Abstract
Conventional BOLD‐fMRI relies on hemodynamic responses that are temporally and spatially indirect markers of neural activity. Developing alternative contrasts, sensitive to neuroelectrical phenomena, is a critical challenge in brain imaging. Spin‐lock (SL) fMRI has shown promise in phantom studies for detecting magnetic field changes associated with neuronal activity, but its in‐vivo sensitivity and practicality remain unclear. This study evaluated whether SL contrast can effectively detect and localize human neuronal activation, benchmarked against complementary functional modalities, magnetoencephalography (MEG) and 3T BOLD‐fMRI, to assess the sensitivity of MR‐based neuronal current imaging. Thirteen healthy young volunteers underwent SL‐based imaging during 8 Hz visual stimulation, along with BOLD and MEG acquisitions. Subjects viewed quadrant‐checkerboard stimuli to elicit localized cortical responses. Two balanced SL contrast mechanisms, rotary excitation (REX) and stimulus‐induced rotary saturation (SIRS), were employed. Postprocessing targeted stimulus‐locked signal fluctuations using a regression‐filtering‐rectification strategy. Phantom experiments tested sensitivity and analysis pipeline performance. MEG revealed robust stimulus‐locked responses in the occipital cortex, with estimated local magnetic field amplitudes of ~0.07 nT. Conventional BOLD‐fMRI confirmed reliable hemodynamic activation. In contrast, neither balanced REX nor balanced SIRS produced consistent stimulus‐related activation in vivo. Phantom experiments subsequently yielded detection thresholds of 0.2 nT for REX and 0.6 nT for SIRS, exceeding the MEG‐estimated physiological field amplitudes. Under the present experimental conditions, the tested spin‐lock fMRI implementations did not achieve sufficient sensitivity for reliable in vivo detection of neuronal magnetic fields at 3T. Phantom and MEG‐based estimates indicate that physiological field amplitudes in the visual cortex lie below current detection limits. These findings establish quantitative constraints on direct neuronal current imaging with MRI and provide a benchmark for future methodological developments aimed at bridging electrophysiology and functional MRI.Keywords
Funding Information
- International Society for Magnetic Resonance in Medicine (Research Exchange Grant 2022)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (CRSII5‐180365)
This publication has 25 references indexed in Scilit:
- Stimulus‐induced rotary saturation imaging of visually evoked response: A pilot studyNMR in Biomedicine, 2024
- Amplitude of high frequency oscillations as a biomarker of the seizure onset zoneClinical Neurophysiology, 2020
- Toward direct MRI of neuro‐electro‐magnetic oscillations in the human brainMagnetic Resonance in Medicine, 2019
- Looking for neuronal currents using MRI: An EEG-fMRI investigation of fast MR signal changes time-locked to frequent focal epileptic dischargesNeuroImage, 2010
- Stimulus-induced Rotary Saturation (SIRS): A potential method for the detection of neuronal currents with MRINeuroImage, 2008
- Realistic simulations of neuronal activity: A contribution to the debate on direct detection of neuronal currents by MRINeuroImage, 2008
- Artifacts in T1ρ-weighted imaging: Compensation for B1 and B0 field imperfectionsJournal of Magnetic Resonance, 2007
- Inability to directly detect magnetic field changes associated with neuronal activityMagnetic Resonance in Medicine, 2007
- Hunting for neuronal currents: absence of rapid MRI signal changes during visual-evoked responseNeuroImage, 2004
- Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changesMagnetic Resonance in Medicine, 2002