Abstract
Objectives: The aim of this study was to assess, using the CDR Wireless®, the effect of different exposure times on caries detection and pixel intensity values. Materials and Methods: Forty teeth were x-rayed using a Schick CDR Wireless sensor at eight different exposure times – 0.06, 0.10, 0.13, 0.16, 0.20, 0.25, 0.30, and 0.32 s. Four observers evaluated the images for presence of carious lesions scoring proximal surfaces of each tooth on a 5-point scale. Scores were compared to histological sections of the teeth. Accuracy was evaluated by means of ROC curve analysis. Radiographs of an aluminum step wedge were obtained using the same eight exposure times. Pixel intensity measurements were obtained, and mean pixel values were statistically analyzed using linear regression. Results: The Az for each exposure time varied from 0.53 to 0.62. Two-way analysis of variance and Tukey test demonstrated that the exposure time of 0.25 s presented the best result and was significantly higher than 0.30 s and 0.35 s. In regard to mean pixel values, two different behaviors were observed, and the exposure time of 0.20 s presented mean pixel values in both phases. Conclusion: The performance of the exposure times from 0.06 s to 0.25 s was satisfactory for proximal caries detection, and 0.25 s is the best as indicated for this finality. Clinical Relevance: Considering that a reduction of exposure time represents a reduction of patient exposure dose, and this reduction cannot neglect image quality, the behavior of any digital system must be carefully evaluated.Keywords
This publication has 21 references indexed in Scilit:
- Rating the extent of surface scratches on photostimulable storage phosphor plates in a dental school environmentDentomaxillofacial Radiology, 2010
- Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-specific enhancement filters. An ex vivo study in human teethClinical Oral Investigations, 2008
- A comparison of older and newer versions of intraoral digital radiography systemsThe Journal of the American Dental Association, 2007
- Grey-scale reversed radiographic display in the detection of approximal cariesJournal of Dentistry, 2005
- Comparison of complementary metal oxide semiconductor and charge-coupled device intraoral X-ray detectors using subjective image qualityDentomaxillofacial Radiology, 2003
- Accuracy of caries detection with four storage phosphor systems and E-speed radiographsDentomaxillofacial Radiology, 2002
- Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systemsDentomaxillofacial Radiology, 2002
- Conventional, Digital and Contrast–Enhanced Bitewing Radiographs in the Decision to Restore Approximal Carious LesionsCaries Research, 2001
- Detection of caries with conventional digital imaging and tuned aperture computed tomography using CRT monitor and laptop displaysOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1999
- Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems: an in vitro study.Dentomaxillofacial Radiology, 1995