Milena Capiglioni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Milena Capiglioni has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Federico Turco
Support Center for Advanced Neuroimaging (SCAN), Inselspital Institute for Diagnostic and Interventional Neuroradiology Bern Bern Switzerland
5 shared publications - Roland Wiest
Support Center for Advanced Neuroimaging (SCAN), University Institute of Diagnostic and Interventional Neuroradiology, University Hospital Bern, Switzerland
4 shared publications - Johannes Slotboom
Support Center for Advanced Neuroimaging, University Institute of Diagnostic and Interventional Neuroradiology, University Hospital Bern, Inselspital, University of Bern, Bern, Switzerland
3 shared publications Roland Wiest
Institute for Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern , 3010 Bern
3 shared publications- Christian Rummel
Support Center for Advanced Neuroimaging (SCAN), University Institute of Diagnostic and Interventional Neuroradiology University of Bern, Inselspital, Bern University Hospital Bern Switzerland
2 shared publications - Davide Tabarelli
Center for Mind and Brain Sciences (CIMeC) University of Trento Rovereto Italy
2 shared publications
Latest Publications
- Open Access
- 7 August 2026
- Published by Wiley in Human Brain Mapping
- Vol. 47 (11)
Exploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain
Conventional BOLD‐fMRI relies on hemodynamic responses that are temporally and spatially indirect markers of neural activity. Developing alternative contrasts, sensitive to neuroelectrical phenomena, is a critical challenge in brain imaging. Spin‐lock (SL) fMRI has shown promise in phantom studies for detecting magnetic field changes associated with neuronal activity, but its in‐vivo sensitivity and practicality remain unclear. This study evaluated whether SL contrast can effectively detect and localize human neuronal activation, benchmarked against complementary functional modalities, magnetoencephalography (MEG) and 3T BOLD‐fMRI, to assess the sensitivity of MR‐based neuronal current imaging. Thirteen healthy young volunteers underwent SL‐based imaging during 8 Hz visual stimulation, along with BOLD and MEG acquisitions. Subjects viewed quadrant‐checkerboard stimuli to elicit localized cortical responses. Two balanced SL contrast mechanisms, rotary excitation (REX) and stimulus‐induced rotary saturation (SIRS), were employed. Postprocessing targeted stimulus‐locked signal fluctuations using a regression‐filtering‐rectification strategy. Phantom experiments tested sensitivity and analysis pipeline performance. MEG revealed robust stimulus‐locked responses in the occipital cortex, with estimated local magnetic field amplitudes of ~0.07 nT. Conventional BOLD‐fMRI confirmed reliable hemodynamic activation. In contrast, neither balanced REX nor balanced SIRS produced consistent stimulus‐related activation in vivo. Phantom experiments subsequently yielded detection thresholds of 0.2 nT for REX and 0.6 nT for SIRS, exceeding the MEG‐estimated physiological field amplitudes. Under the present experimental conditions, the tested spin‐lock fMRI implementations did not achieve sufficient sensitivity for reliable in vivo detection of neuronal magnetic fields at 3T. Phantom and MEG‐based estimates indicate that physiological field amplitudes in the visual cortex lie below current detection limits. These findings establish quantitative constraints on direct neuronal current imaging with MRI and provide a benchmark for future methodological developments aimed at bridging electrophysiology and functional MRI.
- 7 August 2026
- Published by Wiley in Human Brain Mapping
- Vol. 47 (11)
Open AccessExploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain
Conventional BOLD‐fMRI relies on hemodynamic responses that are temporally and spatially indirect markers of neural activity. Developing alternative contrasts, sensitive to neuroelectrical phenomena, is a critical challenge in brain imaging. Spin‐lock (SL) fMRI has shown promise in phantom studies for detecting magnetic field changes associated with neuronal activity, but its in‐vivo sensitivity and practicality remain unclear. This study evaluated whether SL contrast can effectively detect and localize human neuronal activation, benchmarked against complementary functional modalities, magnetoencephalography (MEG) and 3T BOLD‐fMRI, to assess the sensitivity of MR‐based neuronal current imaging. Thirteen healthy young volunteers underwent SL‐based imaging during 8 Hz visual stimulation, along with BOLD and MEG acquisitions. Subjects viewed quadrant‐checkerboard stimuli to elicit localized cortical responses. Two balanced SL contrast mechanisms, rotary excitation (REX) and stimulus‐induced rotary saturation (SIRS), were employed. Postprocessing targeted stimulus‐locked signal fluctuations using a regression‐filtering‐rectification strategy. Phantom experiments tested sensitivity and analysis pipeline performance. MEG revealed robust stimulus‐locked responses in the occipital cortex, with estimated local magnetic field amplitudes of ~0.07 nT. Conventional BOLD‐fMRI confirmed reliable hemodynamic activation. In contrast, neither balanced REX nor balanced SIRS produced consistent stimulus‐related activation in vivo. Phantom experiments subsequently yielded detection thresholds of 0.2 nT for REX and 0.6 nT for SIRS, exceeding the MEG‐estimated physiological field amplitudes. Under the present experimental conditions, the tested spin‐lock fMRI implementations did not achieve sufficient sensitivity for reliable in vivo detection of neuronal magnetic fields at 3T. Phantom and MEG‐based estimates indicate that physiological field amplitudes in the visual cortex lie below current detection limits. These findings establish quantitative constraints on direct neuronal current imaging with MRI and provide a benchmark for future methodological developments aimed at bridging electrophysiology and functional MRI.
- Open Access
- 30 June 2026
- Published by Oxford University Press (OUP) in Brain Communications
- Vol. 8 (4)
Field strength–dependent sensitivity of chemical exchange saturation transfer: a methodological comparison of 3 Tesla and 7 Tesla in a clinical cohort
Chemical exchange saturation transfer (CEST) MRI provides insight into tissue metabolism by detecting low-concentration endogenous molecules. While studies at 7 Tesla (7T) have shown enhanced sensitivity and spectral separation, 3 Tesla (3T) remains the clinical standard, and the relative performance of these field strengths in a direct clinical head-to-head comparison remains unclear. This prospective cohort study provides a direct within-subject comparison of multi-pool CEST imaging at 3T and 7T, using age-related tissue changes and glioma molecular subtypes as representative applications of physiological and pathological CEST sensitivity. Forty-three patients (ages 18–76; 18 female) underwent 3T and 7T CEST MRI prior to surgery due to suspected brain tumour; following quality control, 36 datasets were included at 3T and 32 at 7T. CEST amplitudes from amide, amine, aliphatic relayed nuclear Overhauser effect (rNOE) and magnetization transfer pools were quantified in white matter, grey matter, deep grey matter and tumour tissue. A physics-informed conditional autoencoder (PICAE) was applied at 7T to correct B1 inhomogeneity. Age effects were tested using linear regression; tumour subtype differences were tested using the Wilcoxon rank-sum test. The significance level was set to α = 0.05, and the Holm–Bonferroni procedure was applied to correct for multiple testing. At 7T, amide and rNOE showed robust negative correlations with age in grey matter and deep grey matter, supporting the potential of CEST as an ageing biomarker. Age dependence at 3T was weaker, limited to rNOE (grey matter and deep grey matter) and magnetization transfer (white matter and deep grey matter). In contrast, tumour CEST metrics showed no significant age dependence at either field strength. Trends in relative amide contrast were consistent with prior findings but did not reach statistical significance. Sensitivity to tumour molecular subtype was similar across field strengths. Variability analyses showed that conventional 7T processing introduced higher technical variability than 3T, whereas PICAE substantially reduced variability and improved data quality at 7T. In conclusion, 7T CEST MRI demonstrates higher potential as a non-invasive marker of brain ageing, whereas our simplified pipeline did not yield additional information for tumour subtyping at either field strength. These findings underscore both the enhanced sensitivity and the higher technical demands of 7T, and highlight the importance of advanced correction strategies such as PICAE for robust use of single-transmit 7T CEST.
- 30 June 2026
- Published by Oxford University Press (OUP) in Brain Communications
- Vol. 8 (4)
Open AccessField strength–dependent sensitivity of chemical exchange saturation transfer: a methodological comparison of 3 Tesla and 7 Tesla in a clinical cohort
Chemical exchange saturation transfer (CEST) MRI provides insight into tissue metabolism by detecting low-concentration endogenous molecules. While studies at 7 Tesla (7T) have shown enhanced sensitivity and spectral separation, 3 Tesla (3T) remains the clinical standard, and the relative performance of these field strengths in a direct clinical head-to-head comparison remains unclear. This prospective cohort study provides a direct within-subject comparison of multi-pool CEST imaging at 3T and 7T, using age-related tissue changes and glioma molecular subtypes as representative applications of physiological and pathological CEST sensitivity. Forty-three patients (ages 18–76; 18 female) underwent 3T and 7T CEST MRI prior to surgery due to suspected brain tumour; following quality control, 36 datasets were included at 3T and 32 at 7T. CEST amplitudes from amide, amine, aliphatic relayed nuclear Overhauser effect (rNOE) and magnetization transfer pools were quantified in white matter, grey matter, deep grey matter and tumour tissue. A physics-informed conditional autoencoder (PICAE) was applied at 7T to correct B1 inhomogeneity. Age effects were tested using linear regression; tumour subtype differences were tested using the Wilcoxon rank-sum test. The significance level was set to α = 0.05, and the Holm–Bonferroni procedure was applied to correct for multiple testing. At 7T, amide and rNOE showed robust negative correlations with age in grey matter and deep grey matter, supporting the potential of CEST as an ageing biomarker. Age dependence at 3T was weaker, limited to rNOE (grey matter and deep grey matter) and magnetization transfer (white matter and deep grey matter). In contrast, tumour CEST metrics showed no significant age dependence at either field strength. Trends in relative amide contrast were consistent with prior findings but did not reach statistical significance. Sensitivity to tumour molecular subtype was similar across field strengths. Variability analyses showed that conventional 7T processing introduced higher technical variability than 3T, whereas PICAE substantially reduced variability and improved data quality at 7T. In conclusion, 7T CEST MRI demonstrates higher potential as a non-invasive marker of brain ageing, whereas our simplified pipeline did not yield additional information for tumour subtyping at either field strength. These findings underscore both the enhanced sensitivity and the higher technical demands of 7T, and highlight the importance of advanced correction strategies such as PICAE for robust use of single-transmit 7T CEST.
- Open Access
- 1 June 2026
- Published by Wiley in Human Brain Mapping
- Vol. 47 (8) , e70560
Mitigating the Impact of MR Sequence Parameters: Increasing the Robustness of DL‐Based Cortical Thickness Estimates
Cortical thickness measurements from MRI are increasingly used as biomarkers for neurodegenerative disease progression. However, variations in MRI acquisition parameters, such as inversion time (TI) and repetition time (TR), which are common in clinical settings, can compromise the reliability and sensitivity of these measurements. We fine-tuned a deep-learning-based segmentation tool (DL+DiReCT) to reduce its dependence to image contrast variations by training it on simulated MPRAGE images derived from quantitative relaxation maps. Fine-tuning markedly reduced contrast sensitivity, with the Pearson correlation coefficient decreasing from to . Evaluation on a synthetic atrophy dataset demonstrated that our model accurately replicated atrophy trends with minimal underestimation, outperforming FreeSurfer and SynthSeg. When applied to a dataset of relapsing–remitting multiple sclerosis (RRMS) patients, the fine-tuned model showed a substantial reduction in contrast sensitivity and maintained stable performance after controlling for covariates such as age, sex, field strength, and Expanded Disability Status Scale (EDSS) score. Overall, the proposed approach achieves robust contrast invariance without sacrificing sensitivity to cortical atrophy, offering a practical improvement for longitudinal and multi-center clinical studies.- 1 June 2026
- Published by Wiley in Human Brain Mapping
- Vol. 47 (8) , e70560
Open AccessMitigating the Impact of MR Sequence Parameters: Increasing the Robustness of DL‐Based Cortical Thickness Estimates
Cortical thickness measurements from MRI are increasingly used as biomarkers for neurodegenerative disease progression. However, variations in MRI acquisition parameters, such as inversion time (TI) and repetition time (TR), which are common in clinical settings, can compromise the reliability and sensitivity of these measurements. We fine-tuned a deep-learning-based segmentation tool (DL+DiReCT) to reduce its dependence to image contrast variations by training it on simulated MPRAGE images derived from quantitative relaxation maps. Fine-tuning markedly reduced contrast sensitivity, with the Pearson correlation coefficient decreasing from to . Evaluation on a synthetic atrophy dataset demonstrated that our model accurately replicated atrophy trends with minimal underestimation, outperforming FreeSurfer and SynthSeg. When applied to a dataset of relapsing–remitting multiple sclerosis (RRMS) patients, the fine-tuned model showed a substantial reduction in contrast sensitivity and maintained stable performance after controlling for covariates such as age, sex, field strength, and Expanded Disability Status Scale (EDSS) score. Overall, the proposed approach achieves robust contrast invariance without sacrificing sensitivity to cortical atrophy, offering a practical improvement for longitudinal and multi-center clinical studies. - Open Access
Exploring the sensitivity limits of neuronal current imaging with MRI and MEG in the human brain
Introduction: Conventional BOLD-fMRI relies on hemodynamic responses that are temporally and spatially indirect markers of neural activity. Developing alternative contrasts, sensitive to neuroelectrical phenomena, is a critical challenge in brain imaging. Spin-lock (SL) fMRI has shown promise in phantom studies for detecting magnetic field changes associated with neuronal activity, but its in-vivo sensitivity and practicality remain unclear. This study evaluated whether SL contrast can effectively detect and localize human neuronal activation, benchmarked against complementary functional modalities, magnetoencephalography (MEG) and 3T BOLD-fMRI, to assess the sensitivity of MR-based neuronal current imaging. Methods: Thirteen healthy young volunteers underwent SL-based imaging during 8 Hz visual stimulation, along with BOLD and MEG acquisitions. Subjects viewed quadrant-checkerboard stimuli to elicit localized cortical responses. Two balanced SL contrast mechanisms, rotary excitation (REX) and stimulus-induced rotary saturation (SIRS), were employed. Postprocessing targeted stimulus-locked signal fluctuations using a regression-filtering-rectification strategy. Phantom experiments tested sensitivity and analysis pipeline performance. Results: MEG revealed robust stimulus-locked responses in occipital cortex, with estimated local magnetic field amplitudes of ∼0.07 nT. Conventional BOLD-fMRI confirmed reliable hemodynamic activation. In contrast, neither balanced REX nor balanced SIRS produced consistent stimulus-related activation in vivo. Phantom experiments subsequently yielded detection thresholds of 0.2 nT for REX and 0.6 nT for SIRS, exceeding the MEG-estimated physiological field amplitudes. Conclusions: Under the present experimental conditions, the tested spin-lock fMRI implementations did not achieve sufficient sensitivity for reliable in-vivo detection of neuronal magnetic fields at 3T. Phantom and MEG-based estimates indicate that physiological field amplitudes in the visual cortex lie below current detection limits. These findings establish quantitative constraints on direct neuronal current imaging with MRI and provide a benchmark for future methodological developments aimed at bridging electrophysiology and functional MRI. Key points: We assessed spin-lock fMRI sensitivity using combined SL-fMRI, BOLD-fMRI, MEG, and phantom measurements during visual stimulation. MEG and BOLD-fMRI confirmed robust neuronal and hemodynamic activation in the visual cortex. SL-fMRI did not achieve reliable in-vivo detection of neuronal magnetic fields; phantom sensitivity limits exceeded MEG-estimated physiological field amplitudes.
Open AccessExploring the sensitivity limits of neuronal current imaging with MRI and MEG in the human brain
Introduction: Conventional BOLD-fMRI relies on hemodynamic responses that are temporally and spatially indirect markers of neural activity. Developing alternative contrasts, sensitive to neuroelectrical phenomena, is a critical challenge in brain imaging. Spin-lock (SL) fMRI has shown promise in phantom studies for detecting magnetic field changes associated with neuronal activity, but its in-vivo sensitivity and practicality remain unclear. This study evaluated whether SL contrast can effectively detect and localize human neuronal activation, benchmarked against complementary functional modalities, magnetoencephalography (MEG) and 3T BOLD-fMRI, to assess the sensitivity of MR-based neuronal current imaging. Methods: Thirteen healthy young volunteers underwent SL-based imaging during 8 Hz visual stimulation, along with BOLD and MEG acquisitions. Subjects viewed quadrant-checkerboard stimuli to elicit localized cortical responses. Two balanced SL contrast mechanisms, rotary excitation (REX) and stimulus-induced rotary saturation (SIRS), were employed. Postprocessing targeted stimulus-locked signal fluctuations using a regression-filtering-rectification strategy. Phantom experiments tested sensitivity and analysis pipeline performance. Results: MEG revealed robust stimulus-locked responses in occipital cortex, with estimated local magnetic field amplitudes of ∼0.07 nT. Conventional BOLD-fMRI confirmed reliable hemodynamic activation. In contrast, neither balanced REX nor balanced SIRS produced consistent stimulus-related activation in vivo. Phantom experiments subsequently yielded detection thresholds of 0.2 nT for REX and 0.6 nT for SIRS, exceeding the MEG-estimated physiological field amplitudes. Conclusions: Under the present experimental conditions, the tested spin-lock fMRI implementations did not achieve sufficient sensitivity for reliable in-vivo detection of neuronal magnetic fields at 3T. Phantom and MEG-based estimates indicate that physiological field amplitudes in the visual cortex lie below current detection limits. These findings establish quantitative constraints on direct neuronal current imaging with MRI and provide a benchmark for future methodological developments aimed at bridging electrophysiology and functional MRI. Key points: We assessed spin-lock fMRI sensitivity using combined SL-fMRI, BOLD-fMRI, MEG, and phantom measurements during visual stimulation. MEG and BOLD-fMRI confirmed robust neuronal and hemodynamic activation in the visual cortex. SL-fMRI did not achieve reliable in-vivo detection of neuronal magnetic fields; phantom sensitivity limits exceeded MEG-estimated physiological field amplitudes.
- Open Access
- 2 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (1) , 38-50
Accelerated water residual removal in MRS : Exploring deep learning versus fitting‐based approaches
Purpose: Removing water residual signals from MRS spectra is crucial for accurate metabolite quantification. However, currently available algorithms are computationally intensive and time‐consuming, limiting their clinical applicability. This work aims to propose and validate two novel pipelines for fast water residual removal in MRS. Methods: Two methods for water residual removal are proposed and evaluated: DeepWatR and WaterFit. DeepWatR uses a U‐Net‐like architecture with an attention mechanism for skip connections. WaterFit uses Torch auto‐differentiation to estimate parameters for a 7‐pool Lorentzian model. The accuracy and time‐efficiency of these methods were assessed using simulated and in vivo 1H brain datasets and compared with the gold standard, Hankel Lanczos singular value decomposition method (HLSVD)Pro. Results: In the simulated dataset, the average percentage quantification error was % for DeepWatR and % for WaterFit, both comparable to % for HLSVDPro in the main metabolites (Cr, Cho, and NAA). DeepWatR was 51 times faster and WaterFit was 22.7 times faster than HLSVDPro for a dataset of 10 000 voxels when using a low‐end graphics processing unit. For 100 voxels, the speed‐up is 6.5 and 7.5 times faster for DeepWatR and WaterFit, respectively. WaterFit showed higher metabolite fitting accuracy after water removal compared to DeepWatR. Conclusion: WaterFit showed a superior balance of accuracy and processing speed in removing water residual from MRS data compared to DeepWatR. The proposed WaterFit implementation significantly reduces preprocessing time while maintaining metabolite fitting accuracy comparable to gold standard methods. This advancement addresses the need for efficient processing methods that can facilitate analysis and enhance the clinical utility of MRS.
- 2 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (1) , 38-50
Open AccessAccelerated water residual removal in MRS : Exploring deep learning versus fitting‐based approaches
Purpose: Removing water residual signals from MRS spectra is crucial for accurate metabolite quantification. However, currently available algorithms are computationally intensive and time‐consuming, limiting their clinical applicability. This work aims to propose and validate two novel pipelines for fast water residual removal in MRS. Methods: Two methods for water residual removal are proposed and evaluated: DeepWatR and WaterFit. DeepWatR uses a U‐Net‐like architecture with an attention mechanism for skip connections. WaterFit uses Torch auto‐differentiation to estimate parameters for a 7‐pool Lorentzian model. The accuracy and time‐efficiency of these methods were assessed using simulated and in vivo 1H brain datasets and compared with the gold standard, Hankel Lanczos singular value decomposition method (HLSVD)Pro. Results: In the simulated dataset, the average percentage quantification error was % for DeepWatR and % for WaterFit, both comparable to % for HLSVDPro in the main metabolites (Cr, Cho, and NAA). DeepWatR was 51 times faster and WaterFit was 22.7 times faster than HLSVDPro for a dataset of 10 000 voxels when using a low‐end graphics processing unit. For 100 voxels, the speed‐up is 6.5 and 7.5 times faster for DeepWatR and WaterFit, respectively. WaterFit showed higher metabolite fitting accuracy after water removal compared to DeepWatR. Conclusion: WaterFit showed a superior balance of accuracy and processing speed in removing water residual from MRS data compared to DeepWatR. The proposed WaterFit implementation significantly reduces preprocessing time while maintaining metabolite fitting accuracy comparable to gold standard methods. This advancement addresses the need for efficient processing methods that can facilitate analysis and enhance the clinical utility of MRS.
- Open Access
- 4 November 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (1) , e5280
Stimulus‐induced rotary saturation imaging of visually evoked response: A pilot study
Spin‐lock (SL) pulses have been proposed to directly detect neuronal activity otherwise inaccessible through standard functional magnetic resonance imaging. However, the practical limits of this technique remain unexplored. Key challenges in SL‐based detection include ultra‐weak signal variations, sensitivity to magnetic field inhomogeneities, and potential contamination from blood oxygen level‐dependent effects, all of which hinder the reliable isolation of neuronal signals. This pilot study evaluates the performance of the stimulus‐induced rotary saturation (SIRS) technique to map visual stimulation response in the human cortex. A rotary echo spin‐lock (RESL) preparation followed by a 2D echo planar imaging readout was used to investigate 12 healthy subjects at rest and during continuous exposure to 8 Hz flickering light. The SL amplitude was fixed to the target neuroelectric oscillations at that frequency. The signal variance was used as contrast metric, and two alternative post‐processing pipelines (regression‐filtering‐rectification and normalized subtraction) were statistically evaluated. Higher variance in the SL signal was detected in four of the 12 subjects. Although group‐level analysis indicated activation in the occipital pole, analysis of variance revealed that this difference was not statistically significant, highlighting the need for comparable control measures and more robust preparations. Further optimization in sensitivity and robustness is required to noninvasively detect physiological neuroelectric activity in the human brain.
- 4 November 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (1) , e5280
Open AccessStimulus‐induced rotary saturation imaging of visually evoked response: A pilot study
Spin‐lock (SL) pulses have been proposed to directly detect neuronal activity otherwise inaccessible through standard functional magnetic resonance imaging. However, the practical limits of this technique remain unexplored. Key challenges in SL‐based detection include ultra‐weak signal variations, sensitivity to magnetic field inhomogeneities, and potential contamination from blood oxygen level‐dependent effects, all of which hinder the reliable isolation of neuronal signals. This pilot study evaluates the performance of the stimulus‐induced rotary saturation (SIRS) technique to map visual stimulation response in the human cortex. A rotary echo spin‐lock (RESL) preparation followed by a 2D echo planar imaging readout was used to investigate 12 healthy subjects at rest and during continuous exposure to 8 Hz flickering light. The SL amplitude was fixed to the target neuroelectric oscillations at that frequency. The signal variance was used as contrast metric, and two alternative post‐processing pipelines (regression‐filtering‐rectification and normalized subtraction) were statistically evaluated. Higher variance in the SL signal was detected in four of the 12 subjects. Although group‐level analysis indicated activation in the occipital pole, analysis of variance revealed that this difference was not statistically significant, highlighting the need for comparable control measures and more robust preparations. Further optimization in sensitivity and robustness is required to noninvasively detect physiological neuroelectric activity in the human brain.
- Open Access
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 447-458
TensorFit: A torch‐based tool for ultrafast metabolite fitting of large MRSI data sets
Purpose: To introduce a tool (TensorFit) for ultrafast and robust metabolite fitting of MRSI data based on Torch's auto‐differentiation and optimization framework.Methods: TensorFit was implemented in Python based on Torch's auto‐differentiation to fit individual metabolites in MRS spectra. The underlying time domain and/or frequency domain fitting model is based on a linear combination of metabolite spectroscopic response. The computational time efficiency and accuracy of TensorFit were tested on simulated and in vivo MRS data and compared against TDFDFit and QUEST.Results: TensorFit demonstrates a significant improvement in computation speed, achieving a 165‐times acceleration compared with TDFDFit and 115 times against QUEST. TensorFit showed smaller percentual errors on simulated data compared with TDFDFit and QUEST. When tested on in vivo data, it performed similarly to TDFDFit with a 2% better fit in terms of mean squared error while obtaining a 169‐fold speedup.Conclusion: TensorFit enables fast and robust metabolite fitting in large MRSI data sets compared with conventional metabolite fitting methods. This tool could boost the clinical applicability of large 3D MRSI by enabling the fitting of large MRSI data sets within computation times acceptable in a clinical environment.
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 447-458
Open AccessTensorFit: A torch‐based tool for ultrafast metabolite fitting of large MRSI data sets
Purpose: To introduce a tool (TensorFit) for ultrafast and robust metabolite fitting of MRSI data based on Torch's auto‐differentiation and optimization framework.Methods: TensorFit was implemented in Python based on Torch's auto‐differentiation to fit individual metabolites in MRS spectra. The underlying time domain and/or frequency domain fitting model is based on a linear combination of metabolite spectroscopic response. The computational time efficiency and accuracy of TensorFit were tested on simulated and in vivo MRS data and compared against TDFDFit and QUEST.Results: TensorFit demonstrates a significant improvement in computation speed, achieving a 165‐times acceleration compared with TDFDFit and 115 times against QUEST. TensorFit showed smaller percentual errors on simulated data compared with TDFDFit and QUEST. When tested on in vivo data, it performed similarly to TDFDFit with a 2% better fit in terms of mean squared error while obtaining a 169‐fold speedup.Conclusion: TensorFit enables fast and robust metabolite fitting in large MRSI data sets compared with conventional metabolite fitting methods. This tool could boost the clinical applicability of large 3D MRSI by enabling the fitting of large MRSI data sets within computation times acceptable in a clinical environment.
- Open Access
- 26 April 2023
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 51 (1) , 5-9
Growing importance of brain morphometry analysis in the clinical routine: The hidden impact of MR sequence parameters
- 26 April 2023
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 51 (1) , 5-9
Open AccessGrowing importance of brain morphometry analysis in the clinical routine: The hidden impact of MR sequence parameters
- Open Access
Analysis of the robustness and dynamics of spin-locking preparations for the detection of oscillatory magnetic fields
Extracting quantitative information of neuronal signals by non-invasive imaging is an outstanding challenge for understanding brain function and pathology. However, state-of-the-art techniques offer low sensitivity to deep electrical sources. Stimulus induced rotary saturation (SIRS) is a recently proposed magnetic resonance imaging (MRI) sequence that detects oscillatory magnetic fields using a spin-lock preparation. Phantom experiments and simulations proved its efficiency and sensitivity, but the susceptibility of the method to field inhomogeneities is still not well understood. In this study, we simulated and analyzed the dynamic of three spin-lock preparations and their response to field inhomogeneities in the presence of a resonant oscillating field. We show that the composite spin-lock preparation is more robust against field variations within the double resonance effect. In addition, we tested the capability of the chosen composite spin-lock preparation to recover information about the spectral components of a composite signal. This study sets the bases to move one step further towards the clinical application of MR-based neuronal current imaging.
Open AccessAnalysis of the robustness and dynamics of spin-locking preparations for the detection of oscillatory magnetic fields
Extracting quantitative information of neuronal signals by non-invasive imaging is an outstanding challenge for understanding brain function and pathology. However, state-of-the-art techniques offer low sensitivity to deep electrical sources. Stimulus induced rotary saturation (SIRS) is a recently proposed magnetic resonance imaging (MRI) sequence that detects oscillatory magnetic fields using a spin-lock preparation. Phantom experiments and simulations proved its efficiency and sensitivity, but the susceptibility of the method to field inhomogeneities is still not well understood. In this study, we simulated and analyzed the dynamic of three spin-lock preparations and their response to field inhomogeneities in the presence of a resonant oscillating field. We show that the composite spin-lock preparation is more robust against field variations within the double resonance effect. In addition, we tested the capability of the chosen composite spin-lock preparation to recover information about the spectral components of a composite signal. This study sets the bases to move one step further towards the clinical application of MR-based neuronal current imaging.
- 25 January 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (1) , 014045
Noninvasive Quantitative Imaging of Selective Microstructure Sizes via Magnetic Resonance
Extracting quantitative microstructure information of living tissue by noninvasive imaging is an outstanding challenge for understanding disease mechanisms and allowing early stage diagnosis of pathologies. Magnetic resonance imaging (MRI) is a promising and widely used technique to pursue this goal, but still provides low resolution to reveal microstructure details. We here report on a method to produce images of filtered microstructure sizes based on selectively probing the nuclear-spin dephasing induced by the molecular diffusion within specific tissue compartments. The microstructure-size filter relies on suitable dynamical control of nuclear spins that sense magnetization “decay shifts” rather than the commonly used spin-echo decay rates. The feasibility and performance of the method are illustrated with proof-of-principle experiments and simulations on typical size distributions of white matter in the mouse brain. These results position spin-echo decay shifts as a promising MRI tool as they could offer the ability to perform noninvasive histology without assuming a microstructure distribution model. This sets a step towards unraveling diagnostic information based on microscopic parameters of biological tissue.
- 25 January 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (1) , 014045
Noninvasive Quantitative Imaging of Selective Microstructure Sizes via Magnetic Resonance
Extracting quantitative microstructure information of living tissue by noninvasive imaging is an outstanding challenge for understanding disease mechanisms and allowing early stage diagnosis of pathologies. Magnetic resonance imaging (MRI) is a promising and widely used technique to pursue this goal, but still provides low resolution to reveal microstructure details. We here report on a method to produce images of filtered microstructure sizes based on selectively probing the nuclear-spin dephasing induced by the molecular diffusion within specific tissue compartments. The microstructure-size filter relies on suitable dynamical control of nuclear spins that sense magnetization “decay shifts” rather than the commonly used spin-echo decay rates. The feasibility and performance of the method are illustrated with proof-of-principle experiments and simulations on typical size distributions of white matter in the mouse brain. These results position spin-echo decay shifts as a promising MRI tool as they could offer the ability to perform noninvasive histology without assuming a microstructure distribution model. This sets a step towards unraveling diagnostic information based on microscopic parameters of biological tissue.