A new approach to the continuous monitoring of transvenous lead extraction using transesophageal echocardiography—Analysis of 936 procedures
Authors:
- 10 March 2020
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 37 (4) , 601-611
Abstract
Aims: The usefulness of transesophageal echocardiographic (TEE) monitoring for transvenous lead extraction (TLE) procedures is still controversial. The purpose of the current study was to present new TEE values in detecting invisible events in fluoroscopy and preventing the development of dangerous complications.Methods: From 2015 to 2019, a total of 1026 procedures were performed in single TLE center. In total, 1108 leads had been extracted with a mean lead dwell time of 115.8 ± 77.6 months. Continuous TEE was used in 936 patients with a mean age of 67.1 ± 14.4 years.Results: Preprocedure examination revealed looped leads in 181 (19.3%) patients, dry cardiac perforation in 151 (16.1%), lead‐to‐lead adhesion in 172 (18.4%), lead adhesion to the myocardium in 317 (33.9%), and vegetations in 119 (12.7%) patients. Intra‐procedural TEE demonstrated pulling on the atrial wall, ventricular wall, or tricuspid valve in 380 (40.5%), 235 (25.1%), and 78 (8.3%) patients, respectively. Acute tamponade requiring sternotomy occurred in 11 (1.1%) patients. Migration of vegetation or connective tissue fragments were seen in 69 (7.3%) and 111 (11.8%) patients, respectively. After procedure, TEE was helpful in navigating an implantation, a new lead in 97 (10.3%) patients, and removing the remnants of lead/silicone insulation in 50 (5.3%) patients.Conclusion: Real time transesophageal echocardiography for the guidance of transvenous lead extraction informs the operator about the danger of manipulations close to delicate cardiac structures and whether immediate modification to the plan of lead removal is necessary in order to prevent the occurrence of unwanted events.Keywords
This publication has 24 references indexed in Scilit:
- Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paperEP Europace, 2011
- Prevalence of tricuspid regurgitation and pericardial effusions following pacemaker and defibrillator lead extractionInternational Journal of Cardiology, 2010
- Lead Extraction in the Contemporary Setting: The LExICon StudyJACC, 2010
- Incidence, Risk Factors, and Outcome of Traumatic Tricuspid Regurgitation After Percutaneous Ventricular Lead RemovalJACC, 2009
- Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leadsEuropean Heart Journal, 2008
- Residual fibrous tissue floating in the right atrium after percutaneous pacemaker lead extraction: An unusual complication early detected by intracardiac echocardiographyInternational Journal of Cardiology, 2008
- Clinical Utility of Intraprocedural Transesophageal Echocardiography during Transvenous Lead ExtractionJournal of the American Society of Echocardiography, 2008
- Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indicationsHeart Rhythm, 2008
- Laser Lead Extraction: Predictors of Success and ComplicationsPacing and Clinical Electrophysiology, 2007
- Recommendations for Extraction of Chronically Implanted Transvenous Pacing and Defibrillator Leads: Indications, Facilities, TrainingPacing and Clinical Electrophysiology, 2000