First clinical experience with the new Surpass Evolve flow diverter: technical and clinical considerations
- 12 February 2020
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 12 (10) , 974-980
Abstract
Objective To describe the results in patients treated with the Surpass Evolve (SE) device, the new generation of Surpass flow diverters. Methods Twenty-five consecutive patients (20 women, average age 58 years), with anterior or posterior circulation aneurysms treated with SEs in two early-user centers, were included. Device properties and related technical properties, imaging and clinical follow-up data, and intraprocedural, early (30 days) neurological complications, further divided into minor (silent/non-permanent) and major (permanent) complications, were recorded and analyzed. Results Twenty-nine SEs were successfully implanted in all subjects to treat 26 aneurysms using an 0.027" microcatheter with an average of 1.2 stents per patient. No intraprocedural thromboembolic or hemorrhagic complications were seen. At clinical follow-up, 24/25 (96%) patients had a modified Rankin Score of 0–2. Mortality was 0%. Imaging follow-up, available in 22/25 (88%) patients (median follow-up time 4 months), showed a complete aneurysm occlusion in 13/23 (57%) imaged lesions. Minor, transitory neurological deficits were recorded in 5/25 (20%) patients. One (4%) major complication was seen in one patient (4%) with a left-sided hemispheric stroke on postprocedural day 4 due to an acute stent thrombosis. Conclusions Preliminary experience in patients demonstrates a good performance of the SE. This newly designed implant maintains the engineering characteristics of Surpass flow diverters, including precise placement due to its lower foreshortening and a high mesh density, yet can be deployed through a significantly lower-profile delivery system.Keywords
This publication has 20 references indexed in Scilit:
- Treatment of anterior cerebral artery and anterior communicating artery aneurysms with flow-diversion devices: a systematic review and meta-analysisJournal of Neurosurgical Sciences, 2020
- Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year resultsJournal of NeuroInterventional Surgery, 2019
- SCENT TrialStroke, 2019
- Flow diversion for treatment of intracranial aneurysms: Mechanism and implicationsAnnals of Neurology, 2019
- Flow-diverter Stents for Internal Carotid Artery Reconstruction Following Spontaneous Dissection: A Technical ReportClinical Neuroradiology, 2018
- Safety and Efficacy of Flow Diverter Treatment for Aneurysm in Small Cerebral Vessels: A Systematic Review and Meta-AnalysisWorld Neurosurgery, 2018
- Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)Interventional Neurology, 2016
- Blood blister-like aneurysms: Single center experience and systematic literature reviewEuropean Journal of Radiology, 2014
- New Generation of Flow Diverter (Surpass) for Unruptured Intracranial AneurysmsStroke, 2013
- Flow-Diverting Stent for Ruptured Intracranial Dissecting Aneurysm of Vertebral ArteryNeurosurgery, 2012