Extraction of Cu, Fe, Mn, and Ni from Margarine Samples Using Extraction Induced by Emulsion Breaking Procedure Prior to Graphite Furnace Atomic Absorption Spectrometry and Comparison of Results to Provisional Tolerable Daily Intake Values
- 28 February 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 103 (5) , 1256-1263
Abstract
Background: The emulsion induced by emulsion breaking (EIEB) procedure was previously reported for the extraction of copper, iron, manganese, and nickel from liquid oil samples such as vegetable oil. Objective: To optimize the EIEB procedure for determination of copper, iron, manganese, and nickel in solid oil (margarine) samples by Graphite Furnace Atomic Absorption Spectrometry (GFAAS). Methods: The extraction procedure uses a surfactant in nitric acid to form an emulsion followed by heating to break the emulsion. Optimization included variation of the test portion size, the type and concentration of the surfactant, the concentration of nitric acid in the aqueous solution, the emulsion agitation time, heating temperature, and the time required to break the emulsion. Results: Mean element concentrations of 11 margarine samples were in the following ranges: Cu 0.031–0.131 µg/g, Fe 5.7–24.9 µg/g, Mn 0.542–1.11 µg/g, and Ni 0.108–0.134 µg/g. Under the optimized extraction conditions, the detection limits (µg/kg) were 4.8, 13, 1.5, and 23 for Cu, Fe, Mn, and Ni, respectively. The accuracy of the extraction procedure was determined by comparison to commonly used microwave digestion procedure. The EIEB results were not statistically different from the microwave digestion results when analyzed by GFAAS as determined by the statistical tests. Conclusions: The EIEB procedure was shown to be equivalent to the commonly used microwave digestion procedure for extraction of analytes from margarine samples. Highlights: The optimized EIEB extraction procedure is simple, rapid, low cost, and environmentally friendly. It has improved detection limits and allows calibration with aqueous standards.Keywords
This publication has 38 references indexed in Scilit:
- Strontium, silver, tin, iron, tellurium, gallium, germanium, barium and vanadium levels in foodstuffs from the Second French Total Diet StudyJournal of Food Composition and Analysis, 2012
- Emulsion liquid membrane for heavy metal removal: An overview on emulsion stabilization and destabilizationChemical Engineering Journal, 2011
- Flame and graphite furnace atomic absorption spectrometry for trace element determination in vegetable oils, margarine and butter after sample emulsificationFood Additives & Contaminants: Part A, 2011
- Extraction induced by emulsion breaking: a novel strategy for the trace metals determination in diesel oil samples by electrothermal atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 2010
- Investigation of the levels of some element in edible oil samples produced in Turkey by atomic absorption spectrometryJournal of Hazardous Materials, 2009
- The trace metal levels in milk and dairy products consumed in middle Anatolia—TurkeyEnvironmental Monitoring and Assessment, 2008
- Trace metal contents in chewing gums and candies marketed in TurkeyEnvironmental Monitoring and Assessment, 2008
- Rapid determination of some trace metals in several oils and fatsGrasas y Aceites, 2004
- Determination of Cadmium, Lead, and Copper in Margarines and Butters by Galvanostatic Stripping ChronopotentiometryJournal of Agricultural and Food Chemistry, 2004
- Nomenclature in evaluation of analytical methods including detection and quantification capabilities1Adapted from the International Union of Pure and Applied Chemistry (IUPAC) document “Nomenclature in Evaluation of Analytical Methods including Detection and Quantification Capabilities”, which originally appeared in Pure and Applied Chemistry, 67 1699–1723 (1995) © 1995 IUPAC. Republication permission granted by IUPAC.1Analytica Chimica Acta, 1999