AFAnastasiya Frolova

Anastasiya Frolova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anastasiya Frolova has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Dmitry Frolov

    Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, 129337 Moscow, Russia

    2 shared publications
  • E G Malyavina

    Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, Moscow, 129337, Russia

    2 shared publications
  • Elena Malyavina

    Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, Moscow, 129337, Russia

    2 shared publications
  • Alla Lebediuk

    Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, 129337 Moscow, Russia

    1 shared publication
  • Anastasia Bobrovskaya

    Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, Moscow, 129337, Russia

    1 shared publication
  • Denis Karpov

    Vologda State University

    1 shared publication

Latest Publications

  • Open Access

    Thermal imaging survey of general education institutions in Moscow

    by A. A. Frolova, D. F. Karpov, Kh. M. Vafaeva, Z. A. Gaevskaya

    Objective. The aim of the study is to determine the causes of the formation of an uncomfortable microclimate in the school premises on the 1st floor (option 1), as well as to examine the school facade (option 2) using thermal imaging and temperature measuring devices inside the building.Method. Аssessment of the building's structural design; external visual inspection of the building's external enclosures; thermal imaging survey using Testo 868 and Testo 870-1 thermal imagers; additional measurements of indoor air temperature and recording of meteorological conditions using a Testo 435 multifunctional measuring device with an air temperature probe; processing of the obtained thermograms.Result. As a result of the measurements, thermograms were obtained inside the problematic rooms in the first school and on the facades of the buildings in the second school, as well as the values of the internal and external air temperature.Conclusion. Thermal imaging revealed defects in the school facade according to option 2 and reasons for the uncomfortable stay of people on the 1st floor of the school according to option 1. Insufficient thermal protection of buildings was revealed due to poor insulation of enclosing structures, uninsulated entrance doors without a vestibule, which leads to condensation of moisture on the inner surface of the outer wall and door, as well as uncomfortable microclimate conditions in the premises. It was revealed that sunny weather in the cold season affects thermal imaging and does not allow measurements to be taken correctly, even taking into account that the amount of thermal energy from solar radiation at this time of year is insignificant.


  • Open Access

    RETRACTED: Experimental determination of the thermal conductivity of building materials under operating conditions

    by Anastasiya Frolova, Ilya Ledovskikh, Kirill Panin, Eldar Ramazanov

    See the retraction notice E3S Web of Conferences 549, 00001 (2024), https://doi.org/10.1051/e3sconf/202454900001


  • Open Access

    Design of a smoke protection system for a closed car park

    by Anastasiya Frolova, Karolina Sorokina, Dmitry Frolov

    Today, this topic is relevant due to the fact that smoke and toxic combustion products that are released during fires are the main cause of death. According to statistics, about 42% of victims of smoke exposure get severe poisoning, eventually leading to death. At the same time, 70% of all those killed in a fire die precisely from the effects of smoke. The article discusses two types of smoke removal systems for closed car parks (traditional and impulse), analyzes the design features of these systems, performs calculations and evaluates the profitability of these systems in terms of energy consumption and economic costs.

  • Open Access

    Formation of the territorial cost of electricity in the Russian Federation for the economic evaluation of HVAC systems

    by Anastasiya Frolova, Vladislav Prikhodko, Maria Zhernosek

    Comparison of various energy-saving technologies used in the systems of heat and gas supply, ventilation and thermal protection of the building is associated with the mandatory economic justification of the options under consideration (with and without energy-saving measures). According to the economic calculation, the cost of energy resources has the main influence on the profitability of the option. On the territory of the Russian Federation in various areas, for different categories of consumers, their own tariffs are set for the cost of energy resources. This article has collected, systematized and obtained data on the dynamics of changes in the cost of electricity for various tariffs for consumers equated to the population in various regions of the Russian Federation, which in the future simplifies the economic assessment of energy saving measures in DHW systems.


  • Open Access

    The required level of thermal protection of enclosing structures of administrative buildings in the transport infrastructure in Russia and European countries

    by Anastasiya Frolova, Gleb Petrov, Dmitry Frolov, Alla Lebediuk

    Comparison of various standard values and calculation methods adopted in Russia and European countries has always aroused quite a lot of interest, and many works are devoted to this topic. However, the last comparisons were carried out quite a long time ago, and the purpose of this study is to compare the required level of thermal protection of the building envelopes of administrative buildings in the transport infrastructure in Russia and European countries according to the current regulatory documents to determine the ratio of these values to each other. The normalized values of the level of thermal protection of external enclosing structures are related to the degree-days of the heating period. Moreover, the definition of this value in Russia and the EU countries differ from each other. And it is possible to compare the level of thermal protection of enclosing structures in different countries only according to the same characteristic, that is, with the same (or very close) value of the degree-day of the heating period. Also, the level of required resistance to heat transfer of external enclosing structures in Russia is set taking into account heat-conducting inclusions in the enclosing structure, and in European countries without taking into account. That is, it is impossible to compare these two quantities in the original form - you need to take into account the design of the outer shell of the building.


  • Open Access

    The influence of the climatic features of the construction area on the level of economical-efficient thermal protection of the office buildings

    by Anastasya Frolova, Elena Malyavina

    Now, the thermal protection of buildings is determined by the assessment of the heat consumption for heating and ventilation of buildings during the cold period, which should not exceed the energy consumption norms chosen by a volitional means. At the same time, the economic indicators of the operation of engineering systems serving the building are not taken into account, and energy costs for maintaining the thermal microclimate in the warm season are not considered. The economic assessment of the thermal protection of a building should take into account the year-round operating costs of maintaining a thermal microclimate in it and the capital costs of the systems themselves and their connection to power supply networks. These costs are in antiphase with the capital costs of building insulation, which increase with the strengthening of thermal protection. Since building insulation is a very expensive part of construction, it is important to determine its economically feasible level, taking into account the cost of all the listed costs in the conditions of the climate of the construction area and territorial economic indicators.


  • Open Access

    The influence of the climatic features of the construction area on the level of energy-efficient thermal protection of of the office buildings

    by A A Frolova, E G Malyavina

    The choice of the level of the building thermal protection should be based on economic indicators of these buildings, taking into account the cost of maintaining a given room thermal microclimate. However, an economic calculation can only be performed after evaluating the impact of the thermal protection level on the building energy performance. The specific energy consumption of a building is affected by the size of the building, since in the buildings of different lengths and number of storeys, the ratio of ordinary rooms on the intermediate and the upper floors is different, as is the number of ordinary and corner rooms. The purpose of the article is to identify the energy consumption for heating, free and machine cooling of the buildings of various sizes and number of storeys in the areas which differ by the heating period duration and the solar radiation intensity, i.e. in Moscow and in Astrakhan. Three options of the building thermal protection have been considered herewith, differing from each other in the resistance to heat transfer of the outer wall and the coating. The area of the windows made 55% of the facade area. The calculation has been performed for several values of the outdoor air temperature during the year in each city.

  • Open Access

    Influence of the Premises Dustiness Degree in an Educational Institution on the Choice of the Appropriate Air Filter Type

    by Anastasia Frolova, Maxim Belyy, Anastasia Bobrovskaya

    Students and teachers spend about 70% of the day in educational institutions. Therefore, recently in the world studies of the effect of air quality on human well-being and human performance have been conducted more often. The high content of suspended particles in the indoor air can lead to the development of allergies, and also serves as a factor of the transmission of respiratory viral infections. The purpose of this study was to determine the degree of dust in the indoor air in the classrooms. For this purpose, the photoelectric method of registration of aerosol particles and the Koch method were used. The results were evaluated according to two requirements for the amount of suspended particles in the air of the educational institution. Depending on the amount of suspended particles and their size, recommendations were given for filters to reduce the dust content of the internal air.

  • Open Access

    Influence of Solar Radiation Heat Input into Room on Level of Economically-efficient Thermal Protection of Building

    by Elena Malyavina, Anastasia Frolova

    Techniques for choosing an energy and economically feasible thermal protection of buildings in the climatic conditions of Moscow are discussed earlier. An important basis of these techniques is that it was possible to identify the thermal parameters on the basis of which the generalization of the basic energy and economic indicators of the building, depending on its thermal protection, was carried out. The methods were tested for buildings whose working day lasts from 9 am to 6 pm with various internal heat generation. In this case, it was believed that solar radiation is completely obscured. From consideration of the effect of heat gains on energy-efficient thermal protection, it was found that with increasing heat gains, the load on heating systems decreases regardless of the level of heat protection, and the load on the room cooling systems increases more with higher thermal protection than with low thermal protection. However, there are buildings of a number of functional purposes in which solar radiation is partially obscured or not obscured at all. These include some commercial, residential and other buildings. Accounting for heat gains from solar radiation, with variable intensity throughout the year, makes significant adjustments to the choice of the level of thermal protection. This is due to the fact that often cooling of the room is required during periods when the outside air temperature is below the maximum allowable temperature of the room. During these periods, enhanced thermal protection is an obstacle to the natural outflow of heat from the premises. Calculations showed that the higher the heat gain from solar radiation, the smaller the proportion of buildings it is energetically feasible to warm according to the basic standards stipulated in SP 50.13330.2012. And although it is not energetically feasible to carry out thermal insulation for sanitary and hygienic requirements, the conclusions about the benefits of building insulation with reduced heat transfer to the walls and coatings of a building are economically significant. It is also important that when identifying an economically feasible thermal protection of a building, it is necessary to take into account all the components of financial expenses that are affected by the thermal protection of a building. The calculations also showed that an increase in the cost of heat and electricity over time changes the thermal performance of buildings for which this or that thermal protection is economically feasible.


  • Open Access

    The Choice of Energy Efficient Thermal Protection of Office Buildings with Different Internal Heat Intake

    by E G Malyavina, A A Frolova

    The annual energy consumption of the building is greatly influenced by the internal heat intake to the premises. Under heating the incoming heat plays a positive role. During the working day, it compensates the heat losses partly or in full. As far as the cooling is concerned, the thermal emissions in the building play a negative role and the specific need for cold increases with the increase in the specific heat emissions. The aim of the study was to identify the dependence of the annual thermal consumption for heating, as well as the needs in cold for natural and artificial cooling of the building, from various factors, such as the shape of the building and its thermal protection. In annual terms, the load on natural and artificial cooling systems is less in the buildings with the lowest thermal protection and with smaller heat access into the room. It is also interesting, that the cooling load is less when the facade is more glazed, since the heat protection of the building is reducing, which only confirms the previous thesis (the heat access from the solar radiation is usually minimal, since the windows in the buildings with cooling are shaded). The smaller the building in volume is, the higher the heat the lowest energy consumption during the year is achieved with the greatest heat insulation. The ratio between the consumption of heat and cold during the year is also an important information, as the cooling of the building requires 3 to 4 times more primary fuel than heating.