The Choice of Energy Efficient Thermal Protection of Office Buildings with Different Internal Heat Intake
Authors:
Open Access
- 31 December 2018
- conference paper
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 463 (2) , 022094
Abstract
The annual energy consumption of the building is greatly influenced by the internal heat intake to the premises. Under heating the incoming heat plays a positive role. During the working day, it compensates the heat losses partly or in full. As far as the cooling is concerned, the thermal emissions in the building play a negative role and the specific need for cold increases with the increase in the specific heat emissions. The aim of the study was to identify the dependence of the annual thermal consumption for heating, as well as the needs in cold for natural and artificial cooling of the building, from various factors, such as the shape of the building and its thermal protection. In annual terms, the load on natural and artificial cooling systems is less in the buildings with the lowest thermal protection and with smaller heat access into the room. It is also interesting, that the cooling load is less when the facade is more glazed, since the heat protection of the building is reducing, which only confirms the previous thesis (the heat access from the solar radiation is usually minimal, since the windows in the buildings with cooling are shaded). The smaller the building in volume is, the higher the heat the lowest energy consumption during the year is achieved with the greatest heat insulation. The ratio between the consumption of heat and cold during the year is also an important information, as the cooling of the building requires 3 to 4 times more primary fuel than heating.Keywords
This publication has 9 references indexed in Scilit:
- Study of transient current measurement using micro-CAP circuit simulator2016
- Data and analytics to inform energy retrofit of high performance buildingsApplied Energy, 2014
- Laboratory thermal transmittance assessments of homogeneous building elements using infrared thermography2014
- Technical note: Airtightness of older-generation energy-efficient houses in SaskatoonJournal of Building Physics, 2012
- Thermal performance of an insulated roof with reflective insulation: Field tests under hot climatic conditionsJournal of Building Physics, 2012
- Performance evaluation of an attic radiant barrier system using three-dimensional transient finite element methodJournal of Building Physics, 2012
- Comparison between predicted and actual energy performance for winter heating in high-performance residential buildings in the Lombardy region (Italy)Energy and Buildings, 2012
- Thermal comfort models: A review and numerical investigationBuilding and Environment, 2012
- Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopesApplied Energy, 2011