Yasemin Bakircioglu Kurtulus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yasemin Bakircioglu Kurtulus has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Dilek Bakircioglu
Trakya University, Faculty of Science, Department of Chemistry, Edirne, Turkey
14 shared publications Nukte Topraksever
Trakya University, Faculty of Science, Department of Chemistry , Edirne, Turkey
7 shared publications- Suleyman Akman
Istanbul Technical University, Faculty of Science and Letters, Department of Chemistry, Maslak-Istanbul, Turkey
6 shared publications Selcuk Yurtsever
Trakya University, Faculty of Science, Department of Biology, Edirne, TURKEY
4 shared publicationsDilek Bakircioglu
Trakya University, Faculty of Science, Chemistry Department, Edirne
3 shared publicationsGokhan Ucar
Trakya University, Faculty of Science
2 shared publications
Latest Publications
- 26 April 2022
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 105 (5) , 1299-1308
Extraction Induced by Emulsion Breaking for Ca, Cu, Fe, Mn, Ni, and Zn Determination in Chocolate by Flame Atomic Absorption Spectrometry
Chocolate is a rich source of essential and non-essential elements. A new liquid–liquid extraction (LLE) approach, extraction induced by emulsion breaking (EIEB), is proposed in which the analyzed elements are transferred from the organic phase to the aqueous phase before measurement by flame atomic absorption spectrometry (FAAS). To compare EIEB to microwave digestion (MWD) for extraction of elements from chocolate prior to FAAS. EIEB parameters were varied to optimize the procedure. EIEB-FAAS was then compared to MWD-FAAS for the analysis of Ca, Cu, Fe, Mn, Ni, and Zn in milk and dark chocolate samples. A certified reference material (NIST 2384, baking chocolate) was analyzed to determine the recoveries of Ca, Cu, Fe, Mn, and Zn by the two methods. The optimized EIEB extraction method involves dilution of tempered chocolate with toluene, ultrasonic emulsification with acidified Triton X-114, breaking the emulsion by heating, and centrifugation to produce two well-defined phases. Analysis of dark and milk chocolate samples showed similar repeatability by EIEB-FAAS (RSDr 0.3 to 6.6% in dark and 0.5 to 8.7% in milk) and MWD-FAAS (RSDr 0.5 to 5.4% in dark and 0.7 to 10.2% in milk), with no significant difference detected between the methods for analysis of Ca, Cu, Fe, Mn, Ni, and Zn based on Student’s t-test. Analysis of NIST 2384 baking chocolate certified reference material for Ca, Cu, Fe, Mn, and Zn demonstrated recoveries of 98.6 to 99.5% for EIEB-FAAS compared to 95.8 to 98.6% for MWD-FAAS. EIEB-FAAS was shown to provide high recovery and excellent repeatability for accurate determination of Ca, Cu, Fe, Mn, Ni, and Zn from dark and milk chocolates. The EIEB-FAAS method is simpler and requires fewer reagents compared to other sample preparation methods and allows the calibration to be carried out using aqueous calibration solutions.
- 26 April 2022
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 105 (5) , 1299-1308
Extraction Induced by Emulsion Breaking for Ca, Cu, Fe, Mn, Ni, and Zn Determination in Chocolate by Flame Atomic Absorption Spectrometry
Chocolate is a rich source of essential and non-essential elements. A new liquid–liquid extraction (LLE) approach, extraction induced by emulsion breaking (EIEB), is proposed in which the analyzed elements are transferred from the organic phase to the aqueous phase before measurement by flame atomic absorption spectrometry (FAAS). To compare EIEB to microwave digestion (MWD) for extraction of elements from chocolate prior to FAAS. EIEB parameters were varied to optimize the procedure. EIEB-FAAS was then compared to MWD-FAAS for the analysis of Ca, Cu, Fe, Mn, Ni, and Zn in milk and dark chocolate samples. A certified reference material (NIST 2384, baking chocolate) was analyzed to determine the recoveries of Ca, Cu, Fe, Mn, and Zn by the two methods. The optimized EIEB extraction method involves dilution of tempered chocolate with toluene, ultrasonic emulsification with acidified Triton X-114, breaking the emulsion by heating, and centrifugation to produce two well-defined phases. Analysis of dark and milk chocolate samples showed similar repeatability by EIEB-FAAS (RSDr 0.3 to 6.6% in dark and 0.5 to 8.7% in milk) and MWD-FAAS (RSDr 0.5 to 5.4% in dark and 0.7 to 10.2% in milk), with no significant difference detected between the methods for analysis of Ca, Cu, Fe, Mn, Ni, and Zn based on Student’s t-test. Analysis of NIST 2384 baking chocolate certified reference material for Ca, Cu, Fe, Mn, and Zn demonstrated recoveries of 98.6 to 99.5% for EIEB-FAAS compared to 95.8 to 98.6% for MWD-FAAS. EIEB-FAAS was shown to provide high recovery and excellent repeatability for accurate determination of Ca, Cu, Fe, Mn, Ni, and Zn from dark and milk chocolates. The EIEB-FAAS method is simpler and requires fewer reagents compared to other sample preparation methods and allows the calibration to be carried out using aqueous calibration solutions.
- 8 June 2021
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 15 (1) , 52-64
Investigation of aflatoxin and metal concentrations in animal feeds and feed ingredients from Turkey
The contents of aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1) aflatoxin G2 (AFG2), aluminium (Al), arsenic (As), barium (Ba), calcium (Ca), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), mercury (Hg), potassium (K), magnesium (Mg), manganese (Mn), sodium (Na), nickel (Ni), phosphorus (P), lead (Pb), selenium (Se), tin (Sn) and zinc (Zn) in animal feed samples in Turkey were screened. Eighty animal feeds and feed ingredients were collected from different cities in Turkey. Aflatoxins were determined using the HPLC instrument after pre-separation using immunoaffinity column, and also the instrument of ICP-MS was used for metal determinations. All types of animal feed samples have led concentrations lower than the maximum EU and Turkey regulation limit, while 1.25% and 11.8 of mixed and feed additive samples had AFB1 and Hg concentrations higher than the maximum limits, respectively. A single correlation analysis was used to determine the relationship between AFB1 and total AFs and metal contents in mixed animal feed samples (p<0.05). A strong positive correlation was found between As and AFB1 and total AFs contents; whereas Cr was correlated negatively to AFB1 and total AFs, using single correlation analyses.
- 8 June 2021
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 15 (1) , 52-64
Investigation of aflatoxin and metal concentrations in animal feeds and feed ingredients from Turkey
The contents of aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1) aflatoxin G2 (AFG2), aluminium (Al), arsenic (As), barium (Ba), calcium (Ca), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), mercury (Hg), potassium (K), magnesium (Mg), manganese (Mn), sodium (Na), nickel (Ni), phosphorus (P), lead (Pb), selenium (Se), tin (Sn) and zinc (Zn) in animal feed samples in Turkey were screened. Eighty animal feeds and feed ingredients were collected from different cities in Turkey. Aflatoxins were determined using the HPLC instrument after pre-separation using immunoaffinity column, and also the instrument of ICP-MS was used for metal determinations. All types of animal feed samples have led concentrations lower than the maximum EU and Turkey regulation limit, while 1.25% and 11.8 of mixed and feed additive samples had AFB1 and Hg concentrations higher than the maximum limits, respectively. A single correlation analysis was used to determine the relationship between AFB1 and total AFs and metal contents in mixed animal feed samples (p<0.05). A strong positive correlation was found between As and AFB1 and total AFs contents; whereas Cr was correlated negatively to AFB1 and total AFs, using single correlation analyses.
- 28 February 2020
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 103 (5) , 1256-1263
Extraction of Cu, Fe, Mn, and Ni from Margarine Samples Using Extraction Induced by Emulsion Breaking Procedure Prior to Graphite Furnace Atomic Absorption Spectrometry and Comparison of Results to Provisional Tolerable Daily Intake Values
Background: The emulsion induced by emulsion breaking (EIEB) procedure was previously reported for the extraction of copper, iron, manganese, and nickel from liquid oil samples such as vegetable oil. Objective: To optimize the EIEB procedure for determination of copper, iron, manganese, and nickel in solid oil (margarine) samples by Graphite Furnace Atomic Absorption Spectrometry (GFAAS). Methods: The extraction procedure uses a surfactant in nitric acid to form an emulsion followed by heating to break the emulsion. Optimization included variation of the test portion size, the type and concentration of the surfactant, the concentration of nitric acid in the aqueous solution, the emulsion agitation time, heating temperature, and the time required to break the emulsion. Results: Mean element concentrations of 11 margarine samples were in the following ranges: Cu 0.031–0.131 µg/g, Fe 5.7–24.9 µg/g, Mn 0.542–1.11 µg/g, and Ni 0.108–0.134 µg/g. Under the optimized extraction conditions, the detection limits (µg/kg) were 4.8, 13, 1.5, and 23 for Cu, Fe, Mn, and Ni, respectively. The accuracy of the extraction procedure was determined by comparison to commonly used microwave digestion procedure. The EIEB results were not statistically different from the microwave digestion results when analyzed by GFAAS as determined by the statistical tests. Conclusions: The EIEB procedure was shown to be equivalent to the commonly used microwave digestion procedure for extraction of analytes from margarine samples. Highlights: The optimized EIEB extraction procedure is simple, rapid, low cost, and environmentally friendly. It has improved detection limits and allows calibration with aqueous standards.
- 28 February 2020
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 103 (5) , 1256-1263
Extraction of Cu, Fe, Mn, and Ni from Margarine Samples Using Extraction Induced by Emulsion Breaking Procedure Prior to Graphite Furnace Atomic Absorption Spectrometry and Comparison of Results to Provisional Tolerable Daily Intake Values
Background: The emulsion induced by emulsion breaking (EIEB) procedure was previously reported for the extraction of copper, iron, manganese, and nickel from liquid oil samples such as vegetable oil. Objective: To optimize the EIEB procedure for determination of copper, iron, manganese, and nickel in solid oil (margarine) samples by Graphite Furnace Atomic Absorption Spectrometry (GFAAS). Methods: The extraction procedure uses a surfactant in nitric acid to form an emulsion followed by heating to break the emulsion. Optimization included variation of the test portion size, the type and concentration of the surfactant, the concentration of nitric acid in the aqueous solution, the emulsion agitation time, heating temperature, and the time required to break the emulsion. Results: Mean element concentrations of 11 margarine samples were in the following ranges: Cu 0.031–0.131 µg/g, Fe 5.7–24.9 µg/g, Mn 0.542–1.11 µg/g, and Ni 0.108–0.134 µg/g. Under the optimized extraction conditions, the detection limits (µg/kg) were 4.8, 13, 1.5, and 23 for Cu, Fe, Mn, and Ni, respectively. The accuracy of the extraction procedure was determined by comparison to commonly used microwave digestion procedure. The EIEB results were not statistically different from the microwave digestion results when analyzed by GFAAS as determined by the statistical tests. Conclusions: The EIEB procedure was shown to be equivalent to the commonly used microwave digestion procedure for extraction of analytes from margarine samples. Highlights: The optimized EIEB extraction procedure is simple, rapid, low cost, and environmentally friendly. It has improved detection limits and allows calibration with aqueous standards.
- 25 February 2018
- Published by Atomic Spectroscopy Press Limited in Atomic Spectroscopy
- Vol. 39 (01) , 38-45
ICP-OES Determination of Some Trace Elements in Herbal Oils Using a Three-Phase Emulsion Method and Comparison with Conventional Methods
- 25 February 2018
- Published by Atomic Spectroscopy Press Limited in Atomic Spectroscopy
- Vol. 39 (01) , 38-45
ICP-OES Determination of Some Trace Elements in Herbal Oils Using a Three-Phase Emulsion Method and Comparison with Conventional Methods
- 1 September 2017
- Published by Oxford University Press (OUP)
- Vol. 100 (5) , 1531-1538
Determination of Several Element Levels in Hardaliye Beverages Using Flame Atomic Absorption Spectrometry After Ultrasound-Probe Extraction
In the present study, concentrations of calcium (Ca), copper (Cu), magnesium (Mg), manganese (Mn), sodium (Na), and zinc (Zn) in hardaliye samples produced in Turkey were determined by flame atomic absorption spectrometry after ultrasound probe extraction (UPE), microwave-assisted extraction (MAE), and wet extraction procedures. At present, there is limited work in the literature on UPE for the determination of trace elements in beverage samples. Our single-correlation analysis showed that the elements studied with the UPE method in hardaliye were strongly correlated with the MAE procedure. The parameters affecting the UPE experimental conditions—such as ultrasound amplitude, sonication time, sample amount, extractant type, and volume—were studied. Optimal experimental conditions for the extraction of the metals with the UPE procedure were as follows: 2 min of sonication; 30% amplitude; 3 mL sample volume;5% HNO3 extraction solution; and 1 mL extractant volume for Ca, Cu, Mg, Mn, Na, and Zn in thehardaliye samples. The results in the hardaliye samples in minimum–maximum mg/L with the UPE procedure were 33–63 for Ca, 0.10–0.27 forCu, 3.9–14.4 for Mg, 1.0–3.2 for Mn,32–58 for Na, and 0.39–1.1 for Zn. LODs were 0.0032, 0.012, 0.013, 0.009, 0.011, and 0.008 mg/L for Ca, Cu, Mg, Mn, Na, and Zn, respectively. The accuracy of the method was verified with a recovery test (in which recoveries between 95 and 110% wereobserved) and application to a NIST 1643e certified sample (trace elements in water). The UPE procedure was found to be fast, accurate, and simple, with fewer contaminants and lower concentrated reagent consumption in comparison with conventional extraction procedures.
- 1 September 2017
- Published by Oxford University Press (OUP)
- Vol. 100 (5) , 1531-1538
Determination of Several Element Levels in Hardaliye Beverages Using Flame Atomic Absorption Spectrometry After Ultrasound-Probe Extraction
In the present study, concentrations of calcium (Ca), copper (Cu), magnesium (Mg), manganese (Mn), sodium (Na), and zinc (Zn) in hardaliye samples produced in Turkey were determined by flame atomic absorption spectrometry after ultrasound probe extraction (UPE), microwave-assisted extraction (MAE), and wet extraction procedures. At present, there is limited work in the literature on UPE for the determination of trace elements in beverage samples. Our single-correlation analysis showed that the elements studied with the UPE method in hardaliye were strongly correlated with the MAE procedure. The parameters affecting the UPE experimental conditions—such as ultrasound amplitude, sonication time, sample amount, extractant type, and volume—were studied. Optimal experimental conditions for the extraction of the metals with the UPE procedure were as follows: 2 min of sonication; 30% amplitude; 3 mL sample volume;5% HNO3 extraction solution; and 1 mL extractant volume for Ca, Cu, Mg, Mn, Na, and Zn in thehardaliye samples. The results in the hardaliye samples in minimum–maximum mg/L with the UPE procedure were 33–63 for Ca, 0.10–0.27 forCu, 3.9–14.4 for Mg, 1.0–3.2 for Mn,32–58 for Na, and 0.39–1.1 for Zn. LODs were 0.0032, 0.012, 0.013, 0.009, 0.011, and 0.008 mg/L for Ca, Cu, Mg, Mn, Na, and Zn, respectively. The accuracy of the method was verified with a recovery test (in which recoveries between 95 and 110% wereobserved) and application to a NIST 1643e certified sample (trace elements in water). The UPE procedure was found to be fast, accurate, and simple, with fewer contaminants and lower concentrated reagent consumption in comparison with conventional extraction procedures.
- 1 May 2014
- Published by Elsevier in Food Chemistry
- Vol. 151, 219-224
Determination of zinc in edible oils by flow injection FAAS after extraction induced by emulsion breaking procedure
- 1 May 2014
- Published by Elsevier in Food Chemistry
- Vol. 151, 219-224
Determination of zinc in edible oils by flow injection FAAS after extraction induced by emulsion breaking procedure
- 25 April 2014
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 69 (5) , 420-425
Determination of metal ions in water and tea samples by flame-AAS after preconcentration using sorghum in nature form and chemically activated
Sorghum-agricultural waste in nature (SAWN) and chemically activated with phosphoric acid (SAWAC) was used as a solid phase extraction material for determination of cadmium, copper, manganese and lead ions in aqueous solutions by flame atomic absorption spectrometry (FAAS). The effect of pH, sample flow rate and volume, eluent type, volume and flow rate, and the effects of potentially interfering ions on the recovery of the analytes were investigated. Adsorption capacity of SAWN and SAWAC was determined by batch method under the optimized conditions. Adsorption capacity of SAWAC was found to be 9.53, 11.77, 11.64, and 15.01 mg/L for Cd, Cu, and Mn and Pb ions, respectively. The limit of detection (LOD) for the analytes was found in the range of 0.16–1.21 μg/L with a theoretical preconcentration factor of 50. The method was validated by analyzing certified material (GBW 07605-Tea) and the results were in a good agreement with the certified value. In addition, the proposed method was applied to the determination of analytes in tea and river water samples.
- 25 April 2014
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 69 (5) , 420-425
Determination of metal ions in water and tea samples by flame-AAS after preconcentration using sorghum in nature form and chemically activated
Sorghum-agricultural waste in nature (SAWN) and chemically activated with phosphoric acid (SAWAC) was used as a solid phase extraction material for determination of cadmium, copper, manganese and lead ions in aqueous solutions by flame atomic absorption spectrometry (FAAS). The effect of pH, sample flow rate and volume, eluent type, volume and flow rate, and the effects of potentially interfering ions on the recovery of the analytes were investigated. Adsorption capacity of SAWN and SAWAC was determined by batch method under the optimized conditions. Adsorption capacity of SAWAC was found to be 9.53, 11.77, 11.64, and 15.01 mg/L for Cd, Cu, and Mn and Pb ions, respectively. The limit of detection (LOD) for the analytes was found in the range of 0.16–1.21 μg/L with a theoretical preconcentration factor of 50. The method was validated by analyzing certified material (GBW 07605-Tea) and the results were in a good agreement with the certified value. In addition, the proposed method was applied to the determination of analytes in tea and river water samples.
- 1 June 2013
- Published by Elsevier in Food Chemistry
- Vol. 138 (2-3) , 770-775
Comparison of extraction induced by emulsion breaking, ultrasonic extraction and wet digestion procedures for determination of metals in edible oil samples in Turkey using ICP-OES
- 1 June 2013
- Published by Elsevier in Food Chemistry
- Vol. 138 (2-3) , 770-775
Comparison of extraction induced by emulsion breaking, ultrasonic extraction and wet digestion procedures for determination of metals in edible oil samples in Turkey using ICP-OES