Measurements of total body water with a foot-to-foot impedancemeter
- 12 July 2007
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 30 (4) , 483-489
Abstract
The objective was to set-up a method for measuring total body water volumes (TBW) using a Tefal foot-to-foot impedancemeter (FFI) by comparison with a multifrequency medical impedancemeter and to validate this method against deuterium dilution data. The investigation was carried out in 57 Caucasian adult subjects. Impedancemeters were a Tefal Bodymaster Vision (foot-to-foot) featuring a square wave signal and a Xitron Hydra 4200 (5-1000 kHz) using BIS method. TBW was measured by the Xitron using a new method that we have developed which applies the BIS method directly to extra and intracellular fluids combined. Although the high frequency impedance of the FFI (R(hf)) was higher than the Xitron infinite frequency resistance and corresponded to a frequency around 100 kHz, TBW differences between the FFI and Xitron were not significant, 0.17+/-2.17 L for men (P=0.694) and 0.04+/-1.88 L for women (P=0.902). Then, our method was tested on another Caucasian population in which R(hf) had been measured with the same FFI, together with TBW measurements by deuterium dilution. TBW differences between the FFI and dilution were -0.38+/-2.27 L for men (P=0.237) and -0.72+/-2.37 L for women (P=0.06). Our method permits, at least in a Caucasian healthy population, to measure TBW using this FFI with the same accuracy as a whole body multifrequency medical impedancemeter, and the measurement, made in upright position, is much quicker.Keywords
This publication has 12 references indexed in Scilit:
- Evaluation of a foot-to-foot impedance meter measuring extracellular fluid volume in addition to fat-free mass and fat tissue massNutrition, 2005
- Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescentsBritish Journal of Nutrition, 2003
- Evaluation of a foot-to-foot bioelectrical impedance analyser in highly active, moderately active and less active young menBritish Journal of Nutrition, 2002
- Dual-Energy X-ray absorptiometry and body composition: differences between devices and comparison with reference methodsNutrition, 2002
- Single- and multifrequency models for bioelectrical impedance analysis of body water compartmentsJournal of Applied Physiology, 1999
- Use of the leg-to-leg bioelectrical impedance method in assessing body-composition change in obese womenThe American Journal of Clinical Nutrition, 1999
- Human hydrometry: comparison of multifrequency bioelectrical impedance with2H2O and bromine dilutionJournal of Applied Physiology, 1998
- Bioimpedance spectrometry in the determination of body water compartments: Accuracy and clinical significanceApplied Radiation and Isotopes, 1998
- Predicting body cell mass with bioimpedance by using theoretical methods: a technological reviewJournal of Applied Physiology, 1997
- Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact foot-pad electrodesMedicine & Science in Sports & Exercise, 1997