Abstract
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The single screw-plate interfaces of the VA-LCP showed the highest bending moment at an angle of 0° and 5°, the IXOS® P4 at an angle of 10° and 15° and the VariAX™ when changing the insertion angle from 10° into 5°. The strength of polyaxial locking interfaces and mechanism of failure proved to be different among the examined plates.Keywords
This publication has 7 references indexed in Scilit:
- Evaluation of a polyaxial angle-stable volar plate in a distal radius C-fracture model – A biomechanical studyInjury, 2011
- Does a Volar Locking Plate Provide Equivalent Stability as a Dorsal Nonlocking Plate in a Dorsally Comminuted Distal Radius Fracture?Journal of Orthopaedic Trauma, 2008
- Prospective Study of Distal Radius Fractures Treated With a Volar Locking Plate SystemThe Journal of Hand Surgery, 2008
- A Biomechanical Comparison of Two Volar Locked Plates in a Dorsally Unstable Distal Radius Fracture Model2006
- Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patientThe Journal of Hand Surgery, 2004
- Volar fixation for dorsally displaced fractures of the distal radius: A preliminary reportThe Journal of Hand Surgery, 2002
- Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius: A brief reportThe Journal of Hand Surgery, 1998