A novel photomultiplier tube neutron time-of-flight detector
- 1 January 2021
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (1) , 013509
Abstract
A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. In DT implosions with neutron yield larger than 1013, a novel detector consisting of a microchannel-plate (MCP) photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signals in PMT nTOF detectors are produced from neutron interaction with a PMT window. The direct interaction of neutrons with the MCP provides negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF detector faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOF detectors were deployed in the OMEGA laser system for the first time to diagnose inertial confinement fusion plasma. The design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.Keywords
Funding Information
- Department of Energy National Nuclear Security Administration (DE-NA0003856)
This publication has 10 references indexed in Scilit:
- A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGANuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020
- Calibration of a neutron time-of-flight detector with a rapid instrument response function for measurements of bulk fluid motion on OMEGAReview of Scientific Instruments, 2018
- Testing a Cherenkov neutron time-of-flight detector on OMEGAReview of Scientific Instruments, 2018
- A fused silica Cherenkov radiator for high precision time-of-flight measurement of DT γ and neutron spectra (invited)Review of Scientific Instruments, 2018
- Area and extraction field analysis of the analogue saturation of 40 mm microchannel plate photomultiplier tubesReview of Scientific Instruments, 2018
- Analysis of the neutron time-of-flight spectra from inertial confinement fusion experimentsJournal of Applied Physics, 2015
- The National Ignition Facility neutron time-of-flight system and its initial performance (invited)Review of Scientific Instruments, 2010
- Prototypes of National Ignition Facility neutron time-of-flight detectors tested on OMEGAReview of Scientific Instruments, 2004
- Wide-dynamic-range “neutron bang time” detector on OMEGAReview of Scientific Instruments, 2002
- Interpretation of neutron time-of-flight signals from current-mode detectorsReview of Scientific Instruments, 1997