Chromium speciation in the blood of metal-on-metal hip implant patients
- 28 March 2016
- journal article
- research article
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 99 (1) , 48-64
Abstract
The objective of this study was to determine the valence state of chromium (Cr) in the blood of individuals with Cr-containing metal hip implants. Serum and red blood cell (RBC) Cr concentrations from 52 patients with Cr-containing total hip arthroplasties were measured preoperatively and at 3, 12, and 24 months postoperatively. Geometric mean and median pre-surgery serum Cr concentrations were consistently below 0.2 µg/L, while geometric mean and median pre-op RBC Cr concentrations were typically about four- to six-fold higher than the serum values. A significant 5- to 13-fold increase was found in the mean and median serum Cr concentrations three months post-surgery, with an 8- to 18-fold rise at 12 and 24 months, respectively. Steady-state serum concentrations were reached between 3 and 12 months. In contrast, there were no marked differences in mean and median RBC Cr concentrations pre- and post-surgery. Slope regression analysis for our data was similar to those reported for Cr(III) in spiked blood samples. The analysis showed that Cr released from hip implants preferentially distributed into serum and not RBC, indicating that the form of Cr present in blood of hip implant patients was in the form of non-toxic Cr(III). Our findings indicate that blood Cr concentrations Cr(III) associated with metal implants do not pose an adverse health risk to patients, which is in agreement with findings published by most investigators.Keywords
Funding Information
- DePuy Orthopaedics, Inc.
This publication has 57 references indexed in Scilit:
- Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfacesBone & Joint Research, 2013
- Electrochemical control of cell death by reduction-induced intrinsic apoptosis and oxidation-induced necrosis on CoCrMo alloy in vitroBiomaterials, 2012
- Experimental Models of Abdominal Aortic AneurysmsThe Open Cardiovascular Medicine Journal, 2010
- The chemical form of metallic debris in tissues surrounding metal-on-metal hips with unexplained failureActa Biomaterialia, 2010
- Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacingsThe Journal of Bone and Joint Surgery. British volume, 2009
- 2008 John Charnley Award: Metal Ion Levels After Metal-on-Metal Total Hip Arthroplasty: A Randomized TrialClinical Orthopaedics and Related Research, 2009
- Human Ingestion of Chromium (VI) in Drinking Water: Pharmacokinetics Following Repeated ExposureToxicology and Applied Pharmacology, 1997
- INGESTION OF CHROMIUM(VI) IN DRINKING WATER BY HUMAN VOLUNTEERS: ABSORPTION, DISTRIBUTION, AND EXCRETION OF SINGLE AND REPEATED DOSESJournal of Toxicology and Environmental Health, 1997
- Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatmentInternational Journal of Oral and Maxillofacial Surgery, 1993
- A combined metallurgical and histological study of tissue‐prosthesis interactions in orthopedic patientsJournal of Biomedical Materials Research, 1974