Latest Publications
- 17 August 2013
- Published by Springer Nature in Der Unfallchirurg
- Vol. 117 (2) , 138-144
Versorgung von Fingerfrakturen mit der Minihakenplatte
- 17 August 2013
- Published by Springer Nature in Der Unfallchirurg
- Vol. 117 (2) , 138-144
Versorgung von Fingerfrakturen mit der Minihakenplatte
- 6 February 2013
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 38 (7) , 751-757
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and correction was done immediately. C-arm CT imaging can easily be integrated in the normal course of surgery. As a complement to the standard 2D-fluoroscopy, the C-arm CT is a useful tool to evaluate the quality of osteosynthesis.
- 6 February 2013
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 38 (7) , 751-757
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and correction was done immediately. C-arm CT imaging can easily be integrated in the normal course of surgery. As a complement to the standard 2D-fluoroscopy, the C-arm CT is a useful tool to evaluate the quality of osteosynthesis.
- 10 January 2013
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 39 (2) , 139-146
Nailing versus plating for comminuted fractures of the distal femur: a comparative biomechanical in vitro study of three implants
The purpose of our study was to determine the biomechanical properties of three different implants utilized for internal fixation of a supracondylar femur fracture. The retrograde supracondylar nail (SCN), the less invasive stabilization system plate (LISS) and the distal femoral nail (DFN) were tested and their biomechanical properties compared. Twenty pairs of fresh-frozen human femura were used. Each femur was osteotomised to simulate a comminuted supracondylar fracture (AO/OTA 33.A3) and then randomized to fracture fixation with either SCN (n=9) or LISS (n=9). Each contralateral femur was stabilized with DFN as a control (n=18). Two femur pairs were spent on pretesting. All femura were subjected to axial (10–500 N) and torsional (0.1–14 Nm) loading. Eighteen matched femur pairs were analyzed. The post-loading median residual values were 49.78, 41.25 and 33.51% of the axial stiffness of the intact femur and 59.04, 62.37 and 46.72% of the torsional stiffness of the intact femur in the SCN, LISS and DFN groups. There were no significant differences between the three implants concerning axial and torsional stiffness. All implants had sufficient biomechanical stability under physiological torsional and axial loading. All three implants have different mechanisms for distal locking. The SCN nail with the four-screw distal interlocking had the best combined axial and torsional stiffness whereas the LISS plate had the highest torsional stiffness.
- 10 January 2013
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 39 (2) , 139-146
Nailing versus plating for comminuted fractures of the distal femur: a comparative biomechanical in vitro study of three implants
The purpose of our study was to determine the biomechanical properties of three different implants utilized for internal fixation of a supracondylar femur fracture. The retrograde supracondylar nail (SCN), the less invasive stabilization system plate (LISS) and the distal femoral nail (DFN) were tested and their biomechanical properties compared. Twenty pairs of fresh-frozen human femura were used. Each femur was osteotomised to simulate a comminuted supracondylar fracture (AO/OTA 33.A3) and then randomized to fracture fixation with either SCN (n=9) or LISS (n=9). Each contralateral femur was stabilized with DFN as a control (n=18). Two femur pairs were spent on pretesting. All femura were subjected to axial (10–500 N) and torsional (0.1–14 Nm) loading. Eighteen matched femur pairs were analyzed. The post-loading median residual values were 49.78, 41.25 and 33.51% of the axial stiffness of the intact femur and 59.04, 62.37 and 46.72% of the torsional stiffness of the intact femur in the SCN, LISS and DFN groups. There were no significant differences between the three implants concerning axial and torsional stiffness. All implants had sufficient biomechanical stability under physiological torsional and axial loading. All three implants have different mechanisms for distal locking. The SCN nail with the four-screw distal interlocking had the best combined axial and torsional stiffness whereas the LISS plate had the highest torsional stiffness.
- 1 January 2013
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 58 (2) , 187-94
Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable distal radius plates
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The single screw-plate interfaces of the VA-LCP showed the highest bending moment at an angle of 0° and 5°, the IXOS® P4 at an angle of 10° and 15° and the VariAX™ when changing the insertion angle from 10° into 5°. The strength of polyaxial locking interfaces and mechanism of failure proved to be different among the examined plates.
- 1 January 2013
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 58 (2) , 187-94
Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable distal radius plates
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The single screw-plate interfaces of the VA-LCP showed the highest bending moment at an angle of 0° and 5°, the IXOS® P4 at an angle of 10° and 15° and the VariAX™ when changing the insertion angle from 10° into 5°. The strength of polyaxial locking interfaces and mechanism of failure proved to be different among the examined plates.