Absolute dose calculations for Monte Carlo simulations of radiotherapy beams
Authors:
- I A PopescuIPI A Popescu
- C P ShawCSC P Shaw
- S F ZavgorodniSZS F Zavgorodni
- W A BeckhamWBW A Beckham
- 6 July 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (14) , 3375-3392
Abstract
Monte Carlo (MC) simulations have traditionally been used for single field relative comparisons with experimental data or commercial treatment planning systems (TPS). However, clinical treatment plans commonly involve more than one field. Since the contribution of each field must be accurately quantified, multiple field MC simulations are only possible by employing absolute dosimetry. Therefore, we have developed a rigorous calibration method that allows the incorporation of monitor units (MU) in MC simulations. This absolute dosimetry formalism can be easily implemented by any BEAMnrc/DOSXYZnrc user, and applies to any configuration of open and blocked fields, including intensity-modulated radiation therapy (IMRT) plans. Our approach involves the relationship between the dose scored in the monitor ionization chamber of a radiotherapy linear accelerator (linac), the number of initial particles incident on the target, and the field size. We found that for a 10 x 10 cm2 field of a 6 MV photon beam, 1 MU corresponds, in our model, to 8.129 x 10(13) +/- 1.0% electrons incident on the target and a total dose of 20.87 cGy +/- 1.0% in the monitor chambers of the virtual linac. We present an extensive experimental verification of our MC results for open and intensity-modulated fields, including a dynamic 7-field IMRT plan simulated on the CT data sets of a cylindrical phantom and of a Rando anthropomorphic phantom, which were validated by measurements using ionization chambers and thermoluminescent dosimeters (TLD). Our simulation results are in excellent agreement with experiment, with percentage differences of less than 2%, in general, demonstrating the accuracy of our Monte Carlo absolute dose calculations.Keywords
This publication has 26 references indexed in Scilit:
- Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MVMedical Physics, 2004
- Modelling an extreme water–lung interface using a single pencil beam algorithm and the Monte Carlo methodPhysics in Medicine & Biology, 2004
- Summary and recommendations of a National Cancer Institute workshop on issues limiting the clinical use of Monte Carlo dose calculation algorithms for megavoltage external beam radiation therapyMedical Physics, 2003
- Reply to `Comments on `Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams' 'Physics in Medicine & Biology, 2003
- Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX acceleratorPhysics in Medicine & Biology, 2002
- Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantomMedical Physics, 2001
- Photon dose calculation of a three‐dimensional treatment planning system compared to the Monte Carlo code BEAMMedical Physics, 2000
- Backscatter into the beam monitor chamber: Implications for dosimetry of asymmetric collimatorsMedical Physics, 1993
- The effect of collimator backscatter radiation on photon output of linear acceleratorsMedical Physics, 1987