Accuracy of the Garmin Vivoactive 4 for Estimating Heart Rate, Energy Expenditure, and Step Count During Treadmill Exercise
Authors:
Preprint
- 6 January 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
The purpose of this study was to examine the validity of a Garmin wrist-based device for estimating heart rate, energy expenditure, and step count during incremental treadmill exercise in college-aged individuals. Eighteen males and females (mean ± SD age = 23.2 ± 4.9 years) volunteered to complete an incremental treadmill test with the Garmin Vivoactive 4 device and criterion methods (electrocardiogram, indirect calorimetry, and video recording) measuring heart rate, energy expenditure, and step count. Mean absolute percent error (MAPE), simple linear regression, and Bland-Altman plots were used to assess accuracy. Acceptable accuracy was defined as MAPE < 5% for heart rate and < 10% for energy expenditure and step count. Statistical significance was set at α < 0.05. The MAPE (±SD) values were 13.0 (±10.1), 19.1 (±15.0), and 4.6 (±5.3)% for heart rate, energy expenditure, and step count, respectively. The Bland-Altman regression analyses illustrated proportional bias was present for estimations of heart rate (r = 0.591, p < 0.001) and step count (r = 0.516, p = 0.028), but not energy expenditure (r = 0.351, p = 0.153). These findings indicated that the Garmin Vivoactive 4 provided acceptable accuracy metrics for step count, but not heart rate or energy expenditure.Keywords
All Related Versions
- Version 1, 2026-01-06, Preprints
- Published version: Applied Sciences, 16 (3), 1286.
This publication has 42 references indexed in Scilit:
- Validity of Four Consumer‐Grade Optical Heart Rate Sensors for Assessing Volume and Intensity Distribution of Physical ActivityScandinavian Journal of Medicine & Science in Sports, 2024
- Accuracy of smartwatches for the remote assessment of exercise capacityScientific Reports, 2024
- Keeping Pace with Wearables: A Living Umbrella Review of Systematic Reviews Evaluating the Accuracy of Consumer Wearable Technologies in Health MeasurementSports Medicine, 2024
- Heart rate processing algorithms and exercise duration on reliability and validity decisions in biceps-worn Polar Verity Sense and OH1 wearablesScientific Reports, 2023
- Validation of Garmin and Polar Devices for Continuous Heart Rate Monitoring During Common Training Movements in Tactical PopulationsMeasurement in Physical Education and Exercise Science, 2022
- Wrist‐worn devices for the measurement of heart rate and energy expenditure: A validation study for the Apple Watch 6, Polar Vantage V and Fitbit SenseEuropean Journal of Sport Science, 2022
- Toward Harmonized Treadmill-Based Validation of Step-Counting Wearable Technologies: A Scoping ReviewJournal of Physical Activity and Health, 2020
- Accuracy of the wearable activity tracker Garmin Forerunner 235 for the assessment of heart rate during rest and activityJournal of Sports Sciences, 2018
- Do activity monitors increase physical activity in adults with overweight or obesity? A systematic review and meta‐analysisObesity, 2016
- Personalizing energy expenditure estimation using physiological signals normalization during activities of daily livingPhysiological Measurement, 2014