas ventilation. However, TLV parameters that optimally minimize VILI in newborns remain unknown. Our objective was to compare lung inflammation between low (L-VT) and high (H-VT) liquid tidal volume and evaluate impacts on the weaning process. Sixteen anesthetized and paralyzed newborn lambs were randomized in an L-VT group (initial tidal volume of 10 mL/kg at 10/min) and an H-VT group (initial tidal volume of 20 mL/kg at 5/min). Five unventilated newborn lambs served as controls. After 4 h of TLV in the supine position, the lambs were weaned in the prone position for another 4 h. The levels of respiratory support needed during the 4 h post-TLV were compared. The anterior and posterior lung regions were assessed by a histological score and real-time quantitative PCR for IL1B, IL6, and TNF plus 12 other exploratory VILI-associated genes. All but one lamb were successfully extubated within 2 h post-TLV (72 ± 26 min vs. 63 ± 25 min, p = 0.5) with similar FiO2 at 4 h post-TLV (27 ± 6% vs. 33 ± 7%, p = 0.3) between the L-VT and H-VT lambs. No significant differences were measured in histological inflammation scores between L-VT and H-VT lambs, although lambs in both groups exhibited slightly higher scores than the control lambs. The L-VT group displayed higher IL1B mRNA expression than the H-VT group in both anterior (2.8 ± 1.5-fold increase vs. 1.3 ± 0.4-fold increase, p = 0.02) and posterior lung regions (3.0 ± 1.0-fold change increase vs. 1.1 ± 0.3-fold increase, p = 0.002), respectively. No significant differences were found in IL6 and TNF expression levels. Gene expression changes overall indicated that L-VT was associated with a qualitatively distinct inflammatory gene expression profiles compared to H-VT, which may indicate different clinical effects. In light of these findings, further mechanistic studies are warranted. In conclusion, we found no advantage of lower tidal volume use, which was in fact associated with a slightly unfavorable pattern of inflammatory gene expression.Keywords
Funding Information
- Santé (0000)
This publication has 43 references indexed in Scilit:
- Clinical Effectiveness and Safety of Permissive HypercapniaClinics in Perinatology, 2012
- Total liquid ventilation efficacy in an ovine model of severe meconium aspiration syndromeCritical Care Medicine, 2011
- Total Liquid Ventilation Provides Superior Respiratory Support to Conventional Mechanical Ventilation in a Large Animal Model of Severe Respiratory FailureASAIO Journal, 2011
- Airway Injury From Initiating Ventilation in Preterm SheepPediatric Research, 2010
- High-throughput quantification of splicing isoformsRNA, 2009
- Optimal Expiratory Volume Profile in Tidal Liquid Ventilation under Steady State Conditions, Based on a Symmetrical Lung ModelASAIO Journal, 2009
- Multicenter Comparative Study of Conventional Mechanical Gas Ventilation to Tidal Liquid Ventilation in Oleic Acid Injured SheepASAIO Journal, 2008
- Effects of respiratory rate on ventilator-induced lung injury at a constant Paco2 in a mouse model of normal lungCritical Care Medicine, 2008
- Effect of Repeated Induced Airway Collapse During Total Liquid VentilationASAIO Journal, 2007
- A numerical and experimental study of compliance and collapsibility of preterm lamb tracheaeJournal of Biomechanics, 2004